Hydraulic transient field tests have been conducted in a water distribution network. Existing transient models are applied to model the measured responses, but poor matches are obtained apart from the estimation of the initial rise of pressure. Possible reasons for these discrepancies include the effects of demands, entrained air, unsteady friction, friction losses associated with small lateral pipes, and mechanical damping caused by the interaction of pipes and joints with surrounding soils (including the effects of vibration and different degrees of restraint). These effects are systematically investigated by inclusion of the previously mentioned phenomena in conceptual transient models and calibration to the measured field responses. A mechanical damping-based conceptual transient model is shown to be the only model that can be accurately calibrated to the measured field responses.
Get full access to this article
View all available purchase options and get full access to this article.
References
Budny, D. D., Wiggert, D. C., and Hatfield, F. J. (1991). “Influence of structural damping on internal pressure during a transient pipe flow.” J. Fluids Eng., 113(3), 424–429.
Covas, D., Stoianov, I., Mano, J. F., Ramos, H., Graham, N., and Maksimovic, C. (2004). “The dynamic effect of pipe-wall viscoelasticity in hydraulic transients: Part I—Experimental analysis and creep characterisation.” J. Hydraul. Res., 42(5), 517.
Gally, M., Guney, M., and Rieuford, E. (1979). “Investigation of pressure transients in viscoelastic pipes.” J. Fluids Eng., 101, 495–499.
Kagawa, T., Lee, I., Kitagawa, A., and Takenaka, T. (1983). “High speed and accurate computing method of frequency-dependent friction in laminar pipe flow for characteristics method.” T. Jpn. Soc. Mech. Eng., 49(447), 2638–2644 (in Japanese).
Karney, B. W., and Fillion, Y. R. (2003). “Energy dissipation mechanisms in water distribution systems.” Proc. 4th ASME/JSME Joint Fluids Eng. Conf., 2(Part D), ASME, New York, 2771–2778.
Kwon, H. J. (2007). “Computer simulations of transient flow in a real city water distribution system.” KSCE J. Civ. Eng., 11(1), 43–49.
McInnis, D., and Karney, B. W. (1995). “Transients in distribution networks: Field tests and demand models.” J. Hydraul. Eng., 121(3), 218–231.
Stephens, M. L. (2008). “Transient response analysis for fault detection and pipeline wall condition assessment in field water transmission and distribution pipelines and networks.” Ph.D. thesis, School of Civil, Environmental and Mining Engineering, Univ. of Adelaide, Adelaide, Australia.
Vardy, A. E., and Brown, J. M. B. (1995). “Transient, turbulent, smooth pipe friction.” J. Hydraul. Res., 33(4), 435.
Vardy, A. E., and Brown, J. M. B. (2004). “Transient turbulent friction in fully rough pipe flows.” J. Sound Vib., 270(1–2), 233–257.
Vitkovsky, J. P., Stephens, M., Lambert, M. F., Simpson, A. R., and Bergant, A. (2004). “Efficient and accurate calculation of Zielke and Vardy-Brown unsteady friction in pipe transients.” 9th Int. Conf. on Pressure Surges, BHR Group, Chester, England.
Williams, D. J. (1977). “Waterhammer in non-rigid pipes: Precursor waves and mechanical damping.” J. Mech. Eng. Sci., 19(6), 237–242.
Wylie, E. B. (1984). “Simulation of vaporous and gaseous cavitation.” J. Fluids Eng., 106, 307–311.
Zielke, W. (1968). “Frequency-dependent friction in transient pipe flow.” J. Basic Eng., 90(1), 109–115.
Information & Authors
Information
Published In
Copyright
© 2011 American Society of Civil Engineers.
History
Received: Feb 26, 2010
Accepted: Feb 25, 2011
Published online: Mar 4, 2011
Published in print: Oct 1, 2011
Authors
Metrics & Citations
Metrics
Citations
Download citation
If you have the appropriate software installed, you can download article citation data to the citation manager of your choice. Simply select your manager software from the list below and click Download.