Monitoring Design for Source Identification in Water Distribution Systems
Publication: Journal of Water Resources Planning and Management
Volume 136, Issue 6
Abstract
The design of sensor networks for monitoring contaminants in water distribution systems is currently an active area of research. Much of the effort has been directed at the contamination detection problem and the expression of public health protection objectives. Monitoring networks once they are in place, however, are likely to be used to gather monitoring data for source inversion as well. Thus, the design of these networks with the unique objectives associated with source inversion problems in mind is a necessity. Source inversion problems in water distribution systems are inherently underdetermined and exhibit solution nonuniqueness; and moreover, the structure of the errors associated with a solution are a function of monitoring observations. Optimal inverse experiment design is investigated as an approach for improving solution quality. The approach involves the selection of monitoring locations that are best suited to the generation of a well-conditioned source identification inverse problem. The monitoring design problem is formulated as a nonlinear combinatorial optimization problem and solved using a genetic algorithm. The monitoring designs generated exhibit an optimal substructure that may be exploited to develop more efficient methods of solution. An analysis is conducted to evaluate the source inversion performance of an optimized monitoring network relative to networks designed using different methods. The results of the analysis demonstrate that when the source identification problem is underdetermined, the number of monitoring sensors installed in the network is more important than the method used to locate them.
Get full access to this article
View all available purchase options and get full access to this article.
Acknowledgments
This work was partially funded under National Science Foundation Grant No. NSFBES-0238623. The writers would like to thank Dr. G. Mahinthakumar and his students for sharing the computational resources that made the analyses conducted possible. The content of this paper has undergone U.S. Environmental Protection Agency internal review. This, however, does not imply official endorsement of the views expressed herein.
References
Berry, J., Hart, W. E., Phillips, C. A., Uber, J. G., and Watson, J. -P. (2006). “Sensor placement in municipal water networks with temporal integer programming models.” J. Water Resour. Plann. Manage., 132(4), 218–224.
Berry, J. W., Fleischer, L., Hart, W. E., Phillips, C. A., and Watson, J. -P. (2005). “Sensor placement in municipal water networks.” J. Water Resour. Plann. Manage., 131(3), 237–243.
Boccelli, D. L., Tryby, M. E., Uber, J. G., Rossman, L. A., Zierolf, M. L., and Polycarpou, M. M. (1998). “Optimal scheduling of booster disinfection in water distribution systems.” J. Water Resour. Plann. Manage., 124(2), 99–111.
Cormen, T. H., Leiserson, C. E., Rivest, R. L., and Stein, C. (2001). Introduction to algorithms, 2nd Ed., MIT Press, Cambridge, Mass.
Cristo, C. D., and Leopardi, A. (2008). “Pollution source identification of accidental contamination in water distribution networks.” J. Water Resour. Plann. Manage., 134(2), 197–202.
Curtis, A. (1999). “Optimal experiment design: Cross-borehole tomographic examples.” J. Geophys. Eng., 136(3), 637–650.
Curtis, A., and Snieder, R. (1997). “Reconditioning inverse problems using the genetic algorithm and revised parameterization.” J. Geophys. Eng., 62(5), 1524–1532.
Goldberg, D. E. (1989). Genetic algorithms in search, optimization, and machine learning, Addison-Wesley, Reading, Mass.
Guan, J., Aral, M. M., Maslia, M. L., and Grayman, W. M. (2006). “Identification of contaminant sources in water distribution systems using simulation-optimization method: Case study.” J. Water Resour. Plann. Manage., 132(4), 252–262.
Harding, B. L., and Walski, T. M. (2000). “Long time-series simulation of water quality in distribution systems.” J. Water Resour. Plann. Manage., 126(4), 199–209.
Higham, N. J. (1992). “Estimating the matrix p-norm.” Numerische Mathematik, 62(1), 539–555.
Janke, R., Murray, R., Uber, J., and Taxon, T. (2006). “Comparison of physical sampling and real-time monitoring strategies for designing a contamination warning system in a drinking water distribution system.” J. Water Resour. Plann. Manage., 132(4), 310–313.
Krause, A., Leskovec, J., Guestrin, C., VanBriesen, J., and Faloutsos, C. (2008). “Efficient sensor placement optimization for securing large water distribution networks.” J. Water Resour. Plann. Manage., 134(6), 516–526.
Kumar, A., Kansal, M. L., and Arora, G. (1997). “Identification of monitoring stations in water distribution system.” J. Environ. Eng., 123(8), 746–752.
