Two concrete-filled steel tube columns and four concrete-encased steel columns using high-strength steel (yield strength , 806, and 812 MPa) and high-strength concrete (compressive strength , 113, 104, and 184 MPa) were tested to investigate the effect of various sectional shapes and configurations on the eccentric axial load carrying capacity. This study focused on maximizing the contribution of the high-strength steel, preventing early crushing of the concrete (1) by using steel tubes or closely spaced ties for lateral confinement, (2) by using ultra high-strength (200 MPa) concrete with a high-crushing strain, and (3) by placing L-shaped steel sections at the corners of the cross section. The test results showed that the steel tube successfully restrained early concrete crushing and developed its full plastic stress; unlike expectation, early crushing occurred in the ultra high-strength concrete column; and the concrete-encased L-section column had higher peak strength and flexural stiffness than the conventional concrete-encased H-section columns. For the design of the concrete-filled columns, the conventional plastic design method is applicable, whereas the strain-compatibility method should be used for the design of the concrete-encased columns with limited lateral confinement.
Get full access to this article
View all available purchase options and get full access to this article.
Acknowledgments
This research was supported by grants from the High-Tech Urban Development Program (09 R&D A01) and R&D Policy Infra Program (Code 11-Technology Standardization-09-01), funded by the Ministry of Land, Transportation and Maritime Affairs of Korea, and the authors are grateful to the authorities for their support.
References
Akiyama, H., and Takahashi, M. (1990). “Influence of Bauschinger effect on seismic resistance of steel structures.” J. Struct. Constr. Eng., 418, 49–57 (in Japanese).
American Concrete Institute (ACI). (1997a). “Prediction of creep, shrinkage and temperature effects in concrete structures.”, Detroit.
American Concrete Institute (ACI). (1997b). “State-of-the-art report on high-strength concrete.”, Detroit.
American Concrete Institute (ACI). (2008). “Building code requirements for structural concrete and commentary.”, Farmington Hills, MI.
American Institute of Steel Construction. (2010). “Specification for structural steel buildings.”, Chicago.
American Institute of Steel Construction. (2010). “Seismic provisions for structural steel buildings.”, Chicago.
Architectural Institute of Japan (AIJ). (2001). Standard for structural calculation of steel reinforced concrete structures, 5th Ed., Tokyo.
ASTM. (2001). “Standard test method for compressive strength of cylindrical concrete specimens.” C39/C39M-01, West Conshohocken, PA.
ASTM (2009). “Standard test methods for tension testing of metallic materials.” E8/E8M-09, West Conshohocken, PA.
Bergmann, R., Puthli, R., and Fleischer, O. (2000). “Behavior of composite columns using high strength steel sections.” Proc., 4th Int. Conf. on Composite Construction in Steel and Concrete, ASCE, Reston, VA, 528–538.
Chung, K., Chung, J., and Choi, S. (2007). “Prediction of pre- and post-peak behavior of concrete-filled square steel tube columns under cyclic loads using fiber element method.” Thin-Walled Struct., 45(9), 747–758.
Collins, M. P., Mitchell, D., and MacGregor, J. G. (1993). ‘‘Structural design considerations for high-strength concrete.’’ Concr. Int., 15(5), 27–34.
Cusson, D., and Paultre, P. (1995). “Stress-strain model for confined high-strength concrete.” J. Struct. Eng., 468–477.
El-Tawil, S., and Deierlein, G. G. (1999). “Strength and ductility of concrete encased composite columns.” J. Struct. Eng., 1009–1019.
European Committee for Standardization (CEN). (2005). “Design of composite steel and concrete structures-part 1-1: General rules and rules for buildings.”, Brussels.
Fujimoto, T., Mukai, A., Nishiyama, I., and Sakino, K. (2004). “Behavior of eccentrically loaded concrete-filled steel tubular columns.” J. Struct. Eng., 203–212.
Inai, E., Mukai, A., Kai, M., Tokinoya, H., Fukumoto, T., and Mori, K. (2004). “Behavior of concrete-filled steel tube beam columns.” J. Struct. Eng., 189–202.
Kato, B. (1996). “Column curves of steel-concrete composite members.” J. Constr. Steel Res., 39(2), 121–135.
Kim, C. S., Park, H. G., Chung, K. S., and Choi, I. R. (2012). “Eccentric axial load testing for concrete-encased steel columns using 800MPa steel and 100MPa concrete.” J. Struct. Eng., 1019–1031.
