Tied Concrete Columns under Axial Load and Flexure
Publication: Journal of Structural Engineering
Volume 116, Issue 10
Abstract
Fifteen 12‐in. (305 mm) square and 9‐ft (2.74 m) long reinforced concrete columns were tested under flexure to large inelastic deformations while simultaneously subjected to constant axial load. The main purpose of this research was to investigate the behavior of column sections confined by rectilinear ties. Major variables considered in this program included: (1) Distribution of longitudinal and lateral steel, including unsupported longitudinal bars and supplementary cross‐ties with 90° hooks; (2) level of axial load ( to ); (3) amount of lateral steel (0.8% to 1.6% of core volume), and (4) spacing of ties (2‐1/8 in. to 6‐13/16 in. [54–173 mm]). Test results indicate that a larger number of laterally supported longitudinal bars results in better performance of columns. Unsupported longitudinal bars and cross‐ties with 90° hooks confine concrete effectively only at small deformations and result in rapid deterioration of column behavior at a later stage, particularly under high axial load levels. The amount of lateral steel and the level of axial load have significant effects on the column behavior.
Get full access to this article
View all available purchase options and get full access to this article.
References
1.
“Building code requirements for reinforced concrete.” (1983). ACI 318‐83, Amer. Concr. Inst., Detroit, Mich.
2.
“Code for the design of concrete structures for buildings.” (1984). CAN3‐A23.3M84, Canadian Standards Assoc, Rexdale, Canada.
3.
“Code of practice for the design of concrete structures.” (1982). NZS 3101, Part I, Standards Assoc. of New Zealand, Wellington, New Zealand.
4.
Hanson, N. W., and Rabbat, B. G. (1984). “Test of ductile behavior of lightweight concrete columns for seismic design.” Proc. 8th World Conf. on Earthquake Engrg., 5, 545–552.
5.
Park, R., Priestley, M. J. N., and Gill, W. D. (1982). “Ductility of square confined concrete columns.” Journal of Struct. Div. Engrg., ASCE, 108(4), 929–950.
6.
Park, R., Zahn, F. A., and Falconer, T. J. (1984). “Strength and ductility of reinforced and prestressed concrete columns and piles under seismic loading.” Proc. 8th World Conf. on Earthquake Engrg., 5, 513–520.
7.
Paulay, T. (1986). “A critique of the special provisions for seismic design of the building code requirements for reinforced concrete (ACI 318‐83),” ACI J., 83(2), 274–283.
8.
Priestley, M. J. N., and Park, R. (1987). “Strength and ductility of concrete bridge columns under seismic loading.” ACI J., 84(1), 61–76.
9.
Recommended lateral force requirements and commentary. (1980). Seismology Committee, Structural Engineers Association of California (SEAOC), San Francisco.
10.
Sakai, K., and Sheikh, S. A., (1989). “What do we know about confinement in RC columns?” ACI Struct. J., 86 (2), 192–207.
11.
Saatcioglu, M., and Ozceb, G. (1989). “Response of reinforced concrete columns to simulated seismic loading.” ACI Struct. J., 86(1), 3–12.
12.
Sheikh, S. A. (1982). “A comparative study of confinement models.” ACI J., 79(4), 296–306.
13.
Sheikh, S. A., and Uzumeri, S. M. (1980). “Strength and ductility of tied concrete columns.” J. Struct. Div., ASCE, 106(5), 1079–1102.
14.
Sheikh, S. A., and Uzumeri, S. M. (1982). “Analytical model for concrete confinement in tied columns.” J. Struct. Engrg., ASCE, 108(12), 2703–2722.
15.
Sheikh, S. A., and Yeh, C. C. (1982). “Flexural behavior of confined concrete columns.” ACI J., 83(3), 389–404.
16.
Soesianawati, M. T. (1986). “Limited ductility design of reinforced concrete columns.” Res. Report No. 86‐10, Univ. of Canterbury, Christchurch, New Zealand.
17.
Standard specifications for design and construction of concrete structures (1986). Part 1 (Design), Japanese Soc. of Civ. Engrs., Tokyo, Japan.
18.
Vecchio, F. J., and Collins, M. P. (1986). “The modified compression field theory for reinforced concrete elements.” ACI J., 83(2), 219–231.
19.
Yeh, C. C., and Sheikh, S. A. (1988). “Behavior of confined concrete columns under axial load and flexure.” Research Report No. UHCE88‐2, Dept. of Civ. Engrg., Univ. of Houston, Houston, Tex.
Information & Authors
Information
Published In
Copyright
Copyright © 1990 ASCE.
History
Published online: Oct 1, 1990
Published in print: Oct 1990
Authors
Metrics & Citations
Metrics
Citations
Download citation
If you have the appropriate software installed, you can download article citation data to the citation manager of your choice. Simply select your manager software from the list below and click Download.