Seismic Simulation of an Integrated Ceiling-Partition Wall-Piping System at E-Defense. I: Three-Dimensional Structural Response and Base Isolation
Publication: Journal of Structural Engineering
Volume 142, Issue 2
Abstract
The seismic response of a full-scale, 5-story steel moment frame building in base-isolated and fixed-base configurations with an integrated suspended ceiling-partition wall-sprinkler piping system that was shaken at E-Defense is critically assessed. Horizontal floor accelerations were constrained by the isolation systems to relatively low levels, which allowed observation of damage to the integrated system that was directly related to the vertical component of input acceleration. The floor slabs exhibited single mode vibration at their natural periods with widely varying effective damping. Peak vertical accelerations were amplified by an average factor ranging from 3 to 6 from the table to the middle of the floor slabs, at which amplification factors increased as slab vibration periods lengthened. Damage to the ceiling-partion-piping components initiated at slab accelerations of approximately 2 g and became extensive for slab accelerations exceeding 5 g. These metrics establish target vertical accelerations for achieving desired performance objectives.
Get full access to this article
View all available purchase options and get full access to this article.
Acknowledgments
This material is based upon work supported by the National Science Foundation under Grant Nos. CMMI-1113275 and CMMI-0721399 and the National Institute for Earth Science and Disaster Prevention (NIED) in Japan. Any opinions, findings, conclusions, or recommendations expressed in this document are those of the authors and do not necessarily reflect the views of the sponsors. The authors recognize and thank the following companies for providing product donations and technical support: Earthquake Protection Systems, Dynamic Isolation Systems, Aseismic Design Company, USG Building systems, Victaulic, Tolco, Hilti, Allan Automatic Sprinkler, and CEMCO Steel.
References
Al-Hussaini, T. M., Constantinou, M. C., and Zayas, V. A. (1994). “Seismic isolation of multi-story frame structures using spherical sliding isolation system.”, National Center for Earthquake Engineering Research, State Univ. of New York at Buffalo, Buffalo, NY.
Allen, D. E., and Pernica, G. (1998). “Control of floor vibration.”, National Research Council, Institute for Research in Construction, Ottawa.
ASTM. (2011). “Standard practice for installation of ceiling suspension systems for acoustical tile and lay-in panels in areas subject to earthquake ground motions.” ASTM E580/E580M-11ae1, West Conshohoken, PA.
Badillo-Almaraz, H., Whittaker, A., and Reinhorn, A. (2007). “Seismic fragility of suspended ceiling systems.” Earthquake Spectra, 23(1), 21–40.
Boice, M. D. (2003). “Study to improve the predicted response of floor systems due to walking.” M.S. thesis, Dept. of Civil Engineering, Virginia Polytechnic Institute and State Univ., Blacksburg, VA.
Bozorgnia, Y., and Campbell, K. W. (2004). “The vertical-to-horizontal response spectral ratio and tentative procedures for developing simplified V/H and vertical design spectra.” J. Earthquake Eng., 8(2), 175–207.
Bozorgnia, Y., Mahin, S. A., and Brady, A. G. (1998). “Vertical response of twelve structures recorded during the Northridge earthquake.” Earthquake Spectra, 14(3), 411–432.
Bradley, B. A., and Cubrinovski, M. (2011). “Near-source strong ground motions observed in the 22 February 2011 Christchurch earthquake.” Seismol. Res. Lett., 82(6), 853–865.
BSSC (Building Seismic Safety Council). (2009). “NEHRP recommended seismic provisions for new buildings and other structures.” FEMA P-750, Washington, DC.
Clark, P. W., Aiken, I. D., and Kelly, J. M. (1997). “Experimental studies of the ultimate behavior of seismically isolated structures.”, Earthquake Engineering Research Center, Univ. of California, Berkeley, CA.
Dao, N. D. (2012). “Seismic response of a full-scale steel frame building isolated with triple pendulum bearings under 3D excitation.” Ph.D. dissertation, Univ. of Nevada, Reno, NV.
FEMA. (2011). “Reducing the risks of nonstructural earthquake damage: A practical guide.” FEMA E-74, Washington, DC.
Fenz, D. M., and Constantinou, M. C. (2008). “Development, implementation, and verification of dynamic analysis models for multi-spherical sliding bearings.”, Multidisciplinary Center for Earthquake Engineering Research, State Univ. of New York at Buffalo, Buffalo, NY.
Furukawa, S., Sasaki, T., Sato, E., Okazaki, T., and Ryan, K. L. (2013a). “Comparison of vertical dynamic response characteristics of two base-isolated buildings based on full-scale shaking table test.” Proc., 13th World Conf. on Seismic Isolation, Energy Dissipation and Active Vibration Control of Structures, Japan Society for Seismic Isolation and Anti-Seismic Systems International Society, Sendai, Japan.
Furukawa, S., Sato, E., Shi, Y., Becker, T., and Nakashima, M. (2013b). “Full-scale shaking table test of a base-isolated medical facility subjected to vertical motions.” Earthquake Eng. Struct. Dyn., 42(13), 1931–1949.
Gavin, H. P., and Nigbor, R. L. (2012). “Performance of the base-isolated Christchurch Women’s Hospital in the Sep. 4, 2010 Darfield earthquake and the Feb. 22, 2011 Christchurch earthquake.” Proc., 20th Analysis and Computation Specialty Conf., ASCE Structures Congress, ASCE, Reston, VA.
Gilani, A. S. J., Reinhorn, A. M., Glasgow, B., Lavan, O., and Miyamoto, H. K. (2010). “Earthquake simulator testing and seismic evaluation of suspended ceilings.” J. Archit. Eng., 63–73.
