Seismic Strengthening of Liquid-Storage Tanks with Energy-Dissipating Anchors
Publication: Journal of Structural Engineering
Volume 124, Issue 4
Abstract
The seismic performance of liquid-storage steel tanks can be improved by anchoring them to their foundations with energy-dissipating devices rather than with conventional anchors. Case studies of two tanks are presented—one broad and one slender tank, both anchored with torsional-beam steel dampers, which dissipate seismic energy by inelastic deformations induced by uplifting of the tank wall. Numerical results show that tanks anchored with steel dampers experience significantly less foundation overturning moment than similar fully anchored tanks. Relative to unanchored tanks, the tanks anchored with steel dampers experience small values of base uplift, plastic rotation at the plate boundary, hoop stress in the wall, and radial separation between the plate and foundation. In general, tanks anchored with dampers exhibit performance superior to that of similar unanchored or fully anchored tanks. Due to savings in the material of tank wall, foundation, and full base anchorage, the use of energy dissipating anchors is likely to be cost-effective.
Get full access to this article
View all available purchase options and get full access to this article.
References
1.
API. (1993). “Welded steel tanks for oil storage.”API Standard 650, 9th Ed., Am. Petroleum Inst., Washington, D.C.
2.
AWWA. (1996). “Welded steel tanks for water storage.”AWWA D100. Am. Water Works Assn., Denver, Colo.
3.
Chopra, A. K. (1995). Dynamics of structures: Theory and applications to earthquake engineering. Prentice Hall, Inc., Englewood Cliffs, N.J.
4.
Clough, R. W., and Penzien, J. (1993). Dynamics of structures, 2nd Ed., McGraw-Hill Inc., New York, N.Y.
5.
Cooper, T. W. (1997). “A study of the performance of petroleum storage tanks during earthquakes, 1933–1995.”NIST GCR 97-720, National Inst. of Standards and Technol., Gaithersburg, Md.
6.
Darragh, R., Cao, T., Cramer, C., Huang, M., and Shakal, A. (1994). “Processed CSMIP strong-motion records from the Northridge, California, earthquake of January 17, 1994.”OSMS 94-06A, Calif. Strong Motion Instrumentation Prog., Sacramento, Calif.
7.
Gates, W. E. (1980). “Elevated and ground-supported steel storage tanks, reconnaissance report, Imperial County, California, earthquake of October 15, 1979.” Earthquake Engrg. Res. Inst., Oakland, Calif., 65–73.
8.
Hanson, R. D. (1977). “Behavior of liquid storage tanks, the Great Alaska Earthquake of 1964.” Nat. Academy of Sci., Washington, D.C., 331–339.
9.
Haroun, M. A.(1983). “Behavior of unanchored oil storage tanks: Imperial Valley earthquake.”J. Tech. Topics in Civ. Engrg., ASCE, 109(1), 23–40.
10.
Kelly, T. E., and Mayes, R. L. (1989). “Seismic isolation of storage tanks.”Proc., Sessions Related to Seismic Engrg. at Structures Congress '89, C. A. Kircher and A. K. Chopra, eds., ASCE, Reston, Va., 408–417.
11.
Malhotra, P. K.(1995). “Base uplifting analysis of flexibly-supported liquid-storage tanks.”J. Earthquake Engrg. Struct. Dyn., 24(12), 1591–1607.
12.
Malhotra, P. K.(1997a). “Method for seismic base isolation of liquid-storage tanks.”J. Struct. Engrg., ASCE, 123(1), 113–116.
13.
Malhotra, P. K.(1997b). “Seismic response of soil-supported unanchored liquid-storage tanks.”J. Struct. Engrg., ASCE, 123(4), 440–450.
14.
Malhotra, P. K.(1997c). “New method for seismic isolation of liquid-storage tanks.”J. Earthquake Engrg. Struct. Dyn., 26(8), 839–847.
15.
Malhotra, P. K., and Veletsos, A. S. (1995). “Seismic response of unanchored and partially anchored liquid-storage tanks,”TR-105809. Electric Power Res. Inst. (EPRI), Palo Alto, Calif.
16.
Manos, G. C., and Clough, R. W.(1985). “Tank damage during the May, 1983, Coalinga earthquake.”J. Earthquake Engrg. Struct. Dyn., 13(4), 449–466.
17.
Miles, R. W. (1977). “Practical design of earthquake-resistant steel reservoirs.”Proc., Tech. Councils on Lifeline Earthquake Engrg., Specialty Conf., ASCE, Reston, Va., 168–182.
18.
Skinner, R. I., Robinson, W. H., and McVerry, G. H. (1993). An introduction to seismic isolation. John Wiley & Sons Ltd., Chichester, England.
19.
Tajirian, F. E. (1993). “Seismic isolation of critical components and tanks.”Proc., ATC-17-1 Seminar on Seismic Isolation, Passive Energy Dissipation, and Active Control. San Francisco, Calif., Vol. 1, 233–244.
20.
Tyler, R. G.(1978). “A tenacious base-isolation system using round steel bars.”Bull. New Zealand Nat. Soc. Earthquake Engrg., 11(4), 273–281.
21.
Veletsos, A. S. (1984). “Seismic response and design of liquid storage tanks.”Guidelines for the seismic design of oil and gas pipeline systems. ASCE, Reston, Va., 255–370, 443–461.
22.
Veletsos, A. S., Shivakumar, P., Tang, Y., and Tang, H. T. (1990). “Seismic response of anchored steel tanks.”Proc., 3rd Symp. on Current Issues Related to Nuclear Power Plant Struct., Equip., and Piping, A. J. Gupta, ed., North Carolina State Univ., N.C., 2–15.
23.
Veletsos, A. S., and Tang, Y.(1990). “Soil-structure interaction effects for laterally excited liquid-storage tanks.”J. Earthquake Engrg. Struct. Dyn., 19(4), 473–496.
24.
Zayas, V. A., and Low, D. S. (1995). “Application of seismic isolation to industrial tanks.”Proc., Pressure Vessels and Piping Conf., ASME/JSME, Hawaii, Vol. 319, 273–286.
Information & Authors
Information
Published In
Copyright
Copyright © 1998 American Society of Civil Engineers.
History
Published online: Apr 1, 1998
Published in print: Apr 1998
Authors
Metrics & Citations
Metrics
Citations
Download citation
If you have the appropriate software installed, you can download article citation data to the citation manager of your choice. Simply select your manager software from the list below and click Download.