The authors wish to correct errors in Fig. 4 and Eq. (4), both of which represent the distribution of β-coefficient values. Data derived from the Neely (1991) dataset are referenced as a function of the length of the pile, Lp, and are not representative of the midpoint of a soil layer of interest. The correct form of Eq. (4) is expressed in terms of Lp
β-coefficient=1.5forLp<6m
β-coefficient=[log(Lp275)1.5]4for6m<Lp<24m
(4)
β-coefficient=0.25forLp>24m
For this reason, β-coefficients derived from the new loading tests and the Federal Highway Administration (FHWA) design model are not immediately comparable to the Neely (1991) dataset, and are removed from the corrected Fig. 4 as presented here. [Similar corrections to Eq. (4) and Fig. 6 in Stuedlein and Gurtowski (2012) must be made.]
Fig. 4. Comparison of the proposed design model for the variation of β-coefficient with the length of the pile for augered cast-in-place piles in granular soils
It is important to note the distinction of the length variable with respect to reliability calculations. Reliability calculations for uplift originally were made with respect to the length of the pile for the new model, and are, therefore, consistent with the significant majority of the β-coefficient data, and with respect to the midpoint of the pile for the FHWA model, as is appropriate. Similarly, capacity calculations for piles in compression were made with respect to the length of the pile, as is appropriate and in accordance with the corrected Eq. (4).
Previously, the bias statistics associated with Eq. (4) as shown in Table 3 and plotted in the previous Fig. 8(b) were equal to 1.10 and 37% for the equivalent normal mean bias and its coefficient of variation (n=63). Fig. 8(b) has been revised to Fig. 8(a) with respect to the corrected Eq. (4) and Fig. 4, and compares the normal and lognormal distributions from Table 3 to the new sample bias distribution. Fig. 8(a) indicates that there is no impact to the previously determined continuous resistance bias distributions and, therefore, no impact to the resulting resistance factors for either compression or uplift. Thus, the corrections noted here do not affect any of the results, conclusions, or inferences in the paper.
Fig. 8. Cumulative distribution functions for resistance bias at the strength limit for augercast piles loaded in uplift using (a) Eq. (4) and n=51, considering the length of the pile; (b) FHWA model considering depth
However, it is anticipated that additions to the β-coefficient dataset resulting from newly reported data could result in changes to the resistance bias distributions, and such changes are both welcome and necessary to best represent possible uncertainty in the reliability-based strength limit design of augered cast-in-place piles.

References

Neely, W. J. (1991). “Bearing capacity of auger-cast piles in sand.” J. Geotech. Eng. Div., 117(2), 331–346.
Stuedlein, A. W., and Gurtowski, T. M. (2012). “Reliability of shaft resistance for augered cast-in-place piles in granular soils.” Full scale testing and foundation design: Honoring Bengt Fellenius, GSP No. 227, ASCE, Reston, VA.

Information & Authors

Information

Published In

Go to Journal of Geotechnical and Geoenvironmental Engineering
Journal of Geotechnical and Geoenvironmental Engineering
Volume 139Issue 11November 2013
Pages: 2005 - 2006

History

Received: Feb 18, 2013
Accepted: Mar 29, 2013
Published online: Oct 15, 2013
Published in print: Nov 1, 2013

Permissions

Request permissions for this article.

Authors

Affiliations

Armin W. Stuedlein, Ph.D., M.ASCE
P.E.
Assistant Professor, School of Civil and Construction Engineering, Oregon State Univ., 220 Owen Hall, Corvallis, OR 97331 (corresponding author). E-mail: [email protected]
William J. Neely, Ph.D., M.ASCE
P.E.
Chief Geotechnical Engineer, Western Region, Flatiron West, Inc., 1770 La Costa Meadows Dr., San Marcos, CA 92078. E-mail: [email protected]
Thomas M. Gurtowski, M.ASCE
P.E.
Vice President, Shannon & Wilson, Inc., P.O. Box 300303, Seattle, WA 98103. E-mail: [email protected]

Metrics & Citations

Metrics

Citations

Download citation

If you have the appropriate software installed, you can download article citation data to the citation manager of your choice. Simply select your manager software from the list below and click Download.

Cited by

View Options

Media

Figures

Other

Tables

Share

Share

Copy the content Link

Share with email

Email a colleague

Share