Evaluation of Input Variables in Adaptive-Network-Based Fuzzy Inference System Modeling for an Anaerobic Wastewater Treatment Plant under Unsteady State
Publication: Journal of Environmental Engineering
Volume 133, Issue 7
Abstract
A conceptual neural-fuzzy model based on adaptive-network-based fuzzy inference system (ANFIS) was proposed to estimate effluent chemical oxygen demand (COD) of a full-scale anaerobic wastewater treatment plant for a sugar factory operating at unsteady state. The fitness of simulated results was improved by adding two new input variables into the model; phase vectors of operational period and effluent COD values of last five days (history). In modeling studies, individual contribution of each input variable to the resulting model was evaluated. The addition of phase vectors and history of five days into the input variable matrix in ANFIS modeling for anaerobic wastewater treatment was applied for the first time in literature to increase the prediction power of the model. By this way, the correlation coefficient between estimated and measured values of output variable (COD) could be increased to the value of 0.8940, which is considered a good fit.
Get full access to this article
View all available purchase options and get full access to this article.
Acknowledgments
The writers would like to express their gratitude to Turkish Sugar Factories Cooperation and Sugar Institute for the financial support and permission to use plant data in this study. This study has also been supported by the Project Management Unit of Akdeniz University, Turkey.
References
American Public Health Administration/American Water Works Association/Water Environment Federation (APHA/AWWA/WEF). (1995). Standard methods for the examination of water and wastewater, 19th Ed., APHA, Washington, D.C.
Babuska, R., and Verbruggen, H. (2003). “Neuro-fuzzy methods for nonlinear system identification.” Annu. Rev. Control, 27(1), 73–85.
Batstone, D. J., and Keller, J. (2003). “Industrial applications of the IWA anaerobic digestion model No. 1 (ADM1).” Water Sci. Technol., 47(12), 199–206.
Bernard, O., Hadj-Sadok, Z., Dochain, D., Genovesi, A., and Steyer, J. P. (2001a). “Dynamical model development and parameter identification for an anaerobic wastewater treatment process.” Biotechnol. Bioeng., 75(4), 424–438.
Bernard, O., Polit, M., Hadj-Sadok, Z., Pengov, M., Dochain, D., Estaben, M., and Labat, P. (2001b). “Advanced monitoring and control of anaerobic wastewater treatment plants: Software sensors and controllers for an anaerobic digester.” Water Sci. Technol., 43(7), 175–182.
Blumensaat, F., and Keller, J. (2005). “Modelling of two-stage anaerobic digestion using the IWA Anaerobic Digestion Model No.1 (ADM1).” Water Res., 39(1), 171–183.
Choi, D. J., and Park, H. (2001). “A hybrid artificial neural network as a software sensor for optimal control of a wastewater treatment process.” Water Res., 35(16), 3959–3967.
Emmanouilides, C., and Petrou, L. (1997). “Identification and control of anaerobic digesters using adaptive, on-line trained neural networks.” Comput. Chem. Eng., 21(1), 113–143.
Estaben, M., Polit, M., and Steyer, J. P. (1997). “Fuzzy control for an anaerobic digester.” Control Eng. Pract., 5(9), 1303–1310.
Guwy, A. J., Hawkes, F. R., Wilcox, S. J., and Hawkes, D. L. (1997). “Neural network and on-off control of bicarbonate alkalinity in a fluidized-bed anaerobic digester.” Water Res., 31(8), 2019–2025.
Jang, R. J. S. (1993). “ANFIS: Adaptive-network-based fuzzy inference system.” IEEE Trans. Syst. Man Cybern., 23(5), 665–685.
Jang, R. J. S., and Sun, C. T. (1993). “Functional equivalence between radial basis function networks and fuzzy inference system.” IEEE Trans. Neural Netw., 4(1), 156–159.
Jang, R. J. S., and Sun, C. T. (1995). “Neuro-fuzzy modeling and control.” Proc. IEEE, 83(3), 378–405.
Karama, A., Bernard, O., Genovesi, A., Dochain, D., Benhammou, A., and Steyer, J. P. (2001). “Hybrid modeling of anaerobic wastewater treatment processes.” Water Sci. Technol., 43(1), 43–50.
