Comparison of Oxygen Transfer Parameters Determined from the Steady State Oxygen Uptake Rate and the Non-Steady-State Changing Power Level Methods
Publication: Journal of Environmental Engineering
Volume 131, Issue 5
Abstract
In this study, a laboratory scale Univ. of Cape Town enhanced biological phosphorus removal process was operated under controlled conditions at a solids retention time of 15 days. Results are presented for the process performance and oxygen transfer parameters determined by applying the steady state oxygen uptake rate (OUR) and the changing power level (CPL) techniques, as per ASCE standard guidelines. The testing periods were temporally separated to eliminate interference of the tests. During the application of the CPL method, the sludge volume index gradually increased and higher values of the oxygen transfer rate and alpha were measured, in comparison to the data from the steady state OUR method, under similar process performance. Furthermore, the mass transfer rate decreased as the CPL method of testing continued. In contrast, the oxygen transfer parameters remained uniform during the time when the OUR method was applied. The data indicated that the CPL method resulted in higher and variable oxygen transfer parameters, even though the process performance remained unchanged. Therefore, a more rigorous evaluation of the CPL method is recommended to clarify the validity of the test.
Get full access to this article
View all available purchase options and get full access to this article.
Acknowledgments
This work was financially supported by the Natural Sciences and Engineering Research Council (NSERC) of Canada. The writers also wish to acknowledge the excellent technical backup provided by the UBC Environmental Engineering Laboratory.
References
American Public Health Association, American Water Works Association, and Water Environment Federation (APHA/AWWA/WEF). (1992). Standard methods for the examination of water and wastewater, 18th Ed., APHA, Washington, D.C.
American Society of Civil Engineers (ASCE). (1992). “A Standard for the measurement of oxygen transfer in clean water.” Standards No. 88-000, New York.
American Society of Civil Engineers (ASCE). (1997). “Standard guidelines for in-process oxygen transfer testing.” Standards No. 96-018, New York.
Andreadakis, A. D. (1993). “Physical and chemical properties of activated sludge floc.” Water Res., 27(12), 1707–1714.
Asselin, C., Comeau, Y., and Ton-That, Q. A. (1998). Alpha correction factor for static aerators and fine bubble diffusers used in municipal facultative aerated lagoons.” Proc., IAWQ 19th Biennial International Conf., Wastewater Treatment Plants, Vol. III, Vancouver, Canada, 79–85.
Baburin, L. A., Shvinka, J. E., and Viesturs, U. E. (1981). “Equilibrium oxygen concentration in fermentation fluids.” Eur. J. Appl. Microbiol. Biotechnol. 13, 15–18.
Boyle, W. C., and Campbell, H. J., Jr. (1984). “Experiences with oxygen transfer testing of diffused air systems under process conditions.” Water Sci. Technol., 16, 91–106.
Boyle, W. C., Stenstrom, M. K., Campbell, H. J., Jr., and Brenner, R. C. (1989). “Oxygen transfer in clean and process water for draft tube aerators in total barrier oxidation ditches.” J. Water Pollut. Control Fed., 61(8), 1449–1463.
Chaignon, V., Lartiges, B. S., El Samrani, A., and Mustin, C. (2002). “Evolution of size distribution and transfer of mineral particles between flocs in activated sludges: an insight into floc exchange dynamics.” Water Res., 36, 676–684.
Chu, K. H., van Veldhuizen, H. M., and van Loosdrecht, M. C. M. (2003). Respirometric measurement of kinetic parameters: effect of activated sludge floc size.” Water Sci. Technol., 48(8), 61–68.
Clark, M. M., and Flora, J. R. V. (1991). “Floc restructuring in varied turbulent mixing.” J. Colloid Interface Sci., 147(2), 407–421.
Cornel, P., Wagner, M., and Krause, S. (2003). “Investigation of oxygen transfer rates in full scale membrane bioreactors.” Water Sci. Technol., 47(11), 313–319.
