Out-of-Plane Behavior of Slender Reinforced Masonry Shear Walls under In-Plane Loading: Experimental Investigation
Publication: Journal of Structural Engineering
Volume 144, Issue 3
Abstract
This paper presents the results of a multiphase research program aimed at investigating the out-of-plane stability of slender reinforced masonry shear walls (RMSWs) under in-plane reversed-cyclic loading. The objective of this study was to evaluate the adequacy of the out-of-plane stability provisions specified in the Canadian masonry design standard, which are currently in the form of height-to-thickness (h/t) limits. For the second phase of the program, which is presented in this paper, the evaluation was carried out by experimental testing of five slender full-scale RMSW specimens with varying h/t and height-to-length aspect ratios, reinforcement ratio, detailing, and applied axial precompression stress level. The tests were conducted by applying a displacement-controlled loading protocol at the top of each specimen, without restraining the in-plane rotational degree of freedom, until the lateral load-carrying capacity of the specimen was reduced to 60% of its peak capacity. Detailed qualitative and quantitative test results are summarized in this paper. In addition, a discussion regarding key factors found to affect the out-of-plane stability of RMSWs is presented. Preliminary findings suggest that the current Canadian masonry design standard h/t limits may be potentially conservative if used alone to assess the out-of-plane stability of RMSWs.
Get full access to this article
View all available purchase options and get full access to this article.
Acknowledgments
The project was generously sponsored by the Natural Sciences and Engineering Research Council of Canada (NSERC) through a Collaborative Research and Development Grant, the Canadian Concrete Masonry Producers Association, and the Masonry Institute of British Columbia. The first author acknowledges the support provided by the NSERC Industrial Postgraduate Scholarship program. Wall reinforcement was graciously donated by Harris Rebar Ltd. and Heritage Rebar Ltd. The invaluable assistance of the University of British Columbia and British Columbia Institute of Technology technicians and students was also critical to the project’s success.
References
Almeida, J. P., Rosso, A., Beyer, K., and Sritharan, S. (2014). “New experimental findings on the stability of thin reinforced concrete walls.” 5as Jornadas Portuguesa de Engenharia de Estructuras 2014—IX Congreso Nacional de Sismología e EngenhariaSísmica, Infoscience, Lausanne, Switzerland.
Azikimor, N. (2012). “Out-of-plane stability of reinforced masonry shear walls under seismic loading: In-plane reversed cyclic testing.” MASc thesis, Dept. of Civil Engineering, Faculty of Graduate Studies, Univ. of British Columbia, Vancouver, BC, Canada.
Azimikor, N., Brzev, S., Elwood, K. J., Anderson, D. L., and McEwen, W. (2017). “Out-of-plane instability of reinforced masonry uniaxial specimens under reversed cyclic axial loading.” Can. J. Civ. Eng., 44(5), 367–376.
Azimikor, N., Robazza, B. R., Elwood, K. J., Anderson, D. L., and Brzev, S. (2012). “An experimental study on the out-of-plane stability of reinforced masonry shear walls under in-plane reversed cyclic loads.” Proc., 15th World Conf. on Earthquake Engineering, Sociedade Portuguesa de Engenharia Sismica, Lisbon, Portugal.
Centeno, J. (2015). “Sliding displacements in reinforced masonry walls subjected to in-plane lateral loads.” Ph.D. thesis, Univ. of British Columbia, Vancouver, BC, Canada, 39–42.
Chai, Y. H., and Elayer, D. T. (1999). “Lateral stability of reinforced concrete columns under axial reversed cyclic tension and compression.” ACI Struct. J., 96, 780–789.
CNRC (National Research Council of Canada). (2015). “National building code of Canada.” Ottawa.
CSA (Canadian Standards Association). (2004a). “Billet-steel bars for concrete reinforcement.” CSA, G301.18-M92, Mississauga, ON, Canada.
CSA (Canadian Standards Association). (2004b). “CSA Mortar and grout for unit masonry.” CSA, A179-04, Mississauga, ON, Canada.
CSA (Canadian Standards Association). (2004c). “CSA Standards on concrete masonry units.” CSA A165-04, Mississauga, ON, Canada.
