Technical Papers
Feb 8, 2022

Numerical Simulation of By-Product Fuel Combustion in a Tangential Gas-Fired Boiler: Effect of Proportion and Angle on Coke Oven Gas

Publication: Journal of Energy Engineering
Volume 148, Issue 2

Abstract

The use of low calorific value residual gas generated in the metallurgical process, including blast furnace gas (BFG), coke oven gas (COG), and Linz-Donawitz gas (LDG), to replace coal can save energy and reduce pollutant emissions. Here, a numeral model was developed to stimulate the combustion characteristics of a 75  t/h tangential combustion boiler burning a mixture of BFG and COG. The effect of COG burners downdip on temperature distribution, flow field, NOx emission, and flue gas temperature deviation was analyzed and discussed under two different COG input heat proportions (20% and 30%). The numerical simulation was performed in Fluent and validated by field experiments. The simulation result showed that, under COG input heat proportions of 20% and 30%, the flue gas temperature in the horizontal gas pass slightly decreased when the COG burners tilted down. The area with a temperature greater than 1,500°C (1,773.15 K) near the COG burners also shrank, and the NOx emission under the two fuel schemes slumped by 46.8  mg/m3 and 82.8  mg/m3, respectively. Although increasing the proportion of COG input heat aggravated the NOx pollution, tilting the COG burners down offset this negative influence. Furthermore, tilting the COG burners down slightly reduced the swirling intensity of the furnace and improved the deviation in the horizontal gas pass. Blending more COG reduced the swirling intensity in the furnace and the velocity deviation in the horizontal gas pass. In general, tilting the COG burners down reduced pollution emissions and superheater deviation problems when more COG was mixed in the boiler to improve the combustion of BFG.

Get full access to this article

View all available purchase options and get full access to this article.

Data Availability Statement

All data, models, or code that support the findings of this study are available from the corresponding author upon reasonable request.

