Disputes and repairs due to window condensation problems frequently occur after the completion of apartments. However, most repairs are performed individually and confidentially by construction participants, who are forced to minimize economic losses. Thus, actual cases of inspection and repair for condensation defects have rarely been addressed in public even though condensation on windows remains the primary cause of defect disputes. This study aims to contribute to the resolution of similar disputes by presenting an actual case of a new apartment complex in which defect disputes arose from window condensation; the condensation resistance performance was inspected, and repair measures were proposed. On-site measurements and mock-up tests were performed. The results demonstrated that the -factor satisfied its required specifications but that the temperature difference ratio did not satisfy the requirements. Repair measures were proposed and evaluated; the combination of adding sealant, double glazing near the existing glazing, and an insulation cover on the frame was found to be effective. These repair measures were applied to the apartment complex and the number of condensation complaints decreased significantly.
Get full access to this article
View all available purchase options and get full access to this article.
Acknowledgments
This research was supported by a Grant (18RERP-B082204-05) from the Residential Environment Research Program funded by the Ministry of Land, Infrastructure and Transport of the Korean government.
References
AAMA (American Architectural Manufacturers Association). 2009. Voluntary test method for thermal transmittance and condensation resistance of windows, doors and glazed wall sections. Reed City, MI: AAMA.
Almeida, R. M. S. F., and E. Barreira. 2017. “Condensation and mold risk evaluation in a gymnasium: In situ measurements and numerical simulation.” J. Perform. Constr. Facil. 31 (5): 04017049. https://doi.org/10.1061/(ASCE)CF.1943-5509.0001047.
Bakonyi, D., and G. Dobszay. 2016. “Simulation aided optimization of a historic window’s refurbishment.” Energy Build. 126: 51–69. https://doi.org/10.1016/j.enbuild.2016.05.005.
Balaras, C. A., and A. A. Argiriou. 2002. “Infrared thermography for building diagnostics.” Energy Build. 34 (2): 171–183. https://doi.org/10.1016/S0378-7788(01)00105-0.
Baldinelli, G., and F. Bianchi. 2014. “Windows thermal resistance: Infrared thermography aided comparative analysis among finite volumes simulations and experimental methods.” Appl. Energy 136: 250–258. https://doi.org/10.1016/j.apenergy.2014.09.021.
Carlos, J. S. 2017. “Optimizing the ventilated double window for solar collection.” Solar Energy 150: 454–462. https://doi.org/10.1016/j.solener.2017.04.063.
Cho, W., S. Iwamoto, and S. Kato. 2016. “Condensation risk due to variations in airtightness and thermal insulation of an office building in warm and wet climate.” Energies 9 (11): 875. https://doi.org/10.3390/en9110875.
Hien, W. N., W. Liping, A. N. Chandra, A. R. Pandey, and W. Xiaolin. 2005. “Effects of double glazed facade on energy consumption, thermal comfort and condensation for a typical office building in Singapore.” Energy Build. 37 (6): 563–572. https://doi.org/10.1016/j.enbuild.2004.08.004.
Ismail, K. A. R., and J. R. Henríquez. 2006. “Simplified model for a ventilated glass window under forced air flow conditions.” Appl. Therm. Eng. 26 (2): 295–302. https://doi.org/10.1016/j.applthermaleng.2005.04.023.
ISO. 2003. Thermal performance of windows, doors and shading devices—Detailed calculations. Geneva: ISO.
ISO. 2007. Thermal bridges in building construction—Heat flows and surface temperatures—Detailed calculations. Geneva: ISO.
Kim, J., T. Kim, and S.-B. Leigh. 2011. “Double window system with ventilation slits to prevent window surface condensation in residential buildings.” Energy Build. 43 (11): 3120–3130. https://doi.org/10.1016/j.enbuild.2011.08.012.
Korea Land and Housing Corporation. 2007. Construction specifications, 32325 PVC framed window. Jinju, Korea: Korea Land and Housing Corporation.
Korean Agency for Technology and Standards. 2004. Test method of dew condensation for windows and doors. Chungcheongbuk-do, Korea: Korean Agency for Technology and Standards.
