Performance of Log Shear Walls Subjected to Monotonic and Reverse-Cyclic Loading
Publication: Journal of Structural Engineering
Volume 136, Issue 1
Abstract
Low-rise buildings are typically designed with shear walls and horizontal diaphragms to resist lateral load during windstorms and earthquakes. Although seismic performance and lateral load resistance behavior are generally well-understood for light-frame wood construction, this is not true for log construction. Research is needed to characterize log shear wall behavior subject to racking loads, and to develop recommendations for designing log walls to resist lateral loads from seismic or wind events. Monotonic and reverse-cyclic tests were conducted on log shear walls with 1:1, 2:1, and 4:1 aspect ratios. These walls showed higher resistance than conventional light-frame shear walls and similar hysteretic behavior to concrete and masonry shear walls. Log walls withstood large in-plane displacements without significant load reduction using lateral bracing typical of that used for light-frame wall testing; however, the test procedure would be improved by providing full-wall support to resist out-of-plane displacements of log shear walls. Design recommendations were developed based on the experiments reported herein.
Get full access to this article
View all available purchase options and get full access to this article.
Acknowledgments
This research was supported by a grant from the USDA CSREES. Log donations from Edgewood Log Structures are gratefully acknowledged.
References
American Forest and Paper Association, Inc. (AF&PA). 2005. National design specification for wood construction ASD/LRFD, AF&PA, Washington, D.C.
American Plywood Association (APA). (2000). Design/construction guide, APA—The Engineered Wood Association, Tacoma, Wash.
Applied Technology Council (ATC). (2007). “Quantification of building system performance and response parameters.” Rep. No. ATC-63, ⟨http://www.atcouncil.org/atc63.shtml⟩ (Feb. 5, 2007).
ASCE. (2005). “Minimum design loads for buildings and other structures.” ASCE/SEI 7-05, ASCE, Reston, Va.
ASTM. (2003a). “Standard test methods for direct moisture content measurement of wood and wood-base materials.” ASTM D 4442-92, ASTM, West Conshohocken, Pa.
ASTM. (2003b). “Standard test method for determining bending yield moment of nails.” ASTM F1575-03, ASTM, West Conshohocken, Pa.
ASTM. (2006a). “Standard test methods for cyclic (reversed) load test for shear resistance of walls for buildings.” ASTM E546-06, ASTM, West Conshohocken, Pa.
ASTM. (2006b). “Standard test methods for cyclic (reversed) load test for shear resistance of walls for buildings.” ASTM E2126-05, ASTM, West Conshohocken, Pa.
ASTM. (2006c). “Standard test methods for specific gravity of wood and wood-based materials.” ASTM D 2395-02, ASTM, West Conshohocken, Pa.
Dolan, J. D. (1989). “The dynamic response of timber shear walls.” Ph.D. dissertation, Univ. of British Columbia, Vancouver, B.C.
Dolan, J. D. (1994). “Proposed test method for dynamic properties of connections assembled with mechanical fasteners.” J. Test. Eval., 22(6), 542–547.
Hahney, T. (2000). “How log buildings resist lateral loads.” Log Building News, Vol. 32, 1–6, International Log Builders Assoc., Lumby, British Columbia, Canada.
International Code Council Evaluation Service, Inc. (ICC-ES). (2004). “Acceptance criteria for prefabricated wood shear panels.” AC 130, ICC-ES, Whittier, Calif.
International Code Council, Inc. (ICC). (2005). “ICC standard on log construction.” ICC/ANSI 400-2005, ICC, Country Club Hills, Ill.
International Code Council, Inc. (ICC). (2006). International Building Code 2006, ICC, Falls Church, Va.
Keegan, C. E., Chase, A., Shook, S., and Van Hooser, D. D. (2000). “Montana’s log home industry.” Montana Business Quarterly, 38(4), 2–9.
Krawinkler, H., Parisi, F., Ibarra, L., Ayoub, A., and Ricardo, M. (2001). Development of a testing protocol for wood frame structures (CUREE Publication No. W-02), CUREE, Richmond, Calif.
Langlois, J. D., Gupta, R., and Miller, T. H. (2004). “Effects on reference displacement and damage accumulation in wood shear walls.” J. Struct. Eng., 130(3), 470–479.
National Association of Home Builders (NAHB). (2007). NAHB Web site, ⟨http://www.nahb.org/generic.aspx?genericContentID=10227⟩ (Jan. 11, 2007).
Popovski, M. (2002). “Testing of lateral resistance of handcrafted log walls Phase I and II.” Forintek Canada Corp. Rep. No. 3512/3512A Prepared for International Log Builders Association (ILBA), Forintek Canada Corp., Vancouver, British Columbia, Canada.
Salenikovich, A. (2000). “The racking performance of light-frame shear walls.” Ph.D. dissertation, Virginia Tech.
Scott, R. J., Leichti, R. J., and Miller, T. M. (2005). “An experimental investigation of foundation anchorage details and base shear capacity for log buildings.” For. Prod. J., 55(4), 38–45.
van de Lindt, J. W. (2004). “Evolution of wood shear wall testing, modeling, and reliability analysis: Bibliography.” Pract. Period. Struct. Des. Constr., 9(1), 44–53.
Yeh, M. -C., Chiang, C. -L., and Lin, D. -T., (2006). “Effect of openings on the racking strength of structural log walls.” For. Prod. J., 56(11/12), 137–141.
Information & Authors
Information
Published In
Copyright
© 2010 ASCE.
History
Received: Feb 27, 2008
Accepted: Feb 9, 2009
Published online: Dec 15, 2009
Published in print: Jan 2010
Authors
Metrics & Citations
Metrics
Citations
Download citation
If you have the appropriate software installed, you can download article citation data to the citation manager of your choice. Simply select your manager software from the list below and click Download.