References

Abdul Jameel, A. G., C. Dahiphale, A. B. S. Alquaity, U. Zahid, and S. Jayanti. 2021. “Numerical simulation of coal combustion in a tangential pulverized boiler: Effect of burner vertical tilt angle.” Arabian J. Sci. Eng. 2021 (Apr): 1–14. https://doi.org/10.1007/s13369-021-05613-8.
Chang, J., X. Wang, Z. Zhou, H. Chen, and Y. Niu. 2021. “CFD modeling of hydrodynamics, combustion and NOx emission in a tangentially fired pulverized-coal boiler at low load operating conditions.” Adv. Powder Technol. 32 (2): 290–303. https://doi.org/10.1016/j.apt.2020.12.008.
Chen, S., B. He, D. He, Y. Cao, G. Ding, X. Liu, Z. Duan, X. Zhang, J. Song, and X. Li. 2017. “Numerical investigations on different tangential arrangements of burners for a 600 MW utility boiler.” Energy 122 (Mar): 287–300. https://doi.org/10.1016/j.energy.2017.01.093.
Giles, A. P., R. Marsh, P. J. Bowen, and A. Valera-Medina. 2016. “Applicability of the Peclet number approach to blow-off and flashback limits of common steelworks process gases.” Fuel 182 (Oct): 531–540. https://doi.org/10.1016/j.fuel.2016.05.082.
Hanson, R. K., and S. Salimian. 1984. “Survey of rate constants in the N/H/O system.” In Combustion chemistry, 361–421. New York: Springer.
Hou, S. S., C. H. Chen, C. Y. Chang, C. W. Wu, J. J. Ou, and T. H. Lin. 2011. “Firing blast furnace gas without support fuel in steel mill boilers.” Energy Convers. Manage. 52 (7): 2758–2767. https://doi.org/10.1016/j.enconman.2011.02.009.
Jin, W., C. Geng, Y. Wang, H. Ma, Y. Dong, and F. Si. 2021. “Combined effects of yaw and tilt angles of separated overfire air on the combustion characteristics in a 1,000 MW coal-fired boiler: A numerical study.” Korean J. Chem. Eng. 38 (4): 771–787. https://doi.org/10.1007/s11814-021-0745-0.
Li, C., H. Tang, L. Jing, and M. Zhu. 2016. “Investigations of the stabilities of piloted flames using blast furnace gas.” J. Eng. Gas Turbines Power 138 (3): 031505. https://doi.org/10.1115/1.4031348.
Li, Z., Z. Miao, X. Shen, and J. Li. 2018. “Effects of momentum ratio and velocity difference on combustion performance in lignite-fired pulverized boiler.” Energy 165 (Dec): 825–839. https://doi.org/10.1016/j.energy.2018.09.082.
Liu, H., L. Zhang, X. Han, S. Zhou, P. Yu, and D. Che. 2020. “Effects of lignite predrying degree on the combustion and NO generation in a 600-MW lignite-fired boiler.” J. Energy Eng. 146 (6): 04020070. https://doi.org/10.1061/(ASCE)EY.1943-7897.0000715.
Liu, Y., W. Fan, and Y. Li. 2016. “Numerical investigation of air-staged combustion emphasizing char gasification and gas temperature deviation in a large-scale, tangentially fired pulverized-coal boiler.” Appl. Energy 177 (Sep): 323–334. https://doi.org/10.1016/j.apenergy.2016.05.135.
Liu, Y. C., W. D. Fan, and M. Z. Wu. 2017. “Experimental and numerical studies on the gas velocity deviation in a 600 MWe tangentially fired boiler.” Appl. Therm. Eng. 110 (Jan): 553–563. https://doi.org/10.1016/j.applthermaleng.2016.08.185.
Musial, D. 2020. “Coke and blast furnace gases: Ecological and economic benefits of use in heating furnaces.” Combust. Sci. Technol. 192 (6): 1015–1027. https://doi.org/10.1080/00102202.2019.1605990.
Park, H. Y., S. H. Baek, H. H. Kim, Y. J. Kim, T. H. Kim, H. S. Lim, and D. S. Kang. 2016. “Reduction of main steam temperature deviation in a tangentially coal-fired, two pass boiler.” Fuel 166 (Feb): 509–516. https://doi.org/10.1016/j.fuel.2015.11.005.
Park, H. Y., S. H. Baek, Y. J. Kim, T. H. Kim, D. S. Kang, and D. W. Kim. 2013. “Numerical and experimental investigations on the gas temperature deviation in a large scale, advanced low NOx, tangentially fired pulverized coal boiler.” Fuel 104 (Feb): 641–646. https://doi.org/10.1016/j.fuel.2012.06.091.
Qian, Y., L. Scherer, A. Tukker, and P. Behrens. 2020. “China’s potential SO2 emissions from coal by 2050.” Energy Policy 147 (Dec): 111856. https://doi.org/10.1016/j.enpol.2020.111856.
Sun, S., W. Liu, W. Guan, S. Zhu, J. Jia, X. Wu, R. Lei, T. Jia, and Y. He. 2021. “Effects of air pollution control devices on volatile organic compounds reduction in coal-fired power plants.” Sci. Total Environ. 782 (Aug): 146828. https://doi.org/10.1016/j.scitotenv.2021.146828.
Sun, W., W. Zhong, A. Yu, L. Liu, and Y. Qian. 2016. “Numerical investigation on the flow, combustion, and NOx emission characteristics in a 660 MWe tangential firing ultra-supercritical boiler.” Adv. Mech. Eng. 8 (2): 168781401663072. https://doi.org/10.1177/1687814016630729.
Tan, P., Q. Fang, S. Zhao, C. Yin, C. Zhang, H. Zhao, and G. Chen. 2018. “Causes and mitigation of gas temperature deviation in tangentially fired tower-type boilers.” Appl. Therm. Eng. 139 (Jul): 135–143. https://doi.org/10.1016/j.applthermaleng.2018.04.131.
Tan, P., D. Tian, Q. Fang, L. Ma, C. Zhang, G. Chen, L. Zhong, and H. Zhang. 2017. “Effects of burner tilt angle on the combustion and NOx emission characteristics of a 700 MWe deep-air-staged tangentially pulverized-coal-fired boiler.” Fuel 196 (May): 314–324. https://doi.org/10.1016/j.fuel.2017.02.009.
Tian, D., L. Zhong, P. Tan, L. Ma, Q. Fang, C. Zhang, D. Zhang, and G. Chen. 2015. “Influence of vertical burner tilt angle on the gas temperature deviation in a 700 MW low NOx tangentially fired pulverised-coal boiler.” Fuel Process. Technol. 138 (Oct): 616–628. https://doi.org/10.1016/j.fuproc.2015.07.002.
Wang, Y., J. Li, S. Huang, X. Huang, W. Hu, J. Pu, and M. Xu. 2021. “Evaluation of NOx removal from flue gas and Fe(II)EDTA regeneration using a novel BTF-ABR integrated system.” J. Hazard. Mater. 415 (Aug): 125741. https://doi.org/10.1016/j.jhazmat.2021.125741.
Wang, Y., and Y. Zhou. 2020. “Numerical optimization of the influence of multiple deep air-staged combustion on the NOx emission in an opposed firing utility boiler using lean coal.” Fuel 269 (Jun): 116996. https://doi.org/10.1016/j.fuel.2019.116996.
Xu, M., B. Lin, and S. Wang. 2021. “Towards energy conservation by improving energy efficiency? Evidence from China’s metallurgical industry.” Energy 216 (Feb): 119255. https://doi.org/10.1016/j.energy.2020.119255.
Yan, L., B. He, F. Yao, R. Yang, X. Pei, C. Wang, and J. Song. 2012. “Numerical simulation of a 600 MW utility boiler with different tangential arrangements of burners.” Energy Fuels 26 (9): 5491–5502. https://doi.org/10.1021/ef300929v.
Yao, Z., J. Liu, Z. Qiu, W. Pan, and Z. Wu. 2021. “Numerical investigation of 700 °C boiler flue gas thermal deviation based on orthogonal experiment.” Fuel 295 (Jul): 120510. https://doi.org/10.1016/j.fuel.2021.120510.
Yu, C., W. Xiong, H. Ma, J. Zhou, F. Si, X. Jiang, and X. Fang. 2019. “Numerical investigation of combustion optimization in a tangential firing boiler considering steam tube overheating.” Appl. Therm. Eng. 154 (May): 87–101. https://doi.org/10.1016/j.applthermaleng.2019.03.074.
Zha, Q., D. Li, C. Wang, and D. Che. 2017. “Numerical evaluation of heat transfer and NOx emissions under deep-air-staging conditions within a 600 MWe tangentially fired pulverized-coal boiler.” Appl. Therm. Eng. 116 (Apr): 170–181. https://doi.org/10.1016/j.applthermaleng.2016.12.088.
Zhou, Y., T. Xu, S. Hui, and M. Zhang. 2009. “Experimental and numerical study on the flow fields in upper furnace for large scale tangentially fired boilers.” Appl. Therm. Eng. 29 (4): 732–739. https://doi.org/10.1016/j.applthermaleng.2008.03.047.
Ziębik, A., M. Warzyc, and P. Gładysz. 2014. “Determination of the optimal structure of repowering a metallurgical CHP plant fired with technological fuel gases.” Arch. Metall. Mater. 59 (1): 105–116. https://doi.org/10.2478/amm-2014-0017.