Liu, D. (2004). “Behaviour of high strength rectangular concrete-filled steel hollow section columns under eccentric loading.” Thin-Walled Struct., 42(12), 1631–1644.
Liu, D. (2006). “Behaviour of eccentrically loaded high-strength rectangular concrete-filled steel tubular columns.” J. Constr. Steel Res., 62(8), 839–846.
Liu, D., and Gho, W. M. (2005). “Axial load behaviour of high-strength rectangular concrete-filled steel tubular stub columns.” Thin-Walled Struct., 43(8), 1131–1142.
Lue, D. M., Liu, J. L., and Yen, T. (2007). “Experimental study on rectangular CFT columns with high-strength concrete.” J. Constr. Steel Res., 63(1), 37–44.
Mirza, S. A., and Tikka, T. K. (1999). “Flexural stiffness of composite columns subjected to major axis bending.” ACI Struct. J., 96(1), 19–28.
Montuori, R., and Piluso, V. (2009). “Reinforced concrete columns strengthened with angles and battens subjected to eccentric load.” Eng. Struct., 31(2), 539–550.
Morino, S., Matsui, C., and Yoshikai, S. (1986). “Local buckling of steel elements in concrete encased columns.” Proc., Pacific Structural Steel Conf., Vol. 2, New Zealand Heavy Engineering Research Association, Auckland, New Zealand, 319–335.
Mursi, M., and Uy, B. (2004). “Strength of slender concrete filled high strength steel box columns.” J. Constr. Steel Res., 60(12), 1825–1848.
Nakahara, H., Sakino, K., and Inai, E. (1998). “Analytical model for compressive behavior of concrete filled square steel tubular columns.” Trans. Jpn. Concr. Inst., 20, 171–178.
Nakano, Y., Fujisawa, K., Nanba, T., Sakai, J., and Minami, K. (2006). “Experimental study on elastic-plastic behavior of SRC columns with high strength steel.” Mem. Fac. Eng., Fukuyama Univ., 30, 125–136 (in Japanese).
Oh, M. H., Ju, Y. K., Kim, M. H., and Kim, S. D. (2006). “Structural performance of steel-concrete composite column subjected to axial and flexural loading.” J. Asian Archit. Build. Eng., 5(1), 153–160.
Prickett, B. S., and Driver, R. G. (2006). “Behavior of partially encased composite columns made with high performance concrete.”, Dept. of Civil and Environmental Engineering, Univ. of Alberta, Edmonton, AB.
Ricles, J. M., and Paboojian, S. D. (1994). “Seismic performance of steel-encased composite columns.” J. Struct. Eng., 2474–2494.
Sakino, K., Nakahara, H., Morino, S., and Nishiyama, I. (2004). “Behavior of centrally loaded concrete-filled steel-tube short columns.” J. Struct. Eng., 180–188.
Shah, S. P., and Weiss, W. J. (1998). “Ultra high strength concrete: A look to the future.” Zia Symp. during ACI Spring Convention, Houston, Texas.
Uy, B. (2001). “Strength of short concrete filled high strength steel box columns.” J. Constr. Steel Res., 57(2), 113–134.
Varma, A. H., Ricles, J. M., Sause, R., and Lu, L. W. (2002). “Experimental behavior of high strength square concrete-filled steel tube columns.” J. Struct. Eng., 309–318.
Varma, A. H., Ricles, J. M., Sause, R., and Lu, L. W. (2004). “Seismic behavior and design of high strength square concrete-filled steel tube beam-columns.” J. Struct. Eng., 159–169.
Yamada, S., Imaeda, T., and Okada, K. (2002). “Simple hysteresis model of structural steel considering the Bauschinger effect.” J. Struct. Constr. Eng., 559, 225–232 (in Japanese).
Zubydan, A. H., and ElSabbagh, A. I. (2011). “Monotonic and cyclic behavior of concrete-filled steel-tube beam-columns considering local buckling effect.” Thin-Walled Struct., 49(4), 465–481.
Information & Authors
Information
Published In
Copyright
© 2013 American Society of Civil Engineers.
History
Received: Jul 19, 2012
Accepted: May 22, 2013
Published online: May 24, 2013
Published in print: Apr 1, 2014
Discussion open until: Apr 29, 2014
Authors
Metrics & Citations
Metrics
Citations
Download citation
If you have the appropriate software installed, you can download article citation data to the citation manager of your choice. Simply select your manager software from the list below and click Download.