Comparative Analysis of Chlorine Dioxide, Free Chlorine and Chloramines on Bacterial Water Quality in Model Distribution Systems
Publication: Journal of Environmental Engineering
Volume 130, Issue 11
Abstract
Drinking water utilities may be required to change disinfectant to improve water quality and meet more stringent disinfection regulations. This research was conducted to assess and compares chlorine dioxide to free chlorine and chloramines on bacterial water quality monitored within model distribution systems (i.e., annular reactors). Following colonization with nondisinfected water, annular reactors containing either polycarbonate or cast iron coupons were treated with free chlorine, chlorine dioxide or chloramines. Two disinfectant doses (low/high) were tested for each disinfectant. Under specific environmental conditions, bacterial inactivation varied as a function of the disinfectant type and dose, sample type (bulk water versus biofilm bacteria) and coupon material. The ranking by efficiency was as follows: chlorine dioxide chlorine chloramines. On preformed biofilms of , the continuous application of a disinfectant led to a log removal of heterotrophic bacteria concentrations for suspended and biofilm bacteria ranging from 1.1 to 4.0, and from 0.2 to 2.5, respectively. Doubling the amount of disinfectant doses led to an additional log inactivation of 1–2.5 of heterotrophic bacteria levels. This study demonstrates that bacterial inactivation in distribution systems is governed by various inter-related parameters. The data indicate that chlorine dioxide represents a viable alternative for secondary disinfection in distribution systems.
Get full access to this article
View all available purchase options and get full access to this article.
References
1.
American Public Health Association (American Water Works Association (Water Environmental Federation (APHA), AWWA), WEF). ( 1998). Standard methods for the examination of water and wastewater, 20th Ed., Washington, D.C.
2.
Baribeau, H., Prévost, M., Desjardins, R., Lafrance, P., and Gates, D. J. (2002). “Chlorite and chlorate ion variability in distribution systems.” J. Am. Water Works Assoc., 94(7), 96–105.
3.
Block, J.C. ( 1995). “Survival and growth of E. coli in drinking water distribution systems.” Proc., Int. Conf. on Coliforms and E. Coli, Leeds, U.K.
4.
Block, J. C., Haudidier, K., Paquin, J. L., Miazga, J., and Levi, Y. (1993). “Biofilm accumulation in drinking water distribution systems.” Biofouling, 6, 333–340.
5.
Butterfield, P. W., Camper, A. K., Ellis, B. D., and Jones, W. L. (2002). “Chlorination of model drinking water biofilm: implications for growth and organic carbon removal.” Water Res., 36(17), 4391–4406.
6.
Butterfield, P., Camper, A.K., Jones, W.L., and Ellis, B.D. ( 1999). “Effects of chlorine on biofilm growth and substrate uptake in model drinking water systems.” Proc., American Water Works Association Water Quality Technology Conf., Tampa, Fla.
7.
Calomiris, J.J., and Scocca, J.J. ( 1994). The cell surface and survival of biofilm bacteria in the chlorinated drinking water system. Proc., American Water Works Association Water Quality Technology Conf., San Francisco.
8.
Camper, A.K. ( 1995). “Factors influencing biofilm growth in drinking water distribution systems.” PhD thesis, Montana State Univ., Bozeman, Mont.
9.
Camper, A.K. ( 1996). Factors limiting microbial regrowth in distribution systems: Laboratory and pilot scale experiments, American Water Works Association Research Foundation, Denver.
10.
Camper, A.K. ( 1997). “Environmental effects on bacterial dynamics in drinking water biofilms.” Proc., American Water Works Association Water Quality Technology Conf., Denver.
11.
Camper, A.K., Goodrum, L., and Jones, W.L. ( 1997). “Comparison of free chlorine and monochloramine for controlling of biofilm.” Proc., American Water Works Association Water Quality Technology Conf., Denver.
12.
Clark, R. M., Lykins, B. W., Block, J. C., Wymer, L. J., and Reasoner, D. J. (1994). “Water quality changes in a simulated distribution system.” J. Water Supply Res. Technol. – Aqua, 43(6), 263–277.
13.
Clement, J., Camper, A.K., and Sandvig, A. ( 2002). “Influence of distribution system infrastructure on bacterial regrowth.” Proc., 2002 American Water Works Association Water Quality Technology Conf., Seattle.
14.
Dernat, M., Leburgue, A., Oliveira, D., Gauthierand, J.P., and Pouillot, M. ( 1995). “Chlorine dioxide: A European perspective.” Proc., 3rd Int. Symp. on Chlorine Dioxide, New Orleans.
