Hydraulic Transients in Viscoelastic Branched Pipelines
This article has been corrected.
VIEW CORRECTIONThis article has a reply.
VIEW THE REPLYThis article has a reply.
VIEW THE REPLYPublication: Journal of Hydraulic Engineering
Volume 141, Issue 8
Abstract
Plastic pipes are widely used in pressurized water systems. Their viscoelastic behavior has to be taken into account in the design phase as well as in the interpretation of water-hammer signals for diagnostic purposes. The aim of the present paper is to experimentally investigate the transient waves’ transmission and reflection in branched networks of high density polyethylene (HDPE) pipes and to test the efficacy of a viscoelastic model for the interpretation of the results. Two laboratory Y-shaped systems were built in the Water Engineering Lab of the University of Cassino and Southern Lazio (Italy) and a set of water-hammer tests was conducted on them. A significant variation of transmission and reflection coefficients at the pipe junction is observed in comparison with the values suggested in classical textbooks. The strong agreement between the experimental pressure values and those obtained using the viscoelastic model suggests that the differences from the classical theory are due to the viscoelastic behavior of the material, since unsteady friction effects are negligible in the investigated scenarios.
Get full access to this article
View all available purchase options and get full access to this article.
References
Aklonis, J. J., MacKnight, W. J., and Shen, M. (1972). Introduction to polymer viscoelasticity, Wiley, New York.
Allievi, L. (1902). “Teoria generale del moto perturbato dell’acqua nei tubi in pressione (colpo d’ariete).” Annali della Società degli Ingegneri ed Architetti Italiani, 17(5), 285–325 (in Italian).
Almeida, A. B., and Koelle, E. (1992). Fluid transients in pipe networks, Computational Mechanics Publications, Elsevier Applied Science, Amsterdam, Netherlands.
Apollonio, C., Covas, D. I. C., de Marinis, G., Leopardi, A., and Ramos, H. M. (2014). “Creep functions for transients in HDPE pipes.” Urban Water J., 11(2), 160–166.
Bergant, A., Tijsseling, A. S., Vitkovsky, J. P., Covas, D. I. C., Simpson, A. R., and Lambert, M. F. (2008). “Parameters affecting water-hammer wave attenuation, shape and timing—Part 2: Case studies.” J. Hydraul. Res., 46(3), 382–391.
Brunone, B., and Ferrante, M. (2001). “Detecting leaks in pressurised pipes by means of transients.” J. Hydraul. Res., 39(5), 539–547.
Chaudhry, M. H. (1987). Applied hydraulic transients, 2nd Ed., Litton Educational, Van Nostrand, New York.
Covas, D. I. C., Stoianov, I., Mano, J., Ramos, H. M., Graham, N., and Maksimovic, C. (2004). “The dynamic effect of pipe-wall viscoelasticity in hydraulic transients. Part I—Experimental analysis and creep characterization.” J. Hydraul. Res., 42(5), 517–531.
Covas, D. I. C., Stoianov, I., Mano, J., Ramos, H. M., Graham, N., and Maksimovic, C. (2005). “The dynamic effect of pipe-wall viscoelasticity in hydraulic transients. Part II—Model development, calibration and verification.” J. Hydraul. Res., 43(1), 56–70.
Duan, H., Ghidaoui, M., Lee, P. J., and Tung, Y. (2010). “Unsteady friction and visco-elasticity in pipe fluid transients.” J. Hydraul. Res., 48(3), 354–362.
Ferrante, M., Massari, C., Brunone, B., and Meniconi, S. (2011). “Experimental evidence of hysteresis in the head discharge relationship for a leak in a polyethylene pipe.” J. Hydraul. Eng., 775–780.
Ferry, J. D. (1970). Viscoelastic properties of polymers, Wiley, New York.
Fox, J. A. (1989). Transient flow in pipes, open channels and sewers, Ellis Horwood Limited, Chichester, U.K.
Keramat, A., Tijsseling, A. S., Hou, Q., and Ahmadi, A. (2012). “Fluid-structure interaction with pipe-wall viscoelasticity during water hammer.” J. Fluid. Struct., 28, 434–455.
Lee, P. J., Duan, H. F., Ghidaoui, M., and Karney, B. (2014). “Frequency domain analysis of pipe fluid transient behavior.” J. Hydraul. Res., 51(6), 609–622.
Meniconi, S., Brunone, B., and Ferrante, M. (2012). “Water-hammer pressure waves interaction at cross section changes in series in viscoelastic pipes.” J. Fluid. Struct., 33, 44–58.
Pezzinga, G., Brunone, B., Cannizzaro, D., Ferrante, M., Meniconi, S., and Berni, A. (2014). “Two-dimensional features of viscoelastic models of pipe transients.” J. Hydraul. Eng., 04014036.
Soares, A. K., Covas, D. I. C., and Reis, R. L. F. (2008). “Analysis of PVC pipe-wall viscoelasticity during water hammer.” J. Hydraul. Eng., 1389–1394.
Streeter, V. L., and Wylie, E. B. (1978). Fluid transients, McGraw–Hill International Books, New York.
Wood, D. J., and Chao, S. P. (1971). “Effect of pipelines junctions on water hammer surges.” J. Transp. Eng., 97(3), 441–457.
Information & Authors
Information
Published In
Copyright
© 2015 American Society of Civil Engineers.
History
Received: Jul 28, 2014
Accepted: Mar 2, 2015
Published ahead of print: Apr 27, 2015
Published online: Apr 28, 2015
Published in print: Aug 1, 2015
Discussion open until: Sep 28, 2015
Authors
Metrics & Citations
Metrics
Citations
Download citation
If you have the appropriate software installed, you can download article citation data to the citation manager of your choice. Simply select your manager software from the list below and click Download.