Abstract
As part of the (FEMA/SAC) Phase 2 program, this study focused on performance prediction and evaluation of existing steel SMRF buildings assumed to be built prior to the Northridge Earthquake. Several classes of buildings, which are representative of typical buildings based on year of construction and brittle pre-Northridge connections, were designed in accordance with the 1973, 1985, and 1994 UBC provisions. Then, the frame analysis models were developed including the effects of brittle connections, panel zone deformation, and interior gravity frames. Based on the drift demands and capacities calculated using each set of 20 SAC ground motions representing 2/50 and 50/50 hazard levels, a performance prediction and evaluation procedure based on the reliability framework is presented. Confidence levels that existing buildings will exceed the predefined performance level for different hazard levels are calculated. The pre-Northridge design and construction represented by the old building codes and brittle connections force the buildings to experience large seismic demand and result in a low confidence level in achieving the desired performance levels.
Get full access to this article
View all available purchase options and get full access to this article.
References
Applied Technology Council (ATC). (1995). “A critical review of current approaches to earthquake-resistant design.” Rep. No. ATC-34, Red Wood City, Calif.
Foutch, D. A. (2000). “State of art report on performance prediction and evaluation of moment-resisting steel frame structures.” SAC Rep. No. FEMA 355f, Federal Emergency Management Agency, Washington, D.C.
Hamburger, R. O., Foutch, D. A., and Cornell, C. A. (2000). “Performance basis of guidelines for evaluation, upgrade and design of moment-resisting steel frames.” Proc., 12th World Conf. in Earthquake Engineering, New Zealand Society for Earthquake Engineering, Upper Hutt, New Zealand, Paper Ref. No. 2543, 8 pages.
Jalayer, F., and Cornell, C. (1998). “Development of a probability-based demand and capacity factor design seismic format.” SAC Background Document, SAC Joint Venture, Richmond, Calif.
Krawinkler, H. (2000). “State of art report on systems performance of moment resisting steel frames subject to earthquake ground shaking.” SAC Rep. No. FEMA 355c, Federal Emergency Management Agency, Washington, D.C.
Lee, K., and Foutch, D. A. (2000). “Performance prediction and evaluation of special moment frame buildings for seismic loads.” SAC Background Rep. No. SAC/BD-00/25, SAC Joint Venture, Richmond, Calif.
Lee, K.-H., Stojadinovic, B., Goel, S. C., Margarin, A. G., Choi, J-H., Wongkaew, A., Reyher, B. P., and Lee, D.-Y. (1999). “Parametric tests on unreinforced connections.” SAC Rep. No. SAC/BD-00/01, SAC Joint Venture, Richmond, Calif.
Liu, J., and Astaneh-Asl, A. (2000). “Cyclic tests on simple connections including effects of the slab.” SAC Rep. No. SAC/BD-00/03, SAC Joint Venture, Richmond, Calif.
Luco, N., and Cornell, C. A. (1998). “Seismic drift demands for two SMRF structures with brittle connections” Proc., 6th U.S National Conf. on Earthquake Engineering Research Institute, Oakland., Calif., Paper Ref. No. T-158-3, 8 pages.
Prakash, V., Powell, G. H., and Campbell S. (1993). DRAIN-2DX, element description and user guide, University of California Press, Berkeley, Calif.
Roeder, C. W. (2000). “State of art report on connection performance.” SAC Rep. No. FEMA 355d, Federal Emergency Management Agency, Washington, D.C.
Schneider, S. P., and Amidi, A.(1998). “Seismic behavior of steel frames with deformable panel zones.” J. Struct. Eng., 124(1), 35–42.
Shi, S., and Foutch, D. A. (1997). “Connection element (type 10) for Drain-2DX.” Civil Eng. Rep., University of Illinois at Urbana-Champaign, Urbana, Il.
Somerville, P., Smith, N, Puntamurthula, S, and Sun, J. (1997). “Development of ground motion time histories for phase 2 of the FEMA/SAC steel project.” SAC Background Rep. No. SAC/BD-97/04, SAC Joint Venture, Richmond, Calif.
Uniform Building Code. (1973). International Conference Building Officials, Whittier, Calif.
Uniform Building Code. (1985). International Conference Building Officials, Whittier, Calif.
Uniform Building Code. (1994). International Conference Building Officials, Whittier, Calif.
Yun, S.-Y., and Foutch, D. A. (2000). “Performance prediction and evaluation of low and intermediate moment frame buildings for seismic loads.” SAC Background Rep. No. SAC/BD-00/26, SAC Joint Venture, Richmond, Calif.
Information & Authors
Information
Published In
Copyright
Copyright © 2002 American Society of Civil Engineers.
History
Received: Nov 7, 2000
Accepted: Apr 23, 2001
Published online: Apr 1, 2002
Published in print: Apr 2002
Authors
Metrics & Citations
Metrics
Citations
Download citation
If you have the appropriate software installed, you can download article citation data to the citation manager of your choice. Simply select your manager software from the list below and click Download.