Dynamic Load Simulator: Development of a Prototype
Publication: Journal of Engineering Mechanics
Volume 127, Issue 12
Abstract
This technical note describes prototype development of a next generation of structural testing facility referred to here as a dynamic load simulator (DLS). The DLS simulates dynamic loading environment such as wind, waves, or earthquake effects, utilizing an electric or hydraulic actuator system instead of conventional facilities such as a wind tunnel, wave tank, or shaking table. Similitude requirements or the system capacity often preclude testing of large-scale models utilizing these facilities. In conventional test facilities continuous space-time variations of aerodynamic and hydrodynamic pressure fields and inertial loads are introduced to model the effects of wind, waves, or earthquakes. On the other hand, DLS provides discrete point loads utilizing a single- or multiactuator system to produce global dynamic load characteristics by taking into account the overall spatiotemporal correlation. A suite of typical loading protocols that includes sinusoidal, random correlated Gaussian, and non-Gaussian variations are simulated and verified experimentally utilizing single and dual actuator systems.
Get full access to this article
View all available purchase options and get full access to this article.
References
1.
Cermak, J. E., et al. ( 1999). Review of the need for a large-scale test facility for research on the effects of extreme winds on structures, National Academy Press, Washington, D.C.
2.
Cook, N. J., Keevil, A. P., and Stobart, R. K. ( 1988). “BRERWULF—The big bad wolf.” J. Wind Engrg. and Ind. Aerodynamics, 29, 99–107.
3.
Dorf, R. C., and Bishop, R. H. ( 1988). Modern control systems, Addison-Wesley, Reading, Mass.
4.
dSPACE floating-point controller board user's guide. (1997). Paderborn, Germany.
5.
Gurley, K., and Kareem, A. ( 1998). “Simulation of correlated non-Gaussian pressure fields.” Meccanica, 33(3), 309–317.
6.
Kareem, A., Kabat, S., and Haan, F. L., Jr. (1997). “Dynamic wind load simulator.” Proc., 8th U.S. Nat. Conf. on Wind Engrg.
7.
Mahin, S. A., Shing, P. B., Thewalt, C. R., and Hanson, R. D. (1989). “Pseudodynamic test method—Current status and future directions.”J. Struct. Engrg., ASCE, 115(8), 2113–2128.
8.
Reardon, G. F. ( 1988). “Simulated wind loading on houses.” Proc., Int. Conf. Housing and Constr. in Age of Technol.
9.
Reinhold, T. A., and Kareem, A. ( 1996). “Next generation of wind test facilities: A feasibility study.” Proc., 2nd Int. Workshop of Struct. Control, Next Generation of Intelligent Struct.
10.
Takandashi, K., and Nakashima, M. (1987). “Japanese activities on on-line testing.”J. Engrg. Mech., ASCE, 113(7), 1014–1032.