Discussion of “Graph-Theoretic Surrogate Measure to Analyze Reliability of Water Distribution System Using Bayesian Belief Network–Based Data Fusion Technique” by Ngandu Balekelayi and Solomon Tesfamariam
This article is a reply.
VIEW THE ORIGINAL ARTICLEPublication: Journal of Water Resources Planning and Management
Volume 146, Issue 8
Get full access to this article
View all available purchase options and get full access to this article.
References
Bentley Systems. 2019. WaterGEMS. Exton, PA: Bentley Systems.
Blokker, M., E. Pieterse-Quirijns, E. Postmus, V. Meira Marmelo, and L. Lourenço Mendes. 2011. “Asset management of valves.” Water Asset Manage. Int. 7 (4): 12–15.
Creaco, E., M. Franchini, and S. Alvisi. 2010. “Optimal placement of isolation valves in water distribution systems based on vale cost and weighted average demand shortfall.” Water Resour. Manage. 24 (15): 4317–4338. https://doi.org/10.1007/s11269-010-9661-5.
Deb, A., J. Snyder, and W. Grayman. 2012. “Management of valves to improve performance reliability of distribution systems.” J. AWWA 104 (6): 87. https://doi.org/10.5942/jawwa.2012.104.0087.
Deb, A., J. Snyder, J. Hammel, S. McCammon, H. Jun, G. Loganathn, and W. Grayman. 2006. Criteria for valve location and system reliability,. Denver: Water Research Foundation.
Giustolisi, O. 2020. “Water distribution network reliability assessment and isolation valve system.” J. Water Resour. Plann. Manage. 146 (1): 04019064. https://doi.org/10.1061/(ASCE)WR.1943-5452.0001128.
Giustolisi, O., Z. Kapelan, and D. A. Savic. 2008. “An algorithm for automatic detection of topological changes in water distribution networks.” J. Hydraul. Eng. 134 (4): 435–446. https://doi.org/10.1061/(ASCE)0733-9429(2008)134:4(435).
Giustolisi, O., and D. Savic. 2010. “Identification of segments and optimal isolation valve system design in water distribution networks.” Urban Water 7 (1): 1–15. https://doi.org/10.1080/15730620903287530.
Juan, H., and G. V. Loganathan. 2007. “Valve-controlled segments in water distribution systems.” J. Water Resour. Plann. Manage. 133 (2): 145–155. https://doi.org/10.1061/(ASCE)0733-9496(2007)133:2(145).
Jun, H., G. V. Loganathan, A. Deb, and J. Snyder. 2007. “Valve distribution and impact analysis in water distribution systems.” J. Environ. Eng. 133 (8): 790. https://doi.org/10.1061/(ASCE)0733-9372(2007)133:8(790).
Kao, J., and P. Li. 2007. “A segment-based optimization model for water pipeline replacement.” J. AWWA 99 (7): 83–95. https://doi.org/10.1002/j.1551-8833.2007.tb07983.x.
Liberatore, S., and G. M. Sechi. 2009. “Location and calibration of valves in water distribution networks using a scatter-search meta-heuristic approach.” Water Resour. Manage. 24 (1): 139–156. https://doi.org/10.1007/s11269-008-9337-6.
Liu, H., T. Walski, G. Fu, and C. Zheng. 2017. “Failure impact analysis of isolation valves in a water distribution network.” J. Water Resour. Plann. Manage. 143 (7): 04017019. https://doi.org/10.1061/(ASCE)WR.1943-5452.0000766.
Meng, F., T. Walski, G. Fu, and D. Bulter. 2019 “The cost of being more resilient—A case study of valve maintenance in water distribution systems.” In Proc., EWRI Conf. Reston, VA: ASCE.
Moerman, A., M. Blokker, and R. Diemel. 2016. “Determining the size of isolation segments in drinking water distribution systems.” In Proc., 2016 CCWI Conf. Exeter, UK: Univ of Exeter.
Ozger, S., and L. W. Mays. 2004. “Chapter 7—Optimal location of isolation valves in water distribution systems: A reliability/optimization approach.” In Mays, L Water resource systems management tools. New York: McGraw-Hill.
Trietsch, E., and J. Vreeburg. 2005. “Reliability of valves and section isolation.” Water Sci. Technol. Water Supply 5 (2): 47–51. https://doi.org/10.2166/ws.2005.0021.
Walski, T. 1993. “Water distribution valve topology for reliability analysis: The reliability of water distribution systems.” Reliab. Eng. Syst. Saf. 42 (1): 21–27. https://doi.org/10.1016/0951-8320(93)90051-Y.
Walski, T. 2011. “How many isolation valves are needed in a water distribution system?” In Proc., Computers and Control in Water Industry Conf. Reston, VA: ASCE.
Walski, T., H. Liu, G. Fu, and C. Zhang. 2019 “Which isolation valves are most important.” In Proc., EWRI Conf. Pittsburgh: Environmental and Water Resources Institute.
Walski T., J. Weiler, and T. Culver. 2006. “Using criticality analysis to identify impact of valve location.” In Proc., 8th Annual Water Distribution Systems Analysis Symp., 27–30. Reston, VA: ASCE.
Information & Authors
Information
Published In
Copyright
©2020 American Society of Civil Engineers.
History
Received: Aug 8, 2019
Accepted: Jan 10, 2020
Published online: Jun 1, 2020
Published in print: Aug 1, 2020
Discussion open until: Nov 1, 2020
Authors
Metrics & Citations
Metrics
Citations
Download citation
If you have the appropriate software installed, you can download article citation data to the citation manager of your choice. Simply select your manager software from the list below and click Download.