15.
Eisnor, J. D., and Gagnon, G. A. (2003). “A framework for the implementation and design of pilot-scale distribution systems.” J. Water Supply Res. Technol. – AQUA52(7), 501–520.
16.
Faust, S.D., and Aly, O.M. ( 1999). Chemistry of water treatment, CRC–Lewis, Boca Raton, Fla.
17.
Gagnon, G. A., and Huck, P. M. (2001). “Removal of easily biodegradable organic compounds by drinking water biofilms: analysis of kinetics and mass transfer.” Water Res., 35(10), 2554–2564.
18.
Gagnon, G.A., Huck, P.M., Irwin, G.S., and Ollos, P.J. ( 1998). “Defining the relationships between BOM, chlorine residual and bacterial regrowth.” Proc., International Solid Waste Association/American Water Works Association Symp. on Protecting Water Quality in the Distribution System: What is the Role of Disinfectant Residuals, Philadelphia.
19.
Gagnon, G. A., and Slawson, R. M. (1999). “An efficient biofilm removal method for bacterial cells exposed to drinking water.” J. Microbiol. Methods, 34, 203–214.
20.
Gatel, D., Dernat, M., and A. Bazer-Bachi ( 1995). “Drinking water use of chlorine dioxide: a case study in France.” Proc., 3rd Int. Symp. on Chlorine Dioxide, New Orleans.
21.
Geldreich, E.E. ( 1996). Microbial quality of water supply in distribution systems, CRC, Boca Raton, Fla.
22.
Gordon, G. (2001). “Is all chlorine dioxide created equal?” J. Am. Water Works Assoc., 93(4), 163–174.
23.
Gordon, G., Slootmaekers, B., Tachiyashiki, S., and Wood, D. W. (1990). “Minimizing chlorite ion and chlorate ion in drinking water treated with chlorine dioxide.” J. Am. Water Works Assoc., 82(4), 160–165.
24.
Hoehn, R. C., Ellenberger, C. S., Gallagher, D. L., Wiseman, E. V., Benninger, R. W., and Rosenblatt, A. (2003) “ and by-product persistence in a drinking water system.” J. Am. Water Works Assoc., 95(4), 141–150.
25.
Hofmann, R., Andrews, R. C., and Ye, Q. (1998). “Comparison of spectrophotometric methods for measuring chlorine dioxide in drinking water.” Environ. Technol., 19, 761–773.
26.
Hofmann, R., Andrews, R. C., and Ye, Q. (1999). “Impact of Giardia inactivation requirements on ClO2 by-products.” Environ. Technol., 20, 147–158.
27.
Huang, C. T., Yu, F. P., McFetters, G. A., and Stewart, P. (1995). “Nonuniform special patterns of respiratory activity within biofilms during disinfection.” Appl. Environ. Microbiol., 61, 2252–2256.
28.
Huck, P. M., and Gagnon, G. A. (2003). “Understanding the distribution system as a bioreactor: a framework for managing HPC levels.” Int. J. Food Microbiol.,92(3), 347–353.
29.
Ingols, R. S., and Ridenour, G. M. (1948). “Chemical properties of chlorine dioxide.” J. Am. Water Works Assoc., 40, 1207–1215.
30.
Lafrance, P., Duschene, P., Arcouette, N., and M. Prévost ( 1992). “The use of : case study of Laval.” Proc., 2nd Int. Symp. on Chlorine Dioxide, Houston.
31.
LeChevallier, M. W. (1990). “Coliform regrowth in drinking water: a review.” J. Am. Water Works Assoc., 82(11), 74–86.
32.
LeChevallier, M.W., et al. ( 1998). Microbial impact of biological filtration, American Water Works Association Research Foundation, Denver.
33.
LeChevallier, M. W., Cawthon, C. D, and Lee, R. G. (1988). “Inactivation of biofilm bacteria.” Appl. Environ. Microbiol., 54, 2492–2499.
34.
LeChevallier, M. W., Lowry, C. D., and Lee, R. G. (1990). “Disinfecting biofilm in model distribution system.” J. Am. Water Works Assoc., 82(7), 87–99.
35.
LeChevallier, M. W., Lowry, C. D., Lee, R. G., and Gibbon, D. L. (1993). “Examining the relationship between iron corrosion and the disinfection of biofilm bacteria in a model distribution system.” J. Am. Water Works Assoc., 85(7), 111–123.
36.
