Abstract
This paper compares analytical predictions with a series of full‐scale seismic tests on a concentrically K‐braced six‐story steel structure. A computer program for the inelastic frame analysis is used to calculate the dynamic response of the test structure, in which the degrading hysteresis rule is applied to the postbuckling brace model. From a comparison of the analytical and experimental results, it is concluded that the overall and local behavior of the full‐scale test structure subjected to simulated earthquakes can be reasonably well represented by using the implemented model and analytical method. It should, however, be noted that the overall hysteresis behavior and the damage distribution of the K‐braced structure are very sensitive to the differences in the hysteresis characteristics of each bracing member. A simple analysis with a lumped mass shear‐type model is also conducted to compare the responses between this design‐level analysis and the experimental results.
Get full access to this article
View all available purchase options and get full access to this article.
References
1.
AIJ. (1970). Design standard for steel structures. Architectural Institute of Japan, Tokyo, Japan.
2.
AIJ. (1975). Recommendations for plastic design in steel structures. Architectural Institute of Japan, Tokyo, Japan (in Japanese).
3.
AIJ. (1985). Design recommendations for composite constructions. Architectural Institute of Japan, Tokyo, Japan (in Japanese).
4.
BRI Steel Group. (1985). “U.S.‐Japan cooperative earthquake research program—Full‐scale tests on a six‐story steel building—Phase I test results.” Proc., Sixth Joint Tech. Coordinating Committee Meeting, Kaanapali, Maui, Hawaii.
5.
Foutch, D. A., Goel, S. C., and Roder, C. W. (1987). “Seismic testing of full‐scale steel building—Part I.” J. Struct. Engrg., ASCE, 113(11), 2111–2129.
6.
Housing Bureau and Building Research Institute. (1981). Recommendations for structural calculation based on the Revised Enforcement Order, Building Standard Law. Ministry of Construction, The Building Center of Japan (in Japanese).
7.
Jain, A. K., Goel, S. C., and Hanson, R. D. (1978a). “Hysteresis behavior of bracing members and seismic response of braced frames with different proportions.” Report No. UMEE 78R3, University of Michigan, Ann Arbor, Mich.
8.
Jain, A. K., and Goel, S. C. (1978b). “Hysteresis models for steel members subjected to cyclic buckling or cyclic end moments and buckling (User's guide for DRAIN‐2D: EL9 and EL10).” Report No. UMEE 78R6, University of Michigan, Ann Arbor, Mich.
9.
Kanaan, A. E., and Powell, G. H. (1973). “General purpose computer program for inelastic dynamic response of plane structures.” Report No. UCB/EERC‐73/6, EERC, University of California, Berkeley, Calif.
10.
Kato, B., and Akiyama, H. (1977). “Restoring force characteristics of steel frames equipped with diagonal bracings.” Trans. Architectural Institute of Japan, 260, 99–108 (in Japanese).
11.
Kato, B., Aoki, H., and Tagawa, Y. (1984). “Seismic behavior of steel frames with composite girders.” Proc., Eighth World Conf. on Earthquake Engineering, VI, San Francisco, Calif., 177–184.
12.
Nakashima, M., and Kato, H. (1987). “Experimental error growth behavior and error growth control in on‐line computer test control method.” BRI Research Paper No. 123, Building Research Institute, Tsukuba, Japan.
13.
Okamoto, S., et al. (1983). “Techniques for large scale testing at BRI Large Scale Structure Test Laboratory.” BRI Research Paper No. 101, Building Research Institute, Tsukuba, Japan.
14.
Roeder, C. W., Foutch, D. A., and Goel, S. C. (1987). “Seismic testing of fullscale steel building—Part II.” J. Struct. Engrg., ASCE, 113(11), 2130–2145.
15.
Sato, T., and Nakamura, T. (1982). “Structural analysis of framed structures, Part I.” New Architectural Engineering System, 36, Shokoku‐sha Book Co., Tokyo, Japan (in Japanese).
16.
Yamanouchi, H., et al. (1984). “Experimental results on a K‐braced steel structure under seismic loading utilizing full‐scale six‐story test structure.” Proc., Structural Stability Research Council 1984 Annual Technical Session and Meeting, San Francisco, Calif., 269–280.
17.
Yamanouchi, H., et al. (1989a). “Seismic behavior of a full‐scale concentrically braced steel building structure.” J. Struct. Engrg., ASCE.
18.
Yamanouchi, H., et al. (1989b). “Summary of full‐scale tests on a six‐story steel building.” BRI Research Paper, Building Research Institute, Tsukuba, Japan (in press).