Inelastic Behavior of Steel Frames with Added Viscoelastic Dampers
Publication: Journal of Structural Engineering
Volume 122, Issue 10
Abstract
This paper presents the results of shaking table studies on the inelastic behavior of two identical 2/5-scale three-story steel structures, one with and the other without viscoelastic (VE) dampers. The VE dampers were designed to provide the test structure with 8% and 15% critical damping ratios, respectively, at an ambient temperature of 28°C. Test results show that the VE dampers were effective in reducing the overall response and ductility demand on the test structure under strong earthquake ground motions. The structure with dampers sustained much stronger earthquake ground motions and experienced less damage than did the structure without dampers. During the tests, the VE dampers experienced large shear strains far beyond their design value of 60% strain and the usual design limit such as 100% strain. Analytical results show that damping ratios of the viscoelastically damped structure can be accurately predicted by the modal strain energy method. The inelastic seismic response can also be well described by using bilinear elements for the structural members. Results from this study suggest that a viscoelastically damped structure with sufficiently large damping may remain elastic under strong earthquake ground motions.
Get full access to this article
View all available purchase options and get full access to this article.
References
1.
Aiken, I. D., and Kelly, J. M. (1990). “Earthquake simulator testing and analytical studies of two energy-absorbing systems for multistory structures.”Rep. No. UCB/EERC-90/03, Univ. of California at Berkeley, Berkeley, Calif.
2.
ATC 17-1, Proc., Sem. on Seismic Isolation, Passive Energy Dissipation, and Active Control, (1993). Appl. Technol. Council, Redwood City, Calif.
3.
Bergman, D. M., and Hanson, R. D.(1993). “Viscoelastic mechanical damping devices tested at real earthquake displacements.”Earthquake Spectra, 9(3), 389–417.
4.
Chang, K. C., Oh, S.-T., Soong, T. T., and Lai, M. L.(1992). “Effect of ambient temperature on viscoelastically damped structure.”J. Struct. Engrg., 118(7), 1955–1973.
5.
Chang, K. C., Soong, T. T., Lai, M. L., and Nielsen, E. J. (1993a). “Viscoelastic dampers as energy dissipation devices for structural applications.”Earthquake Spectrum, 3(3).
6.
Chang, K. C., Lai, M. L., Soong, T. T., Oh, S-T., Hao, D. S., and Yeh, Y. C. (1993b). “Seismic behavior and design guidelines for steel frame structures with added viscoelastic dampers.”Tech. Rep. NCEER-93-0009.
7.
Chang, K. C., Chen, S. J., Hsu, C. J., and Chou, F. P. (1994). “Inelastic behavior of A 2/5 scale three story frame with added viscoelastic damper.”Proc., 1st Int. Conf. on Struct. Control, Los Angeles, Calif.
8.
Chou, F. P. (1994). “Seismic behavior of steel frames with added viscoelastic dampers,” Master's thesis, Dept. of Constr. Engrg., Nat. Inst. of Technol. (in Chinese).
9.
Earthquake Spectra. (1993). Earthquake Engrg. Res. Inst., Oakland, Calif.
10.
Johnson, C. D., and Kienholz, D. A. (1982). “Finite element prediction of damping in structures with constrained viscoelastic layers.”AIAA J., 20(9).
11.
National Earthquake Hazard Reduction Program. (1988). “Recommended provisions for the development of new seismic regulations for new buildings.”Part I Provisions, Bldg. Seismic Safety Council.
12.
Tsai, K. C., and Li, J. W. (1994). “DRAIN2D+, a general purpose computer program for static and dynamic analyses of inelastic 2D structures, supplemented with a graphic processor VIEW2D, user's guide.”Rep. No. CEER/R83-03, Ctr. for Earthquake Engrg. Res., Nat. Taiwan Univ., Taipei, Taiwan.
13.
Uang, C. M., and Bertero, V. V.(1990). “Evaluation of seismic energy in structures.”Earthquake Engrg. and Struct. Dynamics, 19, 77–90.
14.
Uniform building code. (1994). International Conference of Building Officials, Whittler, Calif.
Information & Authors
Information
Published In
Copyright
Copyright © 1996 American Society of Civil Engineers.
History
Published online: Oct 1, 1996
Published in print: Oct 1996
Authors
Metrics & Citations
Metrics
Citations
Download citation
If you have the appropriate software installed, you can download article citation data to the citation manager of your choice. Simply select your manager software from the list below and click Download.