Gilani, A. S. J., Takhirov, S., and Tedesco, L. (2013). “Seismic evaluation of suspended ceiling systems using static and dynamic procedures.” Proc., 44th Structures Congress, ASCE, Reston, VA.
Hicks, S. (2004). “Vibration characteristics of steel-concrete composite floor systems.” Prog. Struct. Eng. Mater., 6(1), 21–38.
ICC Evaluation Service. (2010). “AC 156: Acceptance criteria for seismic certification by shake table testing of nonstrucutral components.” Brea, CA.
Kasai, K., Mita, A., Kitamura, H., Matsuda, K., Morgan, T. A., and Taylor, A. W. (2013). “Performance of seismic protection technologies during the 2011 Tohoku-Oki earthquake.” Earthquake Spectra, 29(S1), S265–S293.
Kelly, J. M., Skinner, M. S., and Beucke, K. E. (1980). “Experimental testing of an energy absorbing seismic isolation system.”, Earthquake Engineering Research Center, Univ. of California, Berkeley, CA.
Lew, M., and Hudson, M. B. (1999). “The effects of vertical ground motion on base-isolated building systems.” Earthquake Spectra, 15(2), 371–375.
Mayes, R. L., Brown, A. G., and Pietra, D. (2012). “Using seismic isolation and energy dissipation to create earthquake-resilient buildings.” 2012 Annual Technical Conf., New Zealand Society for Earthquake Engineering, Wellington, New Zealand.
Miranda, E., and Aslani, H. (2003). “Building specific loss estimation for performance based design.” 2003 Pacific Conf. on Earthquake Engineering, New Zealand Society for Earthquake Engineering, Wellington, New Zealand.
Moroni, M. O., Sarrazin, M., and Soto, P. (2012). “Behavior of instrumented base-isolated structures during the 27 February 2010 Chile earthquake.” Earthquake Spectra, 28(S1), S407–S424.
Murray, T. M., Allen, D. E., and Ungar, E. E. (1997). “Floor vibrations due to human activity.”, American Institute of Steel Construction (AISC), Chicago.
NFPA (National Fire Protection Association). (2011). NFPA 13: Standard for the installation of sprinkler systems, 2010 Ed., Quincy, MA.
Retamales, R., Davies, R., Mosqueda, G., and Filiatrault, A. (2012). “Experimental seismic fragility of cold-formed steel framed gypsum partition walls.” J. Struct. Eng., 1285–1293.
Ryan, K., et al. (2013a). “Full scale 5-story building in fixed-base condition at E-Defense.” Network for Earthquake Engineering Simulation.
Ryan, K., et al. (2013b). “Full scale 5-story building with LRB/CLB isolation system at E-Defense.” Network for Earthquake Engineering Simulation.
Ryan, K., et al. (2013c). “Full scale 5-story building with triple pendulum bearings at E-Defense.” Network for Earthquake Engineering Simulation.
Ryan, K. L., Coria, C. B., and Dao, N. D. (2013d). “Large scale earthquake simulation of a hybrid lead rubber isolation system designed with consideration of nuclear seismicity.”, Center for Civil Engineering Research, Univ. of Nevada, Reno, NV.
Ryu, K. P., Reinhorn, A. M., and Filiatrault, A. (2012). “Full scale dynamic testing of large area suspended ceiling system.” Proc., 15th World Conf. on Earthquake Engineering, Portuguese Society for Earthquake Engineering, Lisbon, Portugal.
Saito, T. (2006). “Observed response of seismically isolated buildings.” Response control and seismic isolation of buildings, M. Higashino and S. Okamoto, eds., Taylor and Francis, New York.
Sato, E., Furukawa, S., Kakehi, A., and Nakashima, M. (2011). “Full-scale shaking table test for examination of safety and functionality of base-isolated medical facilities.” Earthquake Eng. Struct. Dyn., 40(13), 1435–1453.
Soroushian, S., et al. (2016a). “Seismic simulation of integrated ceiling-partition wall-piping system at E-Defense. II: Evaluation of nonstructural damage and fragilities.” J. Struct Eng., 04015131
Soroushian, S., Zaghi, A. E., Maragakis, E. M., Echevarria, A., Tian, Y., and Filiatrault, A. (2015b). “Analytical seismic fragility analyses of fire sprinkler piping systems with threaded joints.” Earthquake Spectra, 31(2), 1125–1155.
Staehlin, W. E., et al. (1996). “Miscellaneous building types.” Earthquake Spectra, 12(S1), 229–278.
Taylor, A. W., and Igusa, T. (2004). Primer on seismic isolation, ASCE, Reston, VA.
Tian, Y., Filiatrault, A., and Mosqueda, G. (2013). “Experimental seismic study of pressurized fire sprinkler piping subsystems.”, Multidisciplinary Center for Earthquake Engineering Research, State Univ. of New York at Buffalo, Buffalo, NY.
Wolff, E. D., and Constantinou, M. C. (2004). “Experimental study of seismic isolation systems with emphasis on secondary system response and verification of accuracy of dynamic response history analysis methods.”, Multidisciplinary Center for Earthquake Engineering Research, State Univ. of New York at Buffalo, Buffalo, NY.
Zaghi, A. E., Maragakis, E. M., Itani, A., and Goodwin, E. (2012). “Experimental and analytical studies of hospital piping subassemblies subjected to seismic loading.” Earthquake Spectra, 28(1), 367–384.
Information & Authors
Information
Published In
Copyright
© 2015 American Society of Civil Engineers.
History
Received: Dec 30, 2013
Accepted: Jul 2, 2015
Published online: Sep 11, 2015
Published in print: Feb 1, 2016
Discussion open until: Feb 11, 2016
Authors
Metrics & Citations
Metrics
Citations
Download citation
If you have the appropriate software installed, you can download article citation data to the citation manager of your choice. Simply select your manager software from the list below and click Download.