Experimental Investigation of Autoclaved Aerated Concrete Masonry
Publication: Journal of Materials in Civil Engineering
Volume 31, Issue 7
Abstract
The strength and stiffness characteristics of infill masonry wall significantly influence the behavior of reinforced concrete framed structures. Although such characteristics for conventional masonry infill walls, like clay and fly ash bricks, are well documented in the literature, experiments for the evaluation of similar properties for modern infill walls using autoclaved aerated concrete (AAC) blocks are limited. This paper reports the experimental results of an investigation of the structural properties of AAC block masonry required for mathematical modeling of AAC masonry-infilled framed structures. It also investigates some of the physical properties of AAC blocks that influence their structural properties and overall behavior.
Get full access to this article
View all available purchase options and get full access to this article.
References
ACI (American Concrete Institute). 2013. Building code requirements and specification for masonry structures and companion commentaries. ACI 530/530.1. Farmington Hills, MI: ACI.
Alexanderson, J. 1979. “Relations between structure and mechanical properties of autoclaved aerated concrete.” Cem. Concr. Res. 9 (4): 507–514. https://doi.org/10.1016/0008-8846(79)90049-8.
Aliabdo, A. A., A. E. M. Abd-Elmoaty, and H. H. Hassan. 2014. “Utilization of crushed clay brick in cellular concrete production.” Alexandria Eng. J. 53 (1): 119–130. https://doi.org/10.1016/j.aej.2013.11.005.
Andolsun, S. 2006. “Aerated concrete (AAC) and its complementary wall elements: Their compatibility in contemporary and historical wall sections.” M.Sc. thesis, Dept. of Architecture, Middle East Technical Univ.
ANSI (American National Standard Institute). 2012. American National Standard specifications for modified dry-set cement mortar. ANSI A118.4. New York: ANSI.
ASTM. 2000. Standard test method for measurement of masonry flexural bond strength. ASTM C1072. West Conshohocken, PA: ASTM.
ASTM. 2013. Standard test method for measurement of rate of absorption of water by hydraulic-cement concretes. ASTM C1585. West Conshohocken, PA: ASTM.
ASTM. 2017a. Standard specification for autoclaved aerated concrete (AAC). ASTM C1693. West Conshohocken, PA: ASTM.
ASTM. 2017b. Standard test methods for sampling and testing brick and structural clay tile. ASTM C67. West Conshohocken, PA: ASTM.
Atkinson, R. H., and J. L. Noland. 1983. “A proposed failure theory for brick masonry in compression.” In Proc., 3rd Canadian Masonry Symp. Mississauga, ON, Canada: Canada Masonry Design Centre.
BIS (Bureau Indian Standards). 1987. Code of practice for structural use of unreinforced masonry. IS 1905. New Delhi, India: BIS.
BIS (Bureau Indian Standards). 2005. Concrete masonry units, Part 3: Autoclaved cellular aerated concrete blocks. IS 2185. New Delhi, India: BIS.
Costa, A. A., A. Penna, and G. Magenes. 2011. “Seismic performance of autoclaved aerated concrete (AAC) masonry: From experimental testing of the in-plane capacity of walls to building response simulation.” J. Earthquake Eng. 15 (1): 1–31. https://doi.org/10.1080/13632461003642413.
Costa, A. A., A. Penna, G. Magenes, and A. Galasco. 2008. “Seismic performance assessment of autoclaved aerated concrete (AAC) masonry buildings.” In Proc., 14th World Conf. on Earthquake Engineering. Tokyo: International Association for Earthquake Engineering.
Drysdale, R. G., A. A. Hamid, and L. R. Baker. 1994. Masonry structures: Behavior and design, 5.1–5.17. Englewood Cliffs, NJ: Prentice-Hall.
Hanecka, K., and P. M. Msovsky. 1997. “The carbonation of autoclaved aerated concrete.” Cem. Concr. Res. 27 (4): 589–599. https://doi.org/10.1016/S0008-8846(97)00024-0.
Held, L., and C. Anderson. 1983. “The effect of sand grading on mortar and the tensile bond of brickwork specimens.” Proc., of the 8th Int. Load-Bearing Brickwork Symp. Stoke-on-Trent, UK: British Ceramic Society.
Hu, W., R. D. Neufeld, L. E. Vallejo, C. Kelly, and M. Latona. 1997. “Strength properties of autoclaved cellular concrete with high volume fly ash.” J. Energy Eng. 123 (2): 44–54. https://doi.org/10.1061/(ASCE)0733-9402(1997)123:2(44).
Imran, L., and A. Aryanto. 2009. “Behaviour of reinforced concrete frames infilled with lightweight materials under seismic loads.” Civ. Eng. Dimension 11 (2): 69–77.
Isu, N., H. Ishida, and T. Mitsuda. 1995. “Influence of quartz particle size on the chemical and mechanical properties of autoclaved aerated concrete: Tobermorite formation.” Cem. Concr. Res. 25 (2): 243–248. https://doi.org/10.1016/0008-8846(95)00003-8.
Jerman, M., M. Keppert, J. Vyborny, and R. Cerny. 2013. “Hygric, thermal and durability properties of autoclaved aerated concrete.” Constr. Build. Mater. 41 (Apr): 352–359. https://doi.org/10.1016/j.conbuildmat.2012.12.036.
Jos, R., and M. Lukito. 2011. “Influence of water absorption on properties of AAC and CLC lightweight concrete brick.” In Proc., 4th ASEAN Civil Engineering Conf. Yogyakarta, Indonesia: Universitas Gadjah Mada.