Cousin, C. P., and Ganczarczyk, J. J. (1999). “Effect of calcium ion concentration on the structure of activated sludge flocs.” Environ. Technol., 20, 1129–1138.
Currie, R. B., and Stenstrom, M. K. (1994). “Full scale field testing of aeration diffusers systems at Union Sanitary District.” Proc., 67th Annual WEF Conf. and Exposition, Chicago, Vol. 1, 117–128.
Duchene, Ph., Cotteux, E., and Capela, S. (2001). “Applying fine bubble aeration to small aeration tanks.” Water Sci. Technol., 44(2–3), 203–210.
Dudley, J. (1995). “Process testing of aerators in oxidation ditches.” Water Res., 29(9), 2217–2219.
Environmental Protection Agency (EPA). (1989a). “Design manual-fine pore aeration systems.” EPA/625/1-89/023, Washington, D.C.
Environmental Protection Agency (EPA). (1989b). “Summary report: Fine pore (fine bubble) aeration systems.” Rep. No. EPA-625-8-85-010, Washington, D.C.
Fisher, M. J. (1996). “The effect of anaerobic and anoxic selectors on oxygen transfer in wastewater - a pilot scale study.” MS thesis, Univ. of Wisconsin, Madison, Wis.
Fisher, M. J., and Boyle, W. C. (1999). “Effect of anaerobic and anoxic selectors on oxygen transfer in wastewater.” Water Environ. Res., 71(1), 84–93.
Groves, K. P., Daigger, G. T., Simkin, T. J., Redmon, D. T., and Ewing. L. (1992). Evaluation of oxygen transfer efficiency and alpha-factor on variety of diffused aeration systems.” Water Environ. Res., 64(5), 691–698.
Govoreanu, R., Nopens, I., De Clercq, B., Saveyn, H., Van Der Meeren, P., and Vanrolleghem, P. A. (2001). “Influence of experimental parameters in on-line determination of floc size distribution.” Proc., 12th Romanian International Conf. on Chemistry and Chemical Engineering, (CD-ROM), Bucharest.
Han, B., Akeprathumchai, S., Wickramasinghe, S. R., and Qian, X. (2003). “Flocculation of biological cells: experiment vs. theory.” AIChE J., 49(7), 1687–1701.
Hoa, P. T., Nair, L., and Visvanathan, C. (2003). The effect of nutrients on extracellular polymeric substance production and its influence on sludge properties.” Water SA, 29(4), 437–442.
Hwang, H. J., and Stenstrom, M. K. (1985). “Evaluation of fine-bubble alpha factors in near full-scale equipment.” J. Water Pollut. Control Fed., 57(12), 1142–1151.
Iranpour, R., Miller, D., Kharaghani, S., and Stenstrom, M. (2000). “Discussion on ‘Effect of anaerobic and anoxic selectors on oxygen transfer in wastewater’ by M. J. Fisher and W. C. Boyle,” Water Environ. Res., 72(4), 507–509.
Krause, S., Cornel, P., and Wagner, M. (2003). “Comparison of different oxygen transfer testing procedures in full-scale membrane reactors.” Water Sci. Technol., 47(12), 169–176.
Lee, A., Ma, J., and Stenstrom, M. K. (2000). “ASCE DO parameter estimation program (DO_PAR).” Dept. of Civil & Environmental Engineering, Univ. of California at Los Angeles http://www.fields.seas.ucla.edu/research/dopar (Dec.10, 2000).
Lewis, W. K., and Whitman, W. G., (1924). “Principles of gas absorption.” Ind. Eng. Chem., 16, 1215–1220.
Li, D., and Ganczarczyk, J. (1993). “Factors affecting dispersion of activated sludge flocs.” Water Environ. Res., 65(3), 258–263.
Libra, J. A., Schuchardt, A., Sahlmann, C., Handschag, J., Wiesmaaa, U., and Gnirss, R. (2002). “Comparison of the efficiency of large-scale ceramic and membrane aeration systems with the dynamic off-gas method.” Water Sci. Technol., 46(4–5), 317–324.