Information & Authors

Information

Published In

Go to Journal of Energy Engineering
Journal of Energy Engineering
Volume 148Issue 2April 2022

History

Received: Aug 24, 2021
Accepted: Dec 5, 2021
Published online: Feb 8, 2022
Published in print: Apr 1, 2022
Discussion open until: Jul 8, 2022

Permissions

Request permissions for this article.

Authors

Affiliations

Zhengming Yi [email protected]
Professor, State Key Laboratory of Refractories and Metallurgy, Wuhan Univ. of Science and Technology, Wuhan 430081, China (corresponding author). Email: [email protected]
Xuman Hu
Master’s Student, Key Laboratory for Ferrous Metallurgy and Resources Utilization of Ministry of Education, Wuhan Univ. of Science and Technology, Wuhan 430081, China.

Metrics & Citations

Metrics

Citations

Download citation

If you have the appropriate software installed, you can download article citation data to the citation manager of your choice. Simply select your manager software from the list below and click Download.

Cited by

  • Usage of Converter Gas as a Substitute Fuel for a Tunnel Furnace in Steelworks, Materials, 10.3390/ma15145054, 15, 14, (5054), (2022).
  • Study on Combustion Characteristics and NOx Formation in 600 MW Coal-Fired Boiler Based on Numerical Simulation, Energies, 10.3390/en16010262, 16, 1, (262), (2022).

View Options

Get Access

Access content

Please select your options to get access

Log in/Register Log in via your institution (Shibboleth)
ASCE Members: Please log in to see member pricing

Purchase

Save for later Information on ASCE Library Cards
ASCE Library Cards let you download journal articles, proceedings papers, and available book chapters across the entire ASCE Library platform. ASCE Library Cards remain active for 24 months or until all downloads are used. Note: This content will be debited as one download at time of checkout.

Terms of Use: ASCE Library Cards are for individual, personal use only. Reselling, republishing, or forwarding the materials to libraries or reading rooms is prohibited.
ASCE Library Card (5 downloads)
$105.00
Add to cart
ASCE Library Card (20 downloads)
$280.00
Add to cart
Buy Single Article
$35.00
Add to cart

Get Access

Access content

Please select your options to get access

Log in/Register Log in via your institution (Shibboleth)
ASCE Members: Please log in to see member pricing

Purchase

Save for later Information on ASCE Library Cards
ASCE Library Cards let you download journal articles, proceedings papers, and available book chapters across the entire ASCE Library platform. ASCE Library Cards remain active for 24 months or until all downloads are used. Note: This content will be debited as one download at time of checkout.

Terms of Use: ASCE Library Cards are for individual, personal use only. Reselling, republishing, or forwarding the materials to libraries or reading rooms is prohibited.
ASCE Library Card (5 downloads)
$105.00
Add to cart
ASCE Library Card (20 downloads)
$280.00
Add to cart
Buy Single Article
$35.00
Add to cart

Media

Figures

Other

Tables

Share

Share

Copy the content Link

Share with email

Email a colleague

Share