Abstract

This is a preliminary investigation of a method for the timely monitoring of wastewater biochemical oxygen demand (BOD). Many ecological and economic pressures support the use of BOD measurement methods fast enough to prevent process upsets. Since the standard laboratory procedure takes five days, and previously used fast tests are unsatisfactory for various reasons, tests were made on the Nissin Electric BOD-2000 instrument, which uses a yeast-based biosensor to measure soluble BOD in 30 min. It has been used successfully in the pharmaceutical and food industries. An initial attempt was made to place the instrument in field service. This attempt was unsuccessful, so the present study concentrated on comparing its operation in the laboratory with the results of the standard five-day BOD test (BOD5) procedure. The two types of tests were compared for samples from Terminal Island Treatment Plant (TITP), Bureau of Sanitation of the city of Los Angeles, using various combinations of filter porosities and wastewater sources in an attempt to establish a measurement routine that would not suffer from clogging problems that plagued the field test. Under these conditions the results from the instrument are excellent, and we briefly discuss further work needed to bring it into field use. This test is believed to be the first effort to assess the capability of this technology in a wastewater application in the United States.

Get full access to this article

View all available purchase options and get full access to this article.

References

1.
Biox-1010 BOD analyzer user's manual. (1994). Cosa Instrument Corp., Norwood, N.J.
2.
Borman, S. (1987). “Biosensors: potentiometric and amperometric.”Analytical Chem., 59(18), 1091A–1098A.
3.
Elmtholt, D. J., Tayor, R. F., and Miseo, E. V.(1992). “Emerging chemical sensor technologies for use in online applications,”ISA Trans., 31(4), 67–73.
4.
Hale, P. D., Inagaki, T., Karan, H. I., Okamoto, Y., and Skatheim, T.(1989). “A new class of amperometric biosensor incorporating a polymeric electron-transfer mediator.”J. Am. Chemical Soc., 111(9), 3482–3484.
5.
Harita, K., Otani, Y., Hikuma, M., and Yasuda, T. (1985). “BOD quick estimating system utilizing a microbial electrode.”Proc., 4th IAWPRC Topical Workshop on Instrumentation and Control of Water and Wastewater Treatment and Transport Sys., R. A. R. Drake, ed., IAWPRC, 529–532.
6.
Hikuma, M., Suzuki, H., Yasuda, T., Karube, I., and Suzuki, S. (1979). “Amperometric estimation of BOD by using living immobilized yeasts.”Eur. J. Appl. Microbiol. and Biotechnol., (8), 289–297.
7.
Iranpour, R., Chacon, P., and Kac, M. (1988). Basic stochastic processes. Macmillan Publishng Co., New York, N.Y.
8.
Johnstone, B. (1985). “Japanese industry turns to biosensors.”New Scientist, (21), 36.
9.
Karube, I., Matsunaga, T., Mitsuda, S., and Suzuki, S. (1977). “Microbial electrode BOD sensors.”Biotechnol. and Bioengrg., (19), 1535–1547.
10.
Karube, I., Matsunaga, T., and Suzuki, S.(1977). “A new microbial electrode for BOD estimation.”J. Solid-Phase Biochem., 2(2), 97–105.
11.
Karube, I., Mitsuda, S., Matsunaga, T., and Suzuki, S.(1977). “A rapid method for estimation of BOD by using immobilized microbial cells.”J. Fermentation Technol., 55(3), 243–248.
12.
Kitagawa, Y.(1991). “Amperometric detection of alcohol in beer using flow cell and immobilized alcohol dehydrogenase.”Analytical Chem., 63(20), 2391–2393.
13.
LeBlanc, P. J.(1974). “Review of rapid BOD test methods.”J. Water Pollution Control Fed., 46(9), 2202–2207.
14.
MacKoul, D., Johnson, D. C., and Schick, K. G. (1984). “Effect of variation in flow rate on amperometric detection in flow injection analysis.”Analytical Chem., (56), 436–439.
15.
Matsumoto, K., Baeza Baeza, J. J., and Mottola, H. A.(1993). “Continuous-flow sensor strategy comprising a rotating bioreactor and a stationary ring amperometric detector.”Analytical Chem., 65(5), 636–639.
16.
Nissin BOD rapid measuring instruments: BOD-2000 and BOD-2200 instruction manual. (1994). Central Kagaku Corp. (CKC), Tokyo, Japan.
17.
Reigler, G. (1987). “3-minute BOD assessments.”InTech, 45–50.
18.
Schultz, J. S. (1991). “Biosensors.”Scientific Am., 64–69.
19.
Shamel, R. E., and Brown, S. A. (1992). “Biosensors: boon to bioprocessing.”Chemical Engrg. Progress, 63–64.
20.
Standard methods for the examination of water and wastewater, 18th ed. (1992). Am. Public Health Assn., Washington, D.C.
21.
Strand, S. E., and Carlson, D. A.(1984). “Rapid BOD measurement for municipal wastewater samples using a biofilm electrode.”J. Water Pollution Control Fed., 56(5), 464–467.
22.
Suzuki, H., Tamiya, E., and Karube, I.(1988). “Fabrication of an oxygen electrode using semiconductor technology.”Analytical Chem., 60(10), 1078–1080.
23.
Turner, A. P. F., Karude, L., and Wilson, G. S., (eds). (1987). Biosensors—fundamentals and applications. Oxford University Press, New York, N.Y., 357–359.
24.
Walt, D. R. (1992). “Recent advances in chemical sensors.”Chem. and Industry, 58–61.