Liss, S. N., Liao, B. Q., Dropp, I. G., Allen, D. G., and Leppard, G. G. (2002). “Effects of solids retention time on floc structure.” Water Sci. Technol., 46(1–2), 431–438.
Mahendraker, V. (2003). “Development of a unified theory of oxygen transfer in activated sludge processes—the concept of net respiration rate flux.” PhD thesis, Univ. of British Columbia, Vancouver, Canada.
Mahendraker, V., Mavinic, D. S., and Hall, K. J. (2003). “Comparative evaluation of mass transfer of oxygen in three activated sludge processes operating under uniform conditions.” J. Environ. Eng. Sci., accepted.
Mahendraker, V., Mavinic, D. S., and Rabinowitz, B. (2002). “Impact of hydrogen peroxide oxygen transfer tests on the performance of the biological nutrient removal process.” Environ. Technol., 23, 149–162.
Mueller, J. A., and Boyle, W. C. (1988). “Oxygen transfer under process conditions.” J. Water Pollut. Control Fed., 60(3), 332–341.
Muller, J. A., Boyle, W. C., and Popel, H. J. (2002). Aeration: Principles and practice, Vol.11, Water Quality Management Library, CRC Press, Boca Raton, Fla.
Mueller, J. S., and Stensel, H. D. (1990). “Biological enhanced oxygen transfer in the activated sludge process.” Res. J. Water Pollut. Control Fed., 62(2), 193–203.
QuickChem. (1990). Methods manual for the QuickChem Automated Ion Analyzer, LACHAT Instruments, Milwaukee, Wis.
Randall, C. W., Barnard, J. L., and Stensel, H. D. (1992a). Design and retrofit of wastewater treatment plants for biological nutrient removal, Technomic Publications, Lancaster, U.K.
Randall, C. W., Brannan, K. P., McClintock, S. A., and Pattarkine, V. M. (1992b). “The case for anaerobic reduction of oxygen requirements in biological phosphorus removal systems.” Water Environ. Res., 64(6), 824–833.
Redmon, D. T., Boyle, W. C., and Ewing, L. (1983). Oxygen transfer efficiency measurements in mixed liquor using off-gas technique.” J. Water Pollut. Control Fed. 55(11), 1338–1347.
Rols, J. L., Condoret, J. S., Fonade, C., and Goma, G. (1990). “Mechanism of enhanced oxygen transfer in fermentation using emulsified oxygen-vectors.” Biotechnol. Bioeng., 35, 427–435.
Rols, J. L., Condoret, J. S., Fonade, C., and Goma, G. (1991). “Modeling of oxygen transfer in water through emulsified organic liquids.” Chem. Eng. Sci., 46(7), 1869–1873.
SPSS Inc. (1999). “SYSTAT® 9. SPSS Inc.” Chicago <http:/www.spss.com>
Stenstrom, M. K. (1989). Upgrading existing activated sludge treatment plants with fine pore aeration systems.” Presented at the IAWPRC Conf. on Upgrading of Wastewater Treatment Plants, Proc. Munich, West Germany, 226–232.
Stenstrom, M. K., and Boyle, W. C. (1998). “Aeration systems—responsibilities of manufacturer, designer, and owner.” J. Environ. Eng., 124(5), 397–398.
Tay, J. H., Liu, Q. S., and Liu, Y. (2001). “The effect of shear force on the formation, structure and metabolism of aerobic granules.” Appl. Microbiol. Biotechnol., 57, 227–233.
Information & Authors
Information
Published In
Copyright
© 2005 ASCE.
History
Received: Aug 26, 2003
Accepted: Sep 3, 2004
Published online: May 1, 2005
Published in print: May 2005
Authors
Metrics & Citations
Metrics
Citations
Download citation
If you have the appropriate software installed, you can download article citation data to the citation manager of your choice. Simply select your manager software from the list below and click Download.