Hyperbolic Cooling Towers with Bulge Imperfections
Publication: Journal of Engineering Mechanics
Volume 124, Issue 11
Abstract
Owing to the large expanse of cooling towers, it is not possible to maintain the exact shape of a tower during construction. Alterations in shape also occur due to secondary effects like shrinkage and cracking. These alterations cause the failure of some towers. This paper deals with the application of semiloof shell elements in the analysis of towers with bulge imperfections for both dead and wind loads. Four parameters, namely, (1) radial error amplitude, ζm, (2) vertical location of bulge, Zm, (3) vertical extent of bulge, h, and (4) angular extent of bulge, θm, have been identified as responsible in influencing the behavior of imperfect towers. Their influence has been studied in detail and most critical geometry of the tower has been arrived at. The behavior of a tower with most critical geometry has also been studied. Analysis suggests that the effect of bulge imperfections on stress resultants is localized, the development of hoop tension in the imperfection zone is of primary concern, and stress changes induced are greater if the imperfection is located closer to the base. Shorter wavelength of an imperfection is more severe since curvature error is significantly high for low wavelength. With increase in angular extent, the change in hoop force is maximum for axisymmetric imperfection. Critical hoop stresses develop around the 70° meridian, where high hoop tension and high meridional moments develop that can induce yielding of hoop reinforcement and consequent failure.
Get full access to this article
View all available purchase options and get full access to this article.
References
1.
Al-Dabbagh, A., and Gupta, A. K.(1979). “Meridional imperfections in cooling tower design.”J. Struct. Engrg., ASCE, 105(6), 1089–1102.
2.
Ashwell, D. S., and Gallagher, R. H. (1976). “Finite elements for thin shells and curved members.” John Wiley and Sons, London.
3.
Byun and Kapania, R. K.(1992). “Nonlinear transient response of hyperbolic shells using a reduction method.”J. Comp. and Struct., 44(12), 255–262.
4.
“Criteria for structural design of reinforced concrete natural draught cooling towers.” (1985). IS 11504, Bureau of Indian Standards, New Delhi, India.
5.
Croll, J. C. A., Kaleli, F., and Kemp, K. O.(1979a). “Meridionally imperfect cooling towers.”J. Engrg. Mech., ASCE, 105(5), 761–777.
6.
Croll, J. C. A., Kaleli, F., Kemp, K. O., and Munro, J.(1979b). “A simplified approach to the analysis of geometrically imperfect cooling tower shells.”Engrg. Struct., 1, 92–98.
7.
Ellinas, C. P., Croll, J. C. A., and Kemp, K. O.(1980). “Cooling towers with circumferential imperfections.”J. Struct. Div., ASCE, 106(12), 2405–2423.
8.
Fricker, A. J. (1988). “An assessment of the role of geometric imperfections in the collapse of Fiddler's Ferry cooling tower.”J. Wind Engrg. and Industrial Aerodynamics, Elsevier Science Publishers BV, Amsterdam, The Netherlands, 95–104.
9.
Godbole, P. N., Viladkar, M. N., Krishna, P., and Karisiddapa. (1995). “Analysis of hyperbolic cooling towers with geometric imperfections under wind loads.”Proc. IXth Int. Conf. Wind Engrg., New Age International Publishers Ltd., Wiley Eastern Ltd., New Delhi, India, 1537–1550.
10.
Han, K. J., and Tong, G. S.(1985). “Analysis of hyperbolic cooling towers with local imperfections.”Engrg. Struct., 7, 273–279.
11.
Imperial Chemical Industries Ltd. (1974). Rep. on the Com. of Inquiry into the Collapse of the Cooling Tower at Ardeer Nylon Works, Ayrshire on Thursday, 27th Sept., 1973., Petrochemicals Division, Millbank, U.K.
12.
Kapania, R. K., and Yang, T. Y.(1986). “Formulation of an imperfect quadrilateral doubly curved shell element for postbuckling analysis.”J. AIAA, 24(2), 310–311.
13.
Karisiddappa. (1994). “Finite element analysis of hyperbolic cooling towers under wind loads,” PhD thesis, Dept. of Civ. Engrg., University of Roorkee, Roorkee, India.
14.
Kemp, K. O., and Croll, J. C. A.(1976). “The role of geometric imperfections in the collapse of cooling towers.”Struct. Engr., London, 54, 33–37.
15.
Martin, R. A. F., and Oliviera, C. A. M.(1988a). “Semiloof shell, plate and beam elements—New computer versions. Part I: Elements formulation.”J. Engrg. Computations, 5, 15–25.
16.
Martin, R. A. F., and Oliviera, C. A. M.(1988b). “Semiloof shell, plate and beam elements—new computer versions. Part II: Elements programming.”J. Engrg. Computations, 5, 26–38.
17.
Soare, M. (1967). “Cooling tower with constructional imperfections.”Concrete, Nov., 369–379.
18.
“Specifications for water cooling towers.” (1975). BS 4485, Part 4, British Standards Institution, London.
19.
Viladkar, M. N., Godbole, P. N., and Tankha, A. (1996). “Analysis of cooling towers with bulge imperfections.”Proc. IVth Int. Symp. on Natural Draught Cooling Towers, A. A. Balkema, Rotterdam, The Netherlands, 233–240.
20.
Yang, T. Y., and Kapania, R. K.(1983). “Shell elements for cooling tower analysis.”J. Engrg. Mech. Div., ASCE, 109(5), 1270–1289.
Information & Authors
Information
Published In
Copyright
Copyright © 1998 American Society of Civil Engineers.
History
Published online: Nov 1, 1998
Published in print: Nov 1998
Authors
Metrics & Citations
Metrics
Citations
Download citation
If you have the appropriate software installed, you can download article citation data to the citation manager of your choice. Simply select your manager software from the list below and click Download.