Retail-Grocery–Floor Failure
This article has a reply.
VIEW THE REPLYPublication: Journal of Performance of Constructed Facilities
Volume 9, Issue 2
Abstract
This paper describes a failure of linoleum-tile floor covering placed on a concrete slab in a retail grocery facility. Moisture caused the failure, but different parties involved in the project postulated different sources of the moisture, and consequently, each party proposed a different assignment of blame for the failure. This paper reviews moisture movement in concrete slabs and compares the different explanations for the failure. Relationships among the different parties and the impact of these relationships on their postulated causes for failure are also examined. The most likely source of the moisture that caused the tile failure was an excessively thick sand protective layer placed on the vapor retarder. One portion of the floor slab had been left uncompleted. This exposed the sand to prolonged rain, which resulted in a reservoir of water trapped between the floor slab and vapor retarder.
Get full access to this article
View all available purchase options and get full access to this article.
References
1.
American Concrete Institute. (1989). “Guide for concrete floor and slab construction.”Rep. 302.1R-89, Detroit, Mich.
2.
Bažant, Z. P., and Najjar, L. J. (1972). “Nonlinear water diffusion in nonsaturated concrete.”Materiaux et Constructions, 5(25), Paris, France, 3–20.
3.
Brewer, H. W.(1965). “Moisture migration-concrete slab-on-ground construction.”J. PCA Res. Development Lab., 7(2), 2–16.
4.
Carr, G. L., and Gunkel, R. C. (1984). “Laboratory studies of soil bedding requirements for flexible membrane liners.”Rep., EPA-600/2-84-021, Municipal Environmental Research Laboratory, U.S. Environmental Protection Agency, Cincinnati, Ohio.
5.
Day, R. W.(1992). “Moisture migration through concrete floor slabs.”J. Perf. of Constr. Fac., ASCE, 6(1), 46–51.
6.
Henry, R. L., and Kurtz, G. K. (1963). “Water vapor transmission of concrete and aggregates.”Tech. Rep. R 244, U.S. Naval Civil Engineering Laboratory, Port Hueneme, Calif.
7.
Huang, C. L. D., Siang, H. H., and Best, C. H. (1979). “Heat and moisture transfer in concrete slabs.”Int. J. Heat and Mass Transfer, London, England, Vol. 22, 257–265.
8.
Portland Cement Association. (1978). “Concrete floors on ground.”Rep. No. EB075.010, Skokie, Ill.
9.
Ross, S. S. (1984). Construction disasters, design failures, causes, and prevention . McGraw-Hill Book Co., New York, N.Y.
Information & Authors
Information
Published In
Copyright
Copyright © 1995 American Society of Civil Engineers.
History
Published online: May 1, 1995
Published in print: May 1995
Authors
Metrics & Citations
Metrics
Citations
Download citation
If you have the appropriate software installed, you can download article citation data to the citation manager of your choice. Simply select your manager software from the list below and click Download.