Decreasing Measuring Errors of a Thermal Groundwater Flowmeter
Publication: Journal of Irrigation and Drainage Engineering
Volume 132, Issue 3
Abstract
The probe of a commercial thermal groundwater flowmeter was evaluated in the laboratory to determine the causes of apparent inaccurate results from field experiments conducted under high groundwater velocities in a gravel and coarse sand soil. The test was performed with water velocities from 2.3 to 103 m/day. Errors as large as 40% arose in the magnitude and direction of velocities within the measuring range specified by the manufacturer. The poor cosine response of the thermal sensor axes was found to be a major source of errors, because the accuracy of the velocity vector depends strongly on the angular response of the thermal sensor axes. This was partially corrected with a set of coefficients determined from laboratory tests.
Get full access to this article
View all available purchase options and get full access to this article.
Acknowledgments
The writers are very grateful to the Istituto di Scienze Marine (CNR of Venice, Italy) for having provided them with the same KVGF Model 30 used in the field experiment near Venice.
References
Bernardi, A., et al. (1995). “Confronto de metodologie di misura dei flussi idrici sotterranei in terreni disciolti.” Atti dei 2° convegno nazionale sulla protezione e gestione delle acque sotterranee: Metodologie, tecnologie e obiettivi, Quaderni di Geologia Applicata, Pitagora Editrice, Bologna, Italia, 1.23–1.32 (in Italian).
Dazzi, R., et al. (1996). “Dinámica de las aguas subterráneas en terrenos sueltos: principales metodologías de medición y su comparación.” Memorias del 3er Congreso Latinoamericano de Hidrología Subterránea, Asociación Latinoamericana de Hidrología Subterránea para el Desarrollo (ALHSUD), San Luis Potosí, México, Tema 1, 37–51 (in Italian).
Guthrie, M. (1986). “Use of a geo flowmeter for the determination of ground water flow direction.” Ground Water Monit. Rev., 6(1), 81–86.
Kerfoot, W. B. (1982). “Comparison of 2D and 3D groundwater flowmeter probes in fully-penetrating monitoring wells.” Proc., 2nd National Symp. on Aquifer Restoration and Ground Water Monitoring, National Water Well Association, Columbus, Ohio, 264–268.
Kerfoot, W. B., and Skinner, S. M. (1980). “Direct groundwater flow measurement.” 5th National Groundwater Quality Symp., Las Vegas.
Melville, J. G., Molz, F. J., and Guven, O. (1985). “Laboratory investigation and analysis of a ground-water flowmeter.” Ground Water, 23(4), 486–495.
Sisodia, S., and Helweg, O. J. (1998). “Modeling the heat sense flowmeter.” J. Irrig. Drain. Eng., 124(3), 148–151.
Weller, R. A., and Davis, R. E. (1980). “A vector measuring current meter.” Deep-Sea Res., Part A, 27A, 565–582.
Wilson, J. T., et al. (2001). “An evaluation of borehole flowmeters used to measure horizontal ground-water flow in limestones of Indiana, Kentucky, and Tennessee, 1999.” Water-Resources Investigations Rep. No. 01-4139, U.S. Dept. of the Interior, U.S. Geological Service, and U.S. Army Environmental Center, Indianapolis.
Information & Authors
Information
Published In
Copyright
© 2006 ASCE.
History
Received: Nov 18, 2003
Accepted: Apr 20, 2005
Published online: Jun 1, 2006
Published in print: Jun 2006
Authors
Metrics & Citations
Metrics
Citations
Download citation
If you have the appropriate software installed, you can download article citation data to the citation manager of your choice. Simply select your manager software from the list below and click Download.