Information & Authors

Information

Published In

Go to Journal of Environmental Engineering
Journal of Environmental Engineering
Volume 123Issue 2February 1997
Pages: 154 - 159

History

Published online: Feb 1, 1997
Published in print: Feb 1997

Permissions

Request permissions for this article.

Authors

Affiliations

Reza Iranpour
Res. Staff, Liquid Waste Mgmt. Div., Sanit., City of Los Angeles, P.O. Box 262, Culver City, CA 90230.
Bill Straub, Members, ASCE,
Res. Staff and Asst. Div. Mgr., Liquid Waste Mgmt. Div., Sanit., City of Los Angeles, N. 200 Main St., Los Angeles, CA 90012.
Tito Jugo
Res Staff, Liquid Waste Mgmt. Div., Sanit., City of Los Angeles, N. 200 Main St., Los Angeles, CA.

Metrics & Citations

Metrics

Citations

Download citation

If you have the appropriate software installed, you can download article citation data to the citation manager of your choice. Simply select your manager software from the list below and click Download.

Cited by

View Options

Get Access

Access content

Please select your options to get access

Log in/Register Log in via your institution (Shibboleth)
ASCE Members: Please log in to see member pricing

Purchase

Save for later Information on ASCE Library Cards
ASCE Library Cards let you download journal articles, proceedings papers, and available book chapters across the entire ASCE Library platform. ASCE Library Cards remain active for 24 months or until all downloads are used. Note: This content will be debited as one download at time of checkout.

Terms of Use: ASCE Library Cards are for individual, personal use only. Reselling, republishing, or forwarding the materials to libraries or reading rooms is prohibited.
ASCE Library Card (5 downloads)
$105.00
Add to cart
ASCE Library Card (20 downloads)
$280.00
Add to cart
Buy Single Article
$35.00
Add to cart

Get Access

Access content

Please select your options to get access

Log in/Register Log in via your institution (Shibboleth)
ASCE Members: Please log in to see member pricing

Purchase

Save for later Information on ASCE Library Cards
ASCE Library Cards let you download journal articles, proceedings papers, and available book chapters across the entire ASCE Library platform. ASCE Library Cards remain active for 24 months or until all downloads are used. Note: This content will be debited as one download at time of checkout.

Terms of Use: ASCE Library Cards are for individual, personal use only. Reselling, republishing, or forwarding the materials to libraries or reading rooms is prohibited.
ASCE Library Card (5 downloads)
$105.00
Add to cart
ASCE Library Card (20 downloads)
$280.00
Add to cart
Buy Single Article
$35.00
Add to cart

Media

Figures

Other

Tables

Share

Share

Copy the content Link

Share with email

Email a colleague

Share