Kaushik, H. B., D. C. Rai, and S. K. Jain. 2007. “Stress–strain characteristics of clay brick masonry under uniaxial compression.” J. Mater. Civ. Eng. 19 (9): 728–739. https://doi.org/10.1061/(ASCE)0899-1561(2007)19:9(728).
Khalaf, F. M. 2005. “New test for determination of masonry tensile bond strength.” J. Mater. Civ. Eng. 17 (6): 725–732. https://doi.org/10.1061/(ASCE)0899-1561(2005)17:6(725).
Matthys, J. H., and R. L. Nelson. 1999. “Structural properties of autoclaved aerated concrete masonry. In Masonry: Materials, testing, and applications: STP 1356. West Conshohocken, PA: ASTM.
McNary, W. S., and D. P. Abrams. 1985. “Mechanics of masonry in compression.” J. Struct. Eng. 111 (4): 857–870. https://doi.org/10.1061/(ASCE)0733-9445(1985)111:4(857).
Morgan, J. W. 1977. “Brick absorption.” Archit. Sci. Rev. 20 (3–4): 66–68. https://doi.org/10.1080/00038628.1977.9696372.
Narayanan, N. 1999. “Influence of composition on the structure and properties of aerated concrete.” M.S. thesis, Dept. of Civil Engineering, Indian Institute of Technology Madras.
Odler, I., and M. Robler. 1985. “Investigations on the relationship between porosity, structure and strength of hydrated portland cement pastes: Effect of pore structure and of degree of hydration.” Cem. Concr. Res. 15 (3): 401–410. https://doi.org/10.1016/0008-8846(85)90113-9.
Penna, A., G. Magenes, G. M. Calvi, and A. A. Costa. 2008. “Seismic performance of AAC infill and bearing walls with different reinforcement solutions.” In Vol. 194 of Proc., 14th Int. Brick-Block Masonry Conf. (IB2MAC). Callaghan, Australia: Univ. of Newcastle.
Philip, J. R. 1957. “The theory of infiltration: 4. Sorptivity and algebraic infiltration equations.” Soil Sci. 84 (3): 257–264. https://doi.org/10.1097/00010694-195709000-00010.
Pospisil, F., J. Jambor, and J. Belko. 1992. “Unit weight reduction of fly ash aerated concrete.” In Proc., Advances in Autoclaved Aerated Concrete, 43–52. Rotterdam, Netherland: A.A. Balkema.
Riddington, J. R., and P. Jukes. 1994. “A masonry joint shear strength test method.” Proc. Inst. Civ. Eng. Struct. Build. 104 (3): 267–274. https://doi.org/10.1680/istbu.1994.26777.
RILEM. 1980. “Recommended tests to measure the deterioration of stone and to assess the effectiveness of treatment methods.” Mater. Struct. 13 (3): 175–253. https://doi.org/10.1007/BF02473564.
RILEM. 1993. Autoclaved aerated concrete: Properties, testing and design. London: Taylor & Francis.
Sarangapani, G., B. V. Venkatarama Reddy, and K. S. Jagadish. 2005. “Brick-mortar bond and masonry compressive strength.” J. Mater. Civ. Eng. 17 (2): 229–237. https://doi.org/10.1061/(ASCE)0899-1561(2005)17:2(229).
Siddiqui, U. A., H. Sucuoglu, and A. Yakut. 2015. “Seismic performance of gravity-load designed concrete frames infilled with low-strength masonry.” Earthquakes Struct. 8 (1): 19–35. https://doi.org/10.12989/eas.2015.8.1.019.
Singhal, V., and D. C. Rai. 2014. “Suitability of half scale burnt clay bricks for shake table tests on masonry walls.” J. Mater. Civ. Eng. 26 (4): 644–657. https://doi.org/10.1061/(ASCE)MT.1943-5533.0000861.
Sucuoglu, H., and U. A. Siddiqui. 2014. “Pseudo-dynamic testing and analytical modelling of AAC infilled RC frames.” J. Earthquake Eng. 18 (8): 1281–1301. https://doi.org/10.1080/13632469.2014.932723.
Taha, M. R., A. S. El-Diev, and N. G. Shrive. 2001. “Sorptivity: A surface absorption criterion for brick units: A proposal for the Canadian masonry standard.” In Proc., 9th Canadian Masonry Symp. Mississauga, ON, Canada: Canada Masonry Design Centre.
Tanner, J., J. Varela, M. Brightman, U. Cancino, J. Argudo, and R. Klinger. 2004. “Seismic performance and design of autoclaved aerated concrete (AAC) structural systems.” In Proc., 13th World Conf. on Earthquake Engineering. Tokyo: International Association for Earthquake Engineering.
Varela, J., J. Tanner, and R. Klinger. 2006. “Development of seismic force reduction and displacement amplification factors for autoclaved aerated concrete structures.” Earthquake Spectra 22 (1): 267–286. https://doi.org/10.1193/1.2166034.
Information & Authors
Information
Published In
Copyright
©2019 American Society of Civil Engineers.
History
Received: Jul 6, 2018
Accepted: Jan 16, 2019
Published online: Apr 27, 2019
Published in print: Jul 1, 2019
Discussion open until: Sep 27, 2019
Authors
Metrics & Citations
Metrics
Citations
Download citation
If you have the appropriate software installed, you can download article citation data to the citation manager of your choice. Simply select your manager software from the list below and click Download.