Baseline Mass-Transfer Coefficient and Interpretation of Nonsteady State Submerged Bubble-Oxygen Transfer Data
Publication: Journal of Environmental Engineering
Volume 146, Issue 1
Abstract
Numerous testing of data reported in the relevant scientific literature widely available to the public has led to the discovery of several physical mathematical models in nature applicable to the subject of oxygenation in water from submerged bubble aeration. The mass transfer coefficient commonly symbolized as is the product of the overall liquid film coefficient and the overall gas-liquid interfacial area that the gas flux passes through, expressed by the letter . The rate of mass transfer (the rate at which the solute gas dissolves into a given liquid) is a function of the mass transfer coefficient and the driving force exerted against the fluid being aerated. In a nonsteady state test where the oxygen content of the water is usually lowered to approximately zero prior to initiating the test, the driving force gradually diminishes as the dissolved oxygen increases until it reaches saturation. Given that is a function of many variables, in order to have a unified test result, it is necessary to create a baseline mass transfer coefficient , so that all tests will have the same measured baseline. is an exponential function of this new coefficient and dependent on the height of the liquid column through which the gas flow stream passes. The mass transfer coefficient is dependent on the gas average flow rate () passing through the liquid column. is expressed in terms of volume of gas per unit time and is calculated by the universal gas law, or Boyle’s Law, if the liquid temperature is uniform throughout the liquid column, taking the arithmetic mean of the flow rates over the tank column. is directly proportional to this averaged gas flow rate to power , where is usually less than unity for water in a fixed column height and a fixed gas supply rate at standard conditions. This paper provides case studies that verify this concept of a standardized specific baseline mass transfer coefficient that is applicable to submerged bubble aeration tests.
Get full access to this article
View all available purchase options and get full access to this article.
Data Availability Statement
Some or all data, models, or code generated or used during the study are available from the corresponding author by request: Barber’s experimental data (Barber 2014), Stenstrom’s experimental data (Stenstrom 2001), and Yunt et al.’s test data (Yunt et al. 1980).
References
Ahlert, R. C. 1997. Process dynamics in environmental systems. Edited by J. W. Walter, Jr. and A. D. Francis, 1–943. New York: Wiley. https://doi.org/10.1002/ep.3300160107.
ASCE. 1997. Standard guidelines for in-process oxygen transfer testing. 18-96. Reston, VA: ASCE.
ASCE. 2007. Measurement of oxygen transfer in clean water. Standard 2-06. Reston, VA: ASCE.
Ashley, K. I., D. S. Mavinic, and K. J. Hall. 2008. “Effect of orifice diameter, depth of air injection, and air flow rate on oxygen transfer in a pilot-scale, full lift, hypolimnetic aerator.” Can. J. Civ. Eng. 36 (1): 137–147. https://doi.org/10.1139/S08-047.
Baillod, C. R. 1979. “Review of oxygen transfer model refinements and data interpretation.” In Proc., Workshop toward an Oxygen Transfer Standard, edited by W. C. Boyle, 17–26. Cincinnati: USEPA.
Barber, T. W. 2014. “Superoxygenation: Analysis of oxygen transfer design parameters using high purity oxygen and a pressurized aeration column.” Ph.D. dissertation, Univ. of British Columbia.
Boon, A. G. 1979. Oxygen transfer in the activated-sludge process. Stevenage, UK: Water Research Centre, Stevenage Laboratory.
DeMoyer, C. D., E. L. Schierholz, J. S. Gulliver, and S. C. Wilhelms. 2002. “Impact of bubble and free surface oxygen transfer on diffused aeration systems.” Water Res. 37 (8): 1890–1904.
Eckenfelder, W. W., Jr. 1966. Industrial water pollution control. New York: McGraw-Hill.
Eckenfelder, W. W. 1970. Water pollution control: Experimental procedures for process design. Austin, TX: Pemberton Press.
EPA. 1988. Project summary: Aeration equipment evaluation. Phase I: Clean water test results. EPA/600/S2-88/022. Cincinnati: Water Engineering Research Laboratory.
Houck, D. H., and A. G. Boon. 1980. Survey and evaluation of fine bubble dome diffuser aeration equipment. Springfield, VA: National Technical Information Service.
Hwang, H. J., and M. K. Stenstrom. 1985. “Evaluation of fine-bubble alpha factors in near full-scale equipment.” J. Water Pollut. Control Fed. 57 (12): 1142–1151. https://doi.org/10.2307/25042816.
Jiang, P., and M. K. Stenstrom. 2012. “Oxygen transfer parameter estimation: Impact of methodology.” J. Environ. Eng. 138 (2): 137–142. https://doi.org/10.1061/(ASCE)EE.1943-7870.0000456.
Lee, J. 2017. “Development of a model to determine mass transfer coefficient and oxygen solubility in bioreactors.” Heliyon 3 (2): e00248. https://doi.org/10.1016/j.heliyon.2017.e00248.
Lee, J. 2018. “Development of a model to determine the baseline mass transfer coefficient in bioreactors (Aeration Tanks).” Water Environ. Res. 90 (12): 2126. https://doi.org/10.2175/106143017X15131012187999.
McGinnis, D. F., and J. C. Little. 2002. “Predicting diffused-bubble oxygen transfer rate using the discrete-bubble model.” Water Res. 36 (18): 4627–4635. https://doi.org/10.1016/S0043-1354(02)00175-6.
Rosso, D., and M. K. Stenstrom. 2006. Alpha factors in full-scale wastewater aeration systems. Alexandria, VA: Water Environment Foundation.
Schierholz, E. L., J. S. Gulliver, S. C. Wilhelms, and H. E. Henneman. 2006. “Gas Transfer from air diffusers.” Water Res. 40 (5): 1018–1026. https://doi.org/10.1016/j.watres.2005.12.033.
Schroeder, E. D. 1977. Water and wastewater treatment. Tokyo: McGraw-Hill.
Stenstrom, M. K. 2001. “Oxygen transfer report: Clean water testing (in accordance with latest ASCE standards) for Air Diffusion Systems submerged fine bubble diffusers on March 7, 8, 9, & 10 in 2001.” Accessed August 29, 2001. http://www.aqua-sierra.com/wp-content/uploads/ads-full-oxygen-report.pdf.
Yunt, F. W., T. O. Hancuff, and R. C. Brenner. 1980. Aeration equipment evaluation. Phase 1: Clean water test results. Cincinnati: USEPA.
Zhou, X., Y. Wu, H. Shi, and Y. Song. 2012. “Evaluation of oxygen transfer parameters of fine-bubble aeration system in plug flow aeration tank of wastewater treatment plant.” J. Environ. Sci. 25 (2): 295–301. https://doi.org/10.1016/S1001-0742(12)60062-X.
Information & Authors
Information
Published In
Copyright
©2019 American Society of Civil Engineers.
History
Received: Feb 22, 2019
Accepted: May 28, 2019
Published online: Nov 15, 2019
Published in print: Jan 1, 2020
Discussion open until: Apr 15, 2020
Authors
Metrics & Citations
Metrics
Citations
Download citation
If you have the appropriate software installed, you can download article citation data to the citation manager of your choice. Simply select your manager software from the list below and click Download.