Abstract
The objective of this study is to review existing methods and propose alternative or additional devices for scour protection around bridge piers. Engineering methods used in dealing with pier‐scour problems include placing coarse riprap around the foundations. An inverted filter layer is normally placed beneath the riprap to overcome leaching problems. Practical difficulties in laying the filter according to specifications, especially in deep water, often cause failure of the riprap layer. The study examines the effect of using a slot in the pier, or a collar around it, as devices for controlling the depth of scour. Experiments conducted in clear‐water conditions show that the use of a slot alone (with a width equal to one‐fourth of the pier diameter) can reduce equilibrium scour depth by as much as 20%. A combination of slot and collar can further reduce the scour depth. These devices may be useful as additional or alternative devices for scour protection.
Get full access to this article
View all available purchase options and get full access to this article.
References
1.
Breusers, H. N. C., Nicollet, G., and Shen, H. W. (1977). “Local scour around cylindrical piers.” J. Hydr. Res., 15(3), 211–252.
2.
Chee, R. K. W. (1982). “Live‐bed scour at bridge sites.” Report No. 290, School of Engrg., Univ. of Auckland, Auckland, New Zealand.
3.
Chiew, Y. M. (1984). “Local scour at bridge piers.” Report No. 355, School of Engrg., Univ. of Auckland, Auckland, New Zealand.
4.
Chiew, Y. M., and Melville, B. W. (1987). “Local scour around bridge piers.” J. Hydr. Res., 25(1), 15–26.
5.
Dahlberg, R. (1983). “Observations of scour around offshore structures.” Can. Geotech J., 20(4), 617–628.
6.
Ettema, R. (1980). “Scour at bridge piers.” Report No. 216, School of Engrg., Univ. of Auckland, Auckland, New Zealand.
7.
Isbash, S. V. (1935). “Construction of dams and other structures by dumping stones into flowing water.” Trans. Res. Inst. Hydrot. Leningrad, 17, 12–66.
8.
Koloseus, H. J. (1984). “Scour due to improper filters.” J. Hydr. Engrg., ASCE, 110(10), 1315–1324.
9.
Melville, B. W. (1975). “Local scour at bridge sites.” Report No. 117, School of Engrg., Univ. of Auckland, Auckland, New Zealand.
10.
Neill, C. R., ed. (1973). Guide to bridge hydraulics. Roads and Transportation Association of Canada, University of Toronto Press, Toronto, Canada.
11.
Parola, A. C, Jr., and Jones, J. S. (1991). “Sizing riprap to protect bridge piers from scour.” Transport. Res. Rec. (1290), 276–280.
12.
Posey, C. J. (1974). “Tests of scour protection for bridge piers.” J. Hydr. Engrg., ASCE, 110(12), 1773–1783.
13.
Shen, H. W., Schneider, V. R., and Karaki, S. S. (1966). Mechanics of local scour. U.S. Dept. of Commerce, National Bureau of Standards, Institute for Applied Technology, Washington, D.C.
14.
Tanaka, S., and Yano, M. (1967). “Local scour around a circular cylinder.” Proc. 12th IAHR Congress, Int. Assoc. of Hydr. Res., Delft, the Netherlands. 3, 193–201.
15.
Terzaghi, K., and Peck, R. B. (1948). Soil mechanics in engineering practice. John Wiley & Sons, Inc., New York, N.Y.
16.
Thomas, Z. (1967). “An interesting hydraulic effect occurring at local scour.” Proc. 12th IAHR Congress, Int. Assoc. of Hydr. Res., Delft, the Netherlands. 3, 125–134.
17.
“Laboratory investigation of filters for Enid and Granada dams.” (1948). Tech. Memorandum No. 30245, Jan., U.S. Waterways Experiment Station, Vicksburg, Miss.
18.
Worman, A. (1989). “Riprap protection without filter layers.” J. Hydr. Engrg., ASCE, 115(12), 1615–1630.