Design of Wood Diaphragms with Openings
Publication: Journal of Structural Engineering
Volume 124, Issue 7
Abstract
The existence of openings in diaphragms causes concentration of shear forces around the openings and the generation of axial forces in the framing. In 1981, the Applied Technology Council developed the only guidelines for designing diaphragms with openings. The procedure for determining the shear around the opening, however, is complicated and has not been experimentally verified. Accordingly, simplified equations for determining the shear forces in diaphragms with openings are derived in this paper. The application of the membrane-to-brace replacement method to diaphragms is also discussed. Horizontal loading tests are conducted on three floor diaphragms designed to the same load. The ultimate loads are almost the same, regardless of the existence of the opening. The observed unit shear around the opening is close to the calculated value. The observed deflection is smaller than the value calculated on the basis of the nominal stiffness for the materials and the fasteners by 14–28%. It can be said from these results that all the methods perform well as a practical design tool.
Get full access to this article
View all available purchase options and get full access to this article.
References
1.
Countryman, D. (1952). “Lateral test on plywood sheathed diaphragms.”Lab. Rep. 55, Douglas Fir Plywood Association, Tacoma, Wash.
2.
Countryman, D., and Colbenson, P. (1955). “Horizontal plywood diaphragm tests.”Lab. Rep. 63, Douglas Fir Plywood Association, Tacoma, Wash.
3.
Diekmann, E. F. (1986). Design of wood diaphragms, Volume IV: Clark C. Heritage memorial series on wood, Pennsylvania State University, University Park, Pa.
4.
Diekmann, E. F. (1989). “Wood shearwalls for engineers.”Proc., Pacific Timber Eng. Conf. 1989, Auckland, New Zealand, 263–267.
5.
Diekmann, E. F. (1995). “Chapter 8: diaphragms and shearwalls.”Wood engineering and construction handbook. McGraw-Hill, Inc., New York, N.Y., 8.1–8.78.
6.
Falk, R. H., and Itani, R. Y. (1988). “Prediction of diaphragm displacement.”Proc., 1988 Int. Conf. on Timber Engrg., Seattle, Wash., 766–773.
7.
Guidelines for the design of horizontal wood diaphragms. (1981). Applied Technology Council, Berkeley, Calif.
8.
Kamiya, F. (1990). “Horizontal plywood sheathed diaphragms with openings: static loading tests and analysis.”Proc., 1990 Int. Timber Engrg. Conf., Tokyo, Japan, 502–509.
9.
Kamiya, F., et al. (1992). “Study on horizontal diaphragms.”Proc., Annual Meeting of the Architectural Inst., Architectural Inst. of Japan, Tokyo, Japan, 97–114 (in Japanese).
10.
Noguchi, H., et al. (1988). “Behavior of diaphragms with openings subjected to horizontal load.”Proc., Annual Meeting of the Architectural Inst., Architectural Inst. of Japan, Tokyo, Japan, 49–50 (in Japanese).
11.
Standard for structural calculation of timber structures. (1988). Architectural Institute of Japan, Tokyo, Japan.
12.
Tissell, J. R. (1967). “1996 horizontal plywood diaphragm tests.”APA Lab. Rep. 106, American Plywood Association, Tacoma, Wash.
13.
Tissell, J. R., and Elliott, J. R. (1981). “Plywood diaphragms.”APA Res. Rep. 138, American Plywood Association, Tacoma, Wash.
14.
Tissell, J. R., and Rose, J. D. (1988). “Plywood end shear walls in mobile homes.”APA Res. Rep. 151, American Plywood Association, Tacoma, Wash.
Information & Authors
Information
Published In
Copyright
Copyright © 1998 American Society of Civil Engineers.
History
Published online: Jul 1, 1998
Published in print: Jul 1998
Authors
Metrics & Citations
Metrics
Citations
Download citation
If you have the appropriate software installed, you can download article citation data to the citation manager of your choice. Simply select your manager software from the list below and click Download.