Korean Agency for Technology and Standards. 2008. Test method of thermal resistance for windows and doors. Korea: Korean Agency for Technology and Standards.
Lawrence Berkeley National Laboratory. 2011. THERM 6.3 material library. Berkeley, CA: Lawrence Berkeley National Laboratory.
Liu, M., K. B. Wittchen, P. K. Heiselberg, and F. V. Winther. 2013. “Development of a simplified and dynamic method for double glazing façade with night insulation and validated by full-scale façade element.” Energy Build. 58: 163–171. https://doi.org/10.1016/j.enbuild.2012.11.031.
Ministry of Land Infrastructure and Transport. 2008. Korean code for energy-efficient building design. Sejong, Korea: Ministry of Land, Infrastructure and Transport.
Ministry of Land Infrastructure and Transport. 2013. Korean design standard for preventing condensation in apartment buildings. Sejong, Korea: Ministry of Land, Infrastructure and Transport.
National Fenestration Rating Council. 2010. Procedure for determining fenestration product condensation resistance values. Greenbelt, MD: National Fenestration Rating Council.
National Fenestration Rating Council. 2014. Procedure for determining fenestration product U-factors. Greenbelt, MD: National Fenestration Rating Council.
Onur, N., M. Sivrioğlu, and O. Turgut. 1996. “An experimental study on air window collector having a vertical blind for active solar heating.” Solar Energy 57 (5): 375–380. https://doi.org/10.1016/S0038-092X(96)00115-6.
Park, S., M. Kim, J.-H. Lim, and S.-Y. Song. 2017. “Influence of drainage holes on condensation risk and air-tightness of windows an experimental case study of triple glazing PVC windows.” J. Asian Archit. Build. Eng. 16 (1): 83–90. https://doi.org/10.3130/jaabe.16.83.
Smith, N., N. Isaacs, J. Burgess, and I. Cox-Smith. 2012. “Thermal performance of secondary glazing as a retrofit alternative for single-glazed windows.” Energy Build. 54: 47–51. https://doi.org/10.1016/j.enbuild.2012.07.038.
Song, S.-Y. 1998. “A study on the method for determining the extent of insulation to prevent the inside surface condensation at thermal bridges.” J. Archit. Inst. Korea 14 (10): 275–284.
Song, S.-Y., J.-H. Jo, M.-S. Yeo, Y.-D. Kim, and K.-D. Song. 2007. “Evaluation of inside surface condensation in double glazing window system with insulation spacer: A case study of residential complex.” Build. Environ. 42 (2): 940–950. https://doi.org/10.1016/j.buildenv.2005.10.015.
Song, S.-Y., A.-R. Lim, J.-H. Song, J.-H. Lim, K.-N. Lee, and Y.-T. Kim. 2012. “Design criteria for preventing inside surface condensation on the curtain wall systems of office buildings.” J. Archit. Inst. Korea 28 (289): 383–392.
Song, S.-Y., S. Park, H.-H. Lee, H. Oh, and J.-H. Lim. 2016. Development of building technology to improve the living performance closely related with lifestyle to realize the housing welfare. Seoul, Korea: Ministry of Land, Infrastructure and Transport.
Zobec, M., M. Colombari, F. Peron, and P. Romagnoni. 2002. “Hot-box tests for building envelope condensation assessment. EPIC 2002 AIVC.” In Proc., 3rd European Conf. on Energy Performance Indoor Climate Buildings, 704–1035. Ghent, Belgium: Air Infiltration and Ventilation Centre.
Information & Authors
Information
Published In
Copyright
©2018 American Society of Civil Engineers.
History
Received: Aug 16, 2017
Accepted: Apr 12, 2018
Published online: Jul 24, 2018
Published in print: Oct 1, 2018
Discussion open until: Dec 24, 2018
Authors
Metrics & Citations
Metrics
Citations
Download citation
If you have the appropriate software installed, you can download article citation data to the citation manager of your choice. Simply select your manager software from the list below and click Download.