Lateral Performance of As-Built and Retrofitted Timber Diaphragm Fastener Connections
Publication: Journal of Materials in Civil Engineering
Volume 30, Issue 1
Abstract
The in-plane stiffness of timber diaphragms commonly found in vintage unreinforced masonry (URM) buildings is largely determined by the rigidity of the fastener connections. Currently in the literature, however, there is limited experimental data on the behavior of floorboard-to-joist connections, and consequently the aim of the present study was to supplement that knowledge. The existing data provided the paramount input parameters for the finite element modeling of timber diaphragms, in order to model and validate the results obtained from the experimental testing of full-scale timber diaphragms. The floorboard-to-joist connections were extracted from two vintage URM buildings and were tested using three different test setups to address various realistic loading configurations. In addition, the floorboard-to-joist connections were improved using new nails or new screws. Specimens comprising plywood or fire-rated gypsum-board panels connected to the salvaged floorboards or joists were also tested as a method for improving the overall diaphragm lateral behavior. The experimental study of timber diaphragm fastener connections consisted of 43 samples, of which the results are presented here.
Get full access to this article
View all available purchase options and get full access to this article.
Acknowledgments
The authors acknowledge the financial support from the Natural Hazards Research Platform (NHRP). Kevin Jiang, Mick Van Leeuwen, and Mark Byrami are the students and staff who participated in the various field and laboratory testing efforts. DML Builders Limited are thanked for providing access to the building located in Whanganui, New Zealand, and Mike Lake is thanked for providing access to the building located in Auckland, New Zealand.
References
ABK (Agbabian & Associates, S.B. Barnes & Associates, and Kariotis & Associates). (1981). Diaphragm testing. Methodology for mitigation of seismic hazards in existing unreinforced masonry buildings, El Segundo, CA.
AS (Australian Standard). (1998). “Strengthening existing buildings for earthquake.” AS 3826-1998, Australia.
ASCE. (2014). “Seismic evaluation and retrofit of existing buildings.” ASCE/SEI 41-13, Reston, VA.
AS/NZS (Australian/New Zealand Standard). (2008). “Structural plywood.” AS/NZS 2269:2008, Australia.
ASTM. (2013). “Standard test method for determining bending yield moment of nails.” ASTM F1575-03, West Conshohocken, PA.
Brignola, A., Pampanin, S., and Podestà, S. (2012). “Experimental evaluation of the in-plane stiffness of timber diaphragms.” Earthquake Spectra, 28(4), 1687–1709.
Building Regulation. (2012). “Building regulation 1992.” NSR 1992/150, Wellington, New Zealand.
Carroll, C. T., Leichti, R. J., and Clauson, M. (2010). “Wood materials, nails, and sheathing connections from early 20th century residential buildings.” J. Mater. Civ. Eng., 1122–1128.
Cavalli, A., Cibecchini, D., Togni, M., and Sousa, H. S. (2016). “A review on the mechanical properties of aged wood and salvaged timber.” Constr. Build. Mater., 114, 681–687.
CBI (Co-Ordinated Building Information). (2012). “GIB fire rated systems.”, New Zealand.
CEN (European Committee for Standardization). (1991). “Timber structures—Joints made with mechanical fasteners—General principles for the determination of strength and deformation characteristics.” EN 26891:1991, Brussels, Belgium.
CEN (European Committee for Standardization). (2001). “Timber structures—Test methods—Cyclic testing of joints made with mechanical fasteners.” EN 12512:2001, Brussels, Belgium.
CEN (European Committee for Standardization). (2012). “Timber structures. Structural timber and glued laminated timber. Determination of some physical and mechanical properties.” EN 408, Brussels, Belgium.
Giongo, I., Dizhur, D., Tomasi, R., and Ingham, J. M. (2014). “Field testing of flexible timber diaphragms in an existing vintage URM building.” J. Struct. Eng., D4014009.
Hsiao, J. K., and Tezcan, J. (2012). “Seismic retrofitting for chord reinforcement for unreinforced masonry historic buildings with flexible diaphragms.” J. Struct. Eng., 102–109.
Ingham, J., and Griffith, C. (2015). “Performance of unreinforced masonry buildings during the 2010 Darfield (Christchurch, NZ) earthquake.” Aust. J. Struct. Eng., 11(3), 207–224.
Kent, S. M., Leichti, R. J., Rovowsky, D. V., and Morrell, J. J. (2005). “Effects of decay on the cyclic properties of nailed connections.” J. Mater. Civ. Eng., 579–585.
McLain, T. E. (1975). “Curvilinear load-slip relations in laterally-loaded nailed joints.” Ph.D. thesis, Colorado State Univ., Fort Collins, CO.
NZSEE (New Zealand Society for Earthquake Engineering). (2015). Assessment and improvement of the structural performance of buildings in earthquakes—Section 10 revision seismic assessment of unreinforced masonry buildings, Wellington, New Zealand.
Wilson, A., Quenneville, P. J. H., and Ingham, J. M. (2014a). “In-plane orthotropic behavior of timber floor diaphragms in unreinforced masonry buildings.” J. Struct. Eng., 04013038.
Wilson, A., Quenneville, P. J. H., Moon, F. L., and Ingham, J. M. (2014b). “Lateral performance of nail connections from century old timber floor diaphragms.” J. Mater. Civ. Eng., 202–205.
Information & Authors
Information
Published In
Copyright
©2017 American Society of Civil Engineers.
History
Received: Feb 2, 2017
Accepted: Jun 14, 2017
Published online: Nov 8, 2017
Published in print: Jan 1, 2018
Discussion open until: Apr 8, 2018
Authors
Metrics & Citations
Metrics
Citations
Download citation
If you have the appropriate software installed, you can download article citation data to the citation manager of your choice. Simply select your manager software from the list below and click Download.