CSA (Canadian Standards Association). (2014). “Masonry design of buildings.” CSA S304-14, Mississauga, ON, Canada.
FEMA. (1999). “Evaluation of earthquake damaged concrete and masonry wall buildings: Basic procedures manual.” FEMA 306, Washington, DC.
Goodsir, W. J. (1985). “Design of coupled wall-frame structures for seismic action.” Ph.D. dissertation, Univ. of Canterbury, Christchurch, New Zealand, 248–256.
Hart, G. C., Kariotas, J., and Noland, J. L. (1988) “Masonry building performance survey.” Earthquake Spectra, 4(1), 181–196.
Joyal, M. P. (2012). “Enhanced ductility of masonry shear walls using laterally confined (self-reinforced) concrete block.” Ph.D. dissertation, McMaster Univ., Hamilton, ON, Canada.
NZCMA (New Zealand Concrete Masonry Association). (2004). “Design of reinforced concrete masonry structures.” NZS 4230:2004, Wellington, New Zealand.
Paulay, T., and Priestley, M. (1992). Seismic design of reinforced concrete and masonry buildings, Wiley, New York, 397–408.
Paulay, T., and Priestley, M. J. N. (1993). “Stability of ductile structural walls.” ACI Struct. J., 90, 385–392.
Priestley, N. J., and He, L. (1992). Seismic behaviour of flanged masonry shear walls, Univ. of California, San Diego, 97–112.
Robazza, B. R. (2013). “Out-of-plane stability of reinforced masonry shear walls under seismic loading: In-plane reversed cyclic testing.” MASc thesis, Univ. of British Columbia, Vancouver, BC, Canada.
Robazza, B. R., Brzev, S., Elwood, K. J., Anderson, D. L., and Yang, T. Y. (2015). “A study on the out-of-plane stability of ductile reinforced masonry shear walls subjected to in-plane reversed cyclic loading.” Proc., 12th North American Masonry Conf., Masonry Society Journal, Longmont, CO.
Robazza, B. R., Brzev, S., Yang, T. Y., Elwood, K. J., Anderson, D. L., and McEwen, B. (2016). “Effects of in-plane loading on the out-of-plane stability of slender reinforced concrete masonry shear walls.” Proc., 16th Int. Brick and Block Masonry Conf., CRC Press, London.
Robazza, B. R., Elwood, K. J., Anderson, D. L., and Brzev, S. (2013). “In-plane seismic behaviour of slender reinforced masonry shear walls: Experimental results.” Proc., 12th Canadian Masonry Symp., Vancouver, BC, Canada.
Shedid, M., Drysdale, R., and El-Dakhakhni, W. (2008). “Behavior of fully grouted reinforced concrete masonry shear walls failing in flexure: Experimental results.” J. Struct. Eng., 1754–1767.
Shedid, M., El-Dakhakhni, W., and Drysdale, R. (2010). “Alternative strategies to enhance the seismic performance of reinforced concrete-block shear wall systems.” J. Struct. Eng., 676–689.
TMS (The Masonry Society). (2016). “Building code requirements and specification for masonry structures.” TMS 602-16, Longmont, CO.
Vallenas, J. M., Bertero, V. V., and Popov, E. P. (1979). “Hysteretic behaviour of reinforced concrete structural walls.”, Univ. of California, Oakland, CA, 234.
Wallace, J. W. (2012). “Behaviour, design, and modeling of structural walls and coupling beams: Lessons from recent laboratory tests and earthquakes.” Int. J. Concr. Struct. Mater., 6(1), 3–18.
Information & Authors
Information
Published In
Copyright
©2018 American Society of Civil Engineers.
History
Received: Dec 7, 2015
Accepted: Aug 16, 2017
Published online: Jan 10, 2018
Published in print: Mar 1, 2018
Discussion open until: Jun 10, 2018
Authors
Metrics & Citations
Metrics
Citations
Download citation
If you have the appropriate software installed, you can download article citation data to the citation manager of your choice. Simply select your manager software from the list below and click Download.