Kaya, M. D., Hasiloglu, A. S., Bayramoglu, M., Yesilyurt, H., and Ozok, A. F. (2003). “A new approach to estimate anthropometric measurements by adaptive neuro-fuzzy inference system.” Int. J. Ind. Ergonom., 32(2), 105–114.
Kiely, G., Tayfur, G., Dolan, C., and Tanji, K. (1997). “Physical and mathematical modelling of anaerobic digestion of organic wastes.” Water Res., 31(3), 534–540.
Lardon, L., Punal, A., and Steyer, J. P. (2004). “On-line diagnosis and uncertainty management using evidence theory—Experimental illustration to anaerobic digestion process.” J. Process Control, 14(7), 747–763.
Lumley, D. (2002). “On-line instrument confirmation: How can we check that our instruments are working?” Water Sci. Technol., 45(4–5), 469–476.
Maier, H. R., and Dandy, G. C. (2000). “Neural networks for the prediction and forecasting of water resources variables: A review of modeling issues and applications.” Environ. Modell. Software, 15(1), 101–124.
Moletta, R., Verrier, D., and Albagnac, G. (1986). “Dynamic modelling of anaerobic digestion.” Water Res., 20(4), 427–434.
Müller, A., Marsili-Libelli, S., Aivasidis, A., Lloyd, T., Kroner, S., and Wandrey, C. (1997). “Fuzzy control of disturbances in a wastewater treatment plant.” Water Res., 31(12), 3157–3167.
Murnleitner, E., Becker, T. M., and Delgado, A. (2002). “State detection and control of overloads in the anaerobic wastewater treatment using fuzzy logic.” Water Res., 36(1), 201–211.
Polit, M., Estaben, M., and Labat, P. (2002). “A fuzzy model for an anaerobic digester, comparison with experimental results.” Eng. Applic. Artif. Intell., 15(5), 385–390.
Premier, G. C., Dinsdale, R., Guwy, A. J., Hawkes, F. R., Hawkes, D. L., and Wicox, S. J. (1999). “A comparison of the ability of black box and neural network models of arx structure to represent a fluidized bed anaerobic digestion process.” Water Res., 33(4), 1027–1037.
Punal, A., Palazzotto, L., Bouvier, J. C., Conte, T., Steyer, J. P., and Delgenes, P. (2003). “Automatic control of VFA in anaerobic digestion using a fuzzy logic based approach.” Water Sci. Technol., 48(6), 103–110.
Ramsay, I. R., and Pullammanappallil, P. C. (2005). “Full-scale application of a dynamic model for high-rate anaerobic wastewater treatment systems.” J. Environ. Eng., 131(7), 1030–1036.
Sahoo, G. B., Ray, C., and Wade, H. F. (2005). “Pesticide prediction in ground water in North Carolina domestic wells using artificial neural networks.” Ecol. Modell., 183(1), 29–46.
Steyer, J. P., Bernard, O., and Batstone, D. (2005). “Lessons learnt from of ICA in anaerobic digestion process.” Proc., IWA Int. Conf. on Instrumentation Control and Automation (ICA 2005), IWAQ, Pusan, Korea, Vol. 1, 267–276.
Tay, J. H., and Zhang, X. (1999). “Neural fuzzy modeling of anaerobic biological wastewater treatment systems.” J. Environ. Eng., 125(12), 1149–1159.
Tay, J. H., and Zhang, X. (2000). “A fast predicting neural fuzzy model for high-rate anaerobic wastewater treatment systems.” Water Res., 34(11), 2849–2860.
Vanrolleghem, P. A. (2003). “Models in advanced wastewater treatment plant control.” Proc., Colloque Automatique et Agronomie, AutoAgro 2003, Montpellier INRA Centre, Montpellier, France, [PVR415].
Weiland, P., and Rozzi, A. (1991). “The startup, operation and monitoring of high rate anaerobic treatment systems: Discusser’s report.” Water Sci. Technol., 24(8), 257–277.
Zadeh, L. A. (1965). “Fuzzy sets.” Inf. Control., 8(3), 338–353.
Information & Authors
Information
Published In
Copyright
© 2007 ASCE.
History
Received: Feb 21, 2006
Accepted: Jan 8, 2007
Published online: Jul 1, 2007
Published in print: Jul 2007
Authors
Metrics & Citations
Metrics
Citations
Download citation
If you have the appropriate software installed, you can download article citation data to the citation manager of your choice. Simply select your manager software from the list below and click Download.