Laird, C. D., Biegler, L. T., and Van Bloemen Waanders, B. G. (2006). “Mixed-integer approach for obtaining unique solutions in source inversion of water networks.” J. Water Resour. Plann. Manage., 132(4), 242–251.
Laird, C. D., Biegler, L. T., Van Bloemen Waanders, B. G., and Bartlett, R. A. (2005). “Contaminant source determination for water networks.” J. Water Resour. Plann. Manage., 131(2), 125–134.
Lee, B. H., and Deininger, R. A. (1992). “Optimal locations of monitoring stations in water distribution systems.” J. Environ. Eng., 118(1), 4–16.
MathWorks. (2007). Matlab: Getting started guide, 10th Ed., The MathWorks, Inc., Natick, Mass.
McKay, M. D., Beckman, R. J., and Conover, W. J. (2000). “A comparison of three methods for selecting values of input variables in the analysis of output from a computer code.” Technometrics, 42(1), 55–61.
Ostfeld, A., et al. (2008). “The battle of the water sensor networks (BWSN): A design challenge for engineers and algorithms.” J. Water Resour. Plann. Manage., 134(6), 556–568.
Ostfeld, A., and Salomons, E. (2004). “Optimal layout of early warning detection stations for water distribution systems security.” J. Water Resour. Plann. Manage., 130(5), 377–385.
Ostfeld, A., and Salomons, E. (2005). “Securing water distribution systems using online contamination monitoring.” J. Water Resour. Plann. Manage., 131(5), 402–405.
Preis, A., and Ostfeld, A. (2006). “Contamination source identification in water systems: A hybrid model trees–linear programming scheme.” J. Water Resour. Plann. Manage., 132(4), 263–273.
Preis, A., and Ostfeld, A. (2008). “Multiobjective contaminant sensor network design for water distribution systems.” J. Water Resour. Plann. Manage., 134(4), 366–377.
Propato, M. (2006). “Contamination warning in water networks: General mixed-integer linear models for sensor location design.” J. Water Resour. Plann. Manage., 132(4), 225–233.
Propato, M., Cheung, P. B., and Piller, O. (2006). “Sensor location design for contaminant source identification in water distribution systems.” Proc., 8th Annual Water Distribution Systems Analysis Symp., ASCE, Reston, Va.
Propato, M., and Uber, J. G. (2004). “Linear least-squares formulation for operation of booster disinfection systems.” J. Water Resour. Plann. Manage., 130(1), 53–62.
Rossman, L. A. (2000). EPANET 2 users manual (EPA/600/R-00/057 ed.), Water Supply and Water Resources Div., National Risk Management Research Laboratory, U.S. EPA, Cincinnati.
Shang, F., Uber, J. G., and Polycarpou, M. M. (2002). “Particle backtracking algorithm for water distribution system analysis.” J. Environ. Eng., 128(5), 441–450.
Shastri, Y., and Diwekar, U. (2006). “Sensor placement in water networks: Stochastic programming approach.” J. Water Resour. Plann. Manage., 132(3), 192–203.
Tryby, M. E., Boccelli, D. L., Uber, J. G., and Rossman, L. A. (2002). “Facility location model for booster disinfection of water supply networks.” J. Water Resour. Plann. Manage., 128(5), 322–333.
Tryby, M. E., Mirghani, B. Y., Mahinthakumar, G. K., and Ranjithan, S. R. (2010). “A solution framework for environmental characterization problems.” Int. J. High Perform. Comput. Appl., 24(3), 265–283.
Wang, Z., Polycarpou, M., Uber, J., and Shang, F. (2006). “Adaptive control of water quality in water distribution networks.” IEEE Trans. Control Syst. Technol., 14(1), 149–156.
Zechman, E. M., Brill, E. D., Mahinthakumar, G., Ranjithan, S., and Uber, J. (2006). “Addressing non-uniqueness in a water distribution contaminant source identification problem.” Proc., 8th Annual Water Distribution Analysis Symp., S. G. Buchberger, ed., ASCE, Reston, Va., 126–126.
Zierolf, M., Polycarpou, M., and Uber, J. (1998). “Development and autocalibration of an input-output model of chlorine transport in drinking water distribution systems.” IEEE Trans. Control Syst. Technol., 6(4), 543–553.
Information & Authors
Information
Published In
Copyright
© 2010 ASCE.
History
Received: Mar 31, 2009
Accepted: Feb 15, 2010
Published online: Feb 17, 2010
Published in print: Nov 2010
Authors
Metrics & Citations
Metrics
Citations
Download citation
If you have the appropriate software installed, you can download article citation data to the citation manager of your choice. Simply select your manager software from the list below and click Download.