Seismic Upgrade of an Existing Tall Building Using Different Supplemental Energy Dissipation Devices
Publication: Journal of Structural Engineering
Volume 144, Issue 7
Abstract
The feasibility and cost-effectiveness of various retrofit techniques to improve the seismic performance of an existing 35-story steel building are examined. Three types of supplemental energy dissipation devices are used in conjunction with basic retrofit measures to achieve the collapse prevention performance objective of current standards. Devices considered include fluid viscous dampers (FVDs), viscous wall dampers, and buckling restrained braces. The placement of the devices was kept the same in all three cases, considering overall architectural, programmatic, and constructability issues. The mechanical characteristics of the devices were selected using a simplified approach to achieve the same overall effective damping ratios and story drifts consistent with the targeted collapse prevention performance objective. The results of nonlinear dynamic analyses indicate that the FVD scheme was the most efficient for this structure in achieving the targeted performance goal and provided the most cost-effective means of improving the structural behavior and reducing economic losses for Level 2 basic safety earthquake hazard events. Future research needs related to the use of supplemental energy dissipation devices in existing buildings are also discussed.
Get full access to this article
View all available purchase options and get full access to this article.
Acknowledgments
This paper was supported by the Pacific Earthquake Engineering Research Center (PEER) as part of its Tall Building Initiative and Next-Generation Attenuation Relationship programs. Special thanks are owed to Jiun-Wei Lai and Matthew Schoettler, who helped develop the OpenSees model for the as-built and Level 1 retrofit cases, as well as to Frank McKenna, Andreas Schellenberg, and Dimitrois Lignos, who provided numerous suggestions regarding the numerical models. The authors would also like to express their gratitude to Kazuhiko Kasai of the Tokyo Institute of Technology, Vesna Terzic of California State University, Long Beach, Joe Maffei and Lawrence Burkett of Maffei Structural Engineering, Amarnath Kasalanati of PEER, and Kit Miyamoto and Amir Gilani of Miyamoto International for sharing their valuable expertise in estimating the cost associated with retrofits and repairs.
References
AISC. 2010. Specification for structural steel buildings. ANSI/AISC 360. Chicago, IL: AISC.
AISC. 2016. Seismic provisions for structural steel buildings. ANSI/AISC 341. Chicago, IL: AISC.
Arima, F., M. Miyazaki, H. Tanaka, and Y. Yamazaki. 1988. “A study on buildings with large damping using viscous damping walls.” In Proc., 9th World Conf. on Earthquake Engineering, 821–826. Tokyo-Kyoto, Japan.
ASCE. 2010. Minimum design loads for buildings and other structures. ASCE/SEI 7. Reston, VA: ASCE.
ASCE. 2013. Seismic evaluation and retrofit of existing buildings. ASCE/SEI 41-13. Reston, VA: ASCE.
Baker, W. J., T. Lin, K. S. Shahi, and N. Jayaram. 2011. New ground motion selection procedures and selected motions for the PEER transportation research program. Berkeley, CA: Pacific Earthquake Engineering Research Center, Univ. of California.
Constantinou, M. C., and M. D. Symans. 1992. Experimental and analytical investigation of seismic response of structures with supplemental fluid viscous dampers. NCEER-92-0032. Buffalo, NY: National Center for Earthquake Engineering Research.
Duflot, P., and D. Taylor. 2008. “Experience and practical considerations in the design of viscous dampers.” In Proc., 3rd Int. Conf. on Footbridge. Porto, Portugal.
Dynamic Isolation Systems. 2011. “Brochures of viscous wall dampers: Superior earthquake protection for flexible buildings.” Accessed December 21, 2016. http://www.dis-inc.com/pdf_files/DIS_VWD.pdf.
FEMA. 2006. NEHRP recommended provisions: Design examples. FEMA 451. Washington, DC: FEMA.
FEMA. 2012. Seismic performance assessment of buildings, volume 1: Methodology. FEMA P-58. Washington, DC: FEMA.
Filippou, F., E. Popov, and V. Bertero. 1983. Effects of bond deterioration on hysteretic behavior of reinforced concrete joints. EERC 83-19. Berkeley, CA: Earthquake Engineering Research Center, Univ. of California.
Lai, J.-W., S. Wang, M. Schoettler, and S. Mahin. 2015. Seismic performance assessment of a tall building having Pre-Northridge moment-resisting connections. Berkeley, CA: Pacific Earthquake Engineering Research Center, Univ. of California.