LeChevallier, M. W., Shaw, N., and Smith, D. B. (1996). “Full-scale studies of factors related to coliform regrowth in drinking water.” Appl. Environ. Microbiol., 62, 2201–2211.
37.
LeChevallier, M. W., Shulz, W., and Lee, R. G. (1991). “Bacterial nutrients in drinking water.” Appl. Environ. Microbiol., 57, 857–862.
38.
Limoni, B., and Teltsch, B. (1985). “Chlorine dioxide disinfection of drinking water – an evaluation of a treatment plant.” Water Res., 19, 1489–1495.
39.
Masschelein, W.J. ( 1991). “Chlorine dioxide in chemical oxidation, technologies for the nineties.” Proc., 1st Int. Symp. Chlorine Dioxide, Nashville, Tenn.
40.
Mathieu, L., Paquin, J. L., Block, J. C., Randon, G., Maillard, J., and Reasoner, D. (1992). “Parameters governing bacterial growth in water distribution systems.” Sci. Eau., 5, 91–112.
41.
McGuire, M. J., Lieu, N. I., and Pearthree, M. S. (1999). “Using chlorite ion to control nitrification.” J. Am. Water Works Assoc., 91(10), 52–61.
42.
Norton, C. D., and LeChevallier, M. W. (1997). “Chloramination: its effect on distribution system water quality.” J. Am. Water Works Assoc., 89(7), 66–77.
43.
Ollos, P. J., Huck, P. M., and Slawson, R. M. (2003). “Factors affecting biofilm accumulation in model distribution systems.” J. Am. Water Works Assoc., 95(1), 87–97.
44.
Ontario Ministry of the Environment. (2001). Ontario drinking water standards. Regulation 459/00, Ont., Canada.
45.
A. Rompré, Prévost,M., Briselois, P., Lavoie, J., and Lafrance, P. ( 1997). “Comparison of disinfectant efficiencies and their impact on biofilm growth in a model distribution system.” Proc., American Water Works Association Water Quality Technology Conf., Denver.
46.
Rooks, J. J. (1977). “Haloforms in drinking water.” J. Am. Water Works Assoc., 68(3), 168–172.
47.
Servais, P., Laurent, P., and Randon, G. (1995). “Comparison of the bacterial dynamics in various French distribution systems.” J. Water Supply Res. Technol.–Aqua, 44(1), 11–17.
48.
Sharp, R. R., Camper, A. K., Crippen, J. J., Schneider, J. D., and Leggiero, S. (2001). “Evaluation of drinking water biostability using biofilm methods.” J. Environ. Eng., 127(5), 403–410.
49.
Simpson, G.D. ( 1995). “Biofilm: removal and prevention with chlorine dioxide.” Proc., 3rd Int. Symp. on Chlorine Dioxide, New Orleans.
50.
U.S. Environmental Protection Agency (USEPA). ( 1999). Alternate disinfectants and oxidants guidance manual. EPA 815-R99-014, Narragansett, R.I.
51.
Volk, C. J., Hofmann, R., Chauret, C., Gagnon, G. A., Ranger, G., and Andrews, R. C. (2002). “Implementation of chlorine dioxide disinfection: Effects of the treatment change on drinking water quality in a full-scale distribution system.” J. Environ. Eng. Sci., 1(5), 323–330.
52.
Volk, C., and LeChevallier, M. W. (1999). “Impact of the reduction of nutrient levels on bacterial water quality in distribution systems.” Appl. Environ. Microbiol., 65, 4957–4966.
53.
Werdehoff, K. S., and Singer, P. C. (1987). “Chlorine dioxide effects on THMFP, TOXFP and the formation of inorganic by-products.” J. Am. Water Works Assoc., 79(9), 107–113.
54.
White, G.C. ( 1999). Handbook of chlorination and alternative disinfectants, 4th Ed., Wiley Interscience, New York.
55.
Wilczak, A., Jacangelo, J., Marcinko, J. P., Odell, L. H., Kermeyer, G. J., and Wolfe, R. L. (1996). “Occurrence of nitrification in chloraminated distribution systems.” J. Am. Water Works Assoc., 89(7), 66–77.
Information & Authors
Information
Published In
Copyright
Copyright © 2004 ASCE.
History
Published online: Nov 1, 2004
Published in print: Nov 2004
Authors
Metrics & Citations
Metrics
Citations
Download citation
If you have the appropriate software installed, you can download article citation data to the citation manager of your choice. Simply select your manager software from the list below and click Download.