Full‐Scale Implementation of Active Control. II: Installation and Performance
Publication: Journal of Structural Engineering
Volume 119, Issue 6
Abstract
An active bracing system has been designed, fabricated, and installed in a full‐scale dedicated test structure in Tokyo, Japan, for structural‐response control under seismic loads. In 1991, Soong et al. presented the design of the system along with simulation studies for the design earthquake. Presented in this paper, which is the second part of the sequence, are: (1) The description of the constructed system; and (2) the observed performance of the system under two actual earthquakes and other artificial loadings. Installation details of the system in the building structure are presented along with the selections for fail‐safe shutdown operations in case of malfunctions. Also presented are the procedures for proper maintenance and self‐testing, which ensure continuous control with minimal resources. The observed performance under artificial loadings and actual ground motions is compared with the estimated analytical response.
Get full access to this article
View all available purchase options and get full access to this article.
References
1.
Aizawa, S., Hayamizu, Y., Higashino, M., Soga, Y., Yamamoto, M., and Haniuda, N. (1990). “Experimental study of dual axis active mass damper.” Proc., U.S. Nat. Workshop on Struct. Control Res., G. W. Housner, and S. F. Masri, eds., University of Southern California, Los Angeles, Calif., 68–72.
2.
Reinhorn, A. M., Soong, T. T., Lin, R. C., Wang, Y. P., Fukao, Y., Abe, H., and Nakai, M. (1989). “1:4 Scale model studies of active tendon system and active mass dampers for aseismic protection.” Rep. No. NCEER‐89‐0026, National Center for Earthquake Engineering Research, State University of New York, Buffalo, N.Y.
3.
Reinhorn, A. M., Soong, T. T., Lin, R. C., Riley, M. A., Wang, Y. P., Aizawa, S., and Higashino, M. (1992). “Active bracing system: A full scale implementation of active control.” Rep. No. NCEER‐92‐0020, National Center for Earthquake Engineering Research, State University of New York, Buffalo, N.Y.
4.
Soong, T. T., Reinhorn, A. M., Wang, Y. P., and Lin, R. C. (1991). “Full scale implementation of active control. Part I: Design and simulation.” J. Struct. Engrg., ASCE, 117(11), 3516–3536.
5.
Wang, Y. P., Reinhorn, A. M., and Soong, T. T. (1992). “Development of design spectra for actively controlled wall frame buildings.” J. Engrg. Mech., ASCE, 118(5), 1201–1220.
6.
Yang, J. N. (1982). “Control of tall buildings under earthquake excitations.” J. Engrg. Mech. Div., ASCE, 108(1), 50–68.
Information & Authors
Information
Published In
Copyright
Copyright © 1993 American Society of Civil Engineers.
History
Received: Jun 26, 1992
Published online: Jun 1, 1993
Published in print: Jun 1993
Authors
Metrics & Citations
Metrics
Citations
Download citation
If you have the appropriate software installed, you can download article citation data to the citation manager of your choice. Simply select your manager software from the list below and click Download.