Lee, D., and D. P. Taylor. 2001. “Viscous damper development and future trends.” J. Struct. Des. Tall Spec. Build. 10 (5): 311–320. https://doi.org/10.1002/tal.188.
Love, R., J. Newell, M. Sinclaire, and Y. Chen. 2012. “Performance-based design of an essential hospital with supplemental viscous damping in a high seismic zone.” In Proc., 15 World Conf. on Earthquake Engineering. Lisbon, Portugal.
Lu, X., Y. Zhou, and F. Yan. 2008. “Shaking table test and numerical analysis of RC frames with viscous wall dampers.” J. Struct. Eng. 134 (1): 64–76. https://doi.org/10.1061/(ASCE)0733-9445(2008)134:1(64).
Makris, N., and M. C. Constantinou. 1990. Viscous dampers: Testing, modelling and application in vibration and seismic isolation. Buffalo, NY: National Center for Earthquake Engineering Research, State Univ. of New York at Buffalo.
McKenna, F., M. Scott, and G. Fenves. 2010. “Nonlinear finite-element analysis software architecture using object composition.” J. Comput. Civ. Eng. 24 (1): 95–107. https://doi.org/10.1061/(ASCE)CP.1943-5487.0000002.
PACT (Performance Assessment Calculation Tool). 2012. “Version 2.9.9. FEMA.” Accessed December 16, 2016. http://www.fema.gov/media-library/assets/documents/90380.
PEER/ATC. 2010. Modeling and acceptance criteria for seismic design and analysis of tall buildings. PEER Rep. No. 2010/111. Berkeley, CA: Pacific Earthquake Engineering Research Center, Univ. of California.
Reinhorn, A. M., and C. Li. 1995. Experimental and analytical investigation of seismic retrofit of structures with supplemental damping, part III: Viscous damping walls. NCEER-95-0013. Buffalo, NY: National Center for Earthquake Engineering Research, State Univ. of New York at Buffalo.
Reinhorn, A. M., C. Li, and M. C. Constantinou. 1995. Experimental and analytical investigation of seismic retrofit of structures with supplemental damping, part I: Fluid viscous damping devices. NCEER-95-0001. Buffalo, NY: National Center for Earthquake Engineering Research, State Univ. of New York at Buffalo.
Rezaeian, S., Y. Bozorgnia, I. M. Idriss, K. W. Campbell, N. A. Abrahamson, and W. J. Silva. 2012. Spectral damping scale factors for shallow crustal earthquakes in active tectonic regions. Berkeley, CA: Pacific Earthquake Engineering Research Center, Univ. of California.
Shen, Z. 2015. “Major development of research and practices on seismic design of steel building structures in China.” In Proc., 8th Int. Conf. on Behavior of Steel Structures in Seismic Areas. Shanghai, China. China Architecture and Building Press.
Soong, T. T., and M. C. Constantinou. 1994. Passive and active structural vibration control in civil engineering. New York: Springer.
Uriz, P., and S. Mahin. 2008. Toward earthquake-resistant design of concentrically braced steel-frame structures. Berkeley, CA: Pacific Earthquake Engineering Research Center, Univ. of California.
Wang, S. 2017. “Enhance seismic resilience of high-rise buildings with optimal design of supplemental energy dissipation devices.” Ph.D. thesis, Univ. of California.
Wang, S., J.-W. Lai, M. Schoettler, and S. Mahin. 2017. “Seismic assessment of existing tall buildings: A case study of a 35-stoy steel building with Pre-Northridge connections.” Eng. Struct. 141 (Jun): 624–633. https://doi.org/10.1016/j.engstruct.2017.03.047.
Wang, S., and S. Mahin. 2017. “Seismic retrofit of a high-rise steel moment-resisting frame using fluid viscous dampers.” Struct. Des. Tall Spec. Build. 26 (10): e1367. https://doi.org/10.1002/ta.1367.
Yeung, N., and D. E. A. Pan. 1998. “The effectiveness of viscous-damping walls for controlling wind vibrations in multi-story buildings.” J. Wind Eng. Ind. Aerodyn. 77–78 (Sep): 337–348. https://doi.org/10.1016/S0167-6105(98)00154-8.
Information & Authors
Information
Published In
Copyright
©2018 American Society of Civil Engineers.
History
Received: May 31, 2017
Accepted: Jan 26, 2018
Published online: May 14, 2018
Published in print: Jul 1, 2018
Discussion open until: Oct 14, 2018
Authors
Metrics & Citations
Metrics
Citations
Download citation
If you have the appropriate software installed, you can download article citation data to the citation manager of your choice. Simply select your manager software from the list below and click Download.