Probabilistic Capacity Models for Corroding Posttensioning Strands Calibrated Using Laboratory Results
Publication: Journal of Engineering Mechanics
Volume 135, Issue 9
Abstract
The presence of air voids, moisture, and chlorides inside tendons or ducts was cited as a reason for the early age strand corrosion and failure in the Mid-bay, Sunshine Skyway, and Niles Channel posttensioned (PT) bridges in Florida, United States. Although rare, these incidents call for frequent inspection and structural reliability assessment of PT bridges exposed to moisture and chlorides. This paper develops and presents probabilistic strand capacity models that are needed to assess the structural reliability of such PT bridges and recommends a time frequency of inspection. A total of 384 strand test specimens were exposed to various void, moisture, and chloride concentration conditions for 12 and 21 months; the remaining tension capacities were then determined. Using this experimental data and a Bayesian approach, six probabilistic capacity models were developed based on the void type. The mean absolute percentage errors of these models are less than 4%, indicating that reasonably accurate prediction of the strand capacity is possible, when void, aggressive moisture, and chloride conditions are present.
Get full access to this article
View all available purchase options and get full access to this article.
Acknowledgments
This research was performed at the Texas Transportation Institute and Zachry Department of Civil Engineering, Texas A&M University, College Station, Texas, through a sponsored project from the Texas Department of Transportation (TxDOT), Austin, Tex. This support is much appreciated. Continuous support from Keith Ramsey (program coordinator), Maxine Jacoby (project director), Brian Merrill, Dean Van Landuyt, Kenneth Ozuna, Steve Strmiska, Tom Rummel, and other TxDOT engineers are acknowledged.
References
Akgul, F., and Frangopol, D. M. (2004). “Lifetime performance analysis of existing prestressed concrete bridge superstructures.” J. Struct. Eng., 130(12), 1889–1903.
American Concrete Institute (ACI). (2003). “Protection of metals in concrete against corrosion.” ACI 222R-03, Farmington Hills, Mich.
American Segmental Bridge Institute (ASBI). (2000). Interim statement on grouting practices, American Segmental Bridge Institute, Phoenix.
ASTM. (2006). “Standard specification for steel strand, uncoated seven wire for prestressed concrete.” A416/A416M–06, West Conshohocken, Pa.
Box, G. E. P., and Tiao, G. C. (1992). Bayesian inference in statistical analysis, Addison-Wesley, Reading, Mass., 113–122.
Florida DOT (FDOT). (2001a). “Mid-bay bridge post-tensioning evaluation.” Final Rep. Prepared for Florida Dept. of Transportation, Corven Engineering, Inc., Tallahassee, Fla.
Florida DOT (FDOT). (2001b). “Sunshine Skyway Bridge posttensioned tendons investigation.” Rep. Prepared for Florida Dept. of Transportation, Parsons Brinckerhoff Quade and Douglas, Inc., Tallahassee, Fla.
Gardoni, P. G., Der Kiureghian, A., and Mosalam, K. M. (2002). “Probabilistic capacity models and fragility estimates for reinforced concrete columns based on experimental observations.” J. Eng. Mech., 128(10), 1024–1038.
Melchers, R. E. (2003). “Modeling of marine immersion corrosion for mild and low-alloy steels. Part 1: Phenomenological model.” Corrosion (Houston), 59(4), 319–334.
National Cooperative Highway Research Program (NCHRP). (1998). Durability of precast segmental bridges, R. W. Poston, and J. P. Wouters, eds., Transportation Research Record. 15, Transportation Research Board, Washington, D.C.
Pillai, R. G. (2009). “Electrochemical characterization and time-variant structural reliability assessments of post-tensioned, segmental concrete bridges.” Ph.D. dissertation, Zachry Dept. of Civil Engineering, Texas A&M Univ., College Station, Texas
Poston, W. R., Frank, K. H., and West, J. S. (2003). “Enduring strength.” Civ. Eng. (N.Y.), 73(9), 58–63.
Post-Tensioning Institute (PTI). (1998). Acceptance standards for post-tensioning systems, Phoenix.
Post-Tensioning Institute (PTI). (2003). Specification for grouting of post-tensioned structures, Phoenix.
Ryan, T. P. (2007). Modern engineering statistics, Wiley-Interscience, Hoboken, N.J.
Schupack, M. (2004). “PT grout: Bleedwater voids.” Concr. Int., 26(8), 69–77.
Trejo, D., Pillai, R. G., Hueste, M. D., Reinschmidt, K., and Gardoni, P. (2009a). “Parameters influencing corrosion and tension capacity of post-tensioning strands.”ACI Mater. J., 106(2), 144–153 .
Trejo, D., Hueste, M. D., Gardoni, P., Pillai, R. G., Reinschmidt, K., Kataria, S., Im, S., Gamble, M., and Hurlebaus, S. (2009b). “Effects of voids in grouted, posttensioned, concrete bridge construction.” Rep. No. 0–4588, Texas Transportation Institute, Texas Dept. of Transportation, Austin, Tex., ⟨http://tti.tamu.edu/documents/0-4588-1-Vol1.pdf⟩.
Woodward, R. J., Cullington, D. W., and Lane, J. S., and (2001). “Strategies for the management of posttensioned concrete bridges.” Current and future trends in bridge design, construction, and maintenance—2, P. C. Das, D. M. Frangopol, and A. S. Nowak, eds., Thomas Telford, London, 23–32.
Information & Authors
Information
Published In
Copyright
© 2009 ASCE.
History
Received: Mar 1, 2008
Accepted: Jan 14, 2009
Published online: Mar 6, 2009
Published in print: Sep 2009
Authors
Metrics & Citations
Metrics
Citations
Download citation
If you have the appropriate software installed, you can download article citation data to the citation manager of your choice. Simply select your manager software from the list below and click Download.