Multilevel Soil-Vapor Extraction Test for Heterogeneous Soil
Publication: Journal of Environmental Engineering
Volume 123, Issue 2
Abstract
The design, performance, and analysis of a field method for quantifying contaminant mass-extraction rates and air-phase permeability at discrete vertical locations of the vadose zone are presented. The test configuration consists of a multiscreen extraction well and multilevel observation probes located in soil layers adjacent to the extraction well. For each level tested an inflatable packer system is used to pneumatically isolate a single screen in the extraction well, and a vacuum is applied to induce air flow through the screen. Test data include contaminant concentration and flow characteristics at the extraction well, and transient or steady-state pressure drawdown data at observation probes located at variable radii from the extraction well. The test method is applicable to the design of soil-vapor extraction (SVE) and bioventing remediation systems in a variety of geologic settings, particularly stratified soils. Application of the test method at a gasoline-polluted site located in the Piedmont physiographic region is described. Contaminant mass-extraction rates, expressed in terms of volatile hydrocarbons, varied from 0.16 to 14 kg/d.
Get full access to this article
View all available purchase options and get full access to this article.
References
1.
Aelion, C. M.(1996). “Impact of aquifer sediment grain size on petroleum hydrocarbon distribution and biodegradation.”J. Contaminant Hydro., 22, 109–121.
2.
Aelion, C. M., Shaw, J. N.,Widdowson, M. A., and Reeves, H. W. (1996). “The use of simplified methods for monitoring petroleum-contaminated ground water and soil vapor.”J. Soil Contamination, 5(3), 225– 241.
3.
Baehr, A. L., and Hult, M. F.(1991). “Evaluation of unsaturated zone air permeability through pneumatic tests.”Water Resour. Res., 27(1), 2605–2617.
4.
Bouwer, H. (1978). Groundwater hydrology. McGraw-Hill Book Co., Inc., New York, N.Y.
5.
Edwards, K. B., and Jones, L. C.(1994). “Air permeability from pneumatic tests in oxidized till.”J. Envir. Engrg., ASCE, 120(4), 329–347.
6.
Haney, O. R. (1994). “Design, performance, and analysis of a multi-level air permeability test,” MS thesis, Virginia Polytechnic Inst. and State Univ., Blacksburg, Va.
7.
Johnson, T. F. (1972). “Paleoenvironmental analysis and structural petrogenesis of the Carolina Slate Belt near Columbia, South Carolina,” MS thesis, Univ. of South Carolina, Columbia, S.C.
8.
Johnson, P. C., Stanely, C. C., Kemblowski, M. W., Byers, D. L., and Colthart, J. D.(1990). “A practical approach to the design, operation, and monitoring of in situ soil-venting systems.”Ground Water Monitoring Rev., 10(2), 159–178.
9.
Johnson, P. C., and Ettinger, R. A.(1994). “Considerations for the design of in situ vapor extraction systems: radius of influence vs. zone of remediation.”Ground Water Monitoring and Remediation, 14(3), 123–128.
10.
Massmann, J. W.(1989). “Applying groundwater flow models in vapor extraction system design.”J. Envir. Engrg., ASCE, 115(1), 129–149.
11.
Massmann, J. W., and Madden, M.(1994). “Applying groundwater flow models in vapor extraction system design.”J. Envir. Engrg., ASCE, 120(4), 313–328.
12.
Vennard, J. K., and Street, R. L. (1982). Elementary fluid mechanics. John Wiley and Sons, Inc., New York, N.Y.
13.
Widdowson, M. A., Ray, R. P., and Reeves, H. W., and Aelion, C. M. (1995). “Integrated site characterization for soil vapor extraction design.”Proc., The Geoenvironment 2000, Y. B. Acar and D. E. Daniel, eds., Vol. 2, ASCE, New York, N.Y., 1291–1305.
Information & Authors
Information
Published In
Copyright
Copyright © 1997 American Society of Civil Engineers.
History
Published online: Feb 1, 1997
Published in print: Feb 1997
Authors
Metrics & Citations
Metrics
Citations
Download citation
If you have the appropriate software installed, you can download article citation data to the citation manager of your choice. Simply select your manager software from the list below and click Download.