Effects of Postelastic Stiffness Ratio on Dynamic Increase Factor in Progressive Collapse
Publication: Journal of Performance of Constructed Facilities
Volume 31, Issue 6
Abstract
Prediction of structural response at the sudden removal of gravity load-bearing element in structures is an important issue in assessing progressive collapse potential of structures. In this paper, the effect of the postelastic stiffness ratio, as an effective parameter on the dynamic increase factor (DIF), in nonlinear static analysis of structures at the column removal is investigated, and a modified empirical DIF is presented. For this purpose, a series of low- and midrise moment frame structures with different span lengths and various numbers of stories are prepared, and the effect of the postelastic stiffness ratio on DIF is investigated, using several nonlinear static and dynamic analyses. For each postelastic stiffness ratio, a nonlinear dynamic analysis and a step-by-step nonlinear static analysis are carried out, and modified empirical DIF formulas are derived. Finally, an empirical formula is recommended that relates to the postelastic stiffness ratio. The new modified DIF can be used with a nonlinear static analysis instead of a nonlinear dynamic analysis to assess the progressive collapse potential of steel moment frame buildings having different postelastic stiffness ratios.
Get full access to this article
View all available purchase options and get full access to this article.
References
ASCE. (2010). “Minimum design loads for buildings and other structures.” ASCE/SEI 7-10, Reston, VA.
ASCE. (2013). “Seismic evaluation and retrofit of existing buildings.” ASCE/SEI 41-13, Reston, VA.
Baker, J. W., Schubert, M., and Faber, M. H. (2008). “On the assessment of robustness.” J. Struct. Saf., 30(3), 253–267.
Bennett, R. M. (1988). “Formulations for probability of progressive collapse.” J. Struct. Saf., 5(1), 67–77.
Brunesi, E., Nascimbene, R., and Parisi, F. (2016). “Progressive collapse fragility models of RC framed buildings based on pushdown analysis.” Proc., VII European Congress on Computational Methods in Applied Sciences and Engineering, National Technical Univ. of Athens, Athens, Greece.
Brunesi, E., Nascimbene, R., Parisi, F., and Augenti, N. (2015). “Progressive collapse fragility of reinforced concrete framed structures through incremental dynamic analysis.” Eng. Struct., 104, 65–79.
Cassiano, D., D’Aniello, M., Rebelo, C., Landolfo, R., and Silva, L. S. (2016). “Influence of seismic design rules on the robustness of steel moment resisting frames.” Steel Compos. Struct., 21(3), 479–500.
Chen, C. H., Zhu, Y. F., Yao, Y., and Huang, Y. (2016). “Progressive collapse analysis of steel frame structure based on the energy principle.” Steel Compos. Struct., 21(3), 553–571.
Ellingwood, B. R. (2006). “Mitigating risk from abnormal loads and progressive collapse.” J. Perform. Constr. Facil., 315–323.
FEMA. (2000). “State of the art report on systems performance of steel moment frames subject to earthquake ground shaking.” FEMA 355-C, Washington, DC.
GSA (General Services Administration). (2003). “Progressive collapse analysisand design guidelines for new federal office buildings andmajormodernization projects.” Washington, DC.
Izzuddin, B. A., Vlassis, A. G., Elghazouli, A. Y., and Nethercot, D. A. (2008). “Progressive collapse of multi-storey buildings due to sudden column loss. I: Simplified assessment framework.” Eng. Struct., 30(5), 1308–1318.
Liu, M. (2013). “A new dynamic increase factor for nonlinear static alternate path analysis of building frames against progressive collapse.” Eng. Struct., 48, 666–673.
Málaga-Chuquitaype, C., Elghazouli, A. Y., and Enache, R. (2016). “Contribution of secondary frames to the mitigation of collapse in steel buildings subjected to extreme loads.” Struct. Infrastruct. Eng., 12(1), 45–60.
Marjanishvili, S., and Agnew, E. (2006). “Comparison of various procedures for progressive collapse analysis.” J. Perform. Constr. Facil., 365–374.
Mashhadi, J., and Saffari, H. (2016). “Effects of damping ratio on dynamic increase factor in progressive collapse.” Steel Comps. Struct., 22(3), 677–690.
McKay, A. (2008). “Alternate path method in progressive collapse analysis: Variation of dynamic and non-linear load increase factors.” M.S. thesis, Univ. of Texas, San Antonio.
McKay, A., Marchand, K., and Diaz, M. (2012). “Alternate path method in progressive collapse analysis: Variation of dynamic and nonlinear load increase factors.” Pract. Period. Struct. Des. Constr., 152–160.
Mirtaheri, M., and Zoghi, M. (2016). “Design guides to resist progressive collapse for steel structures.” Steel Compos. Struct., 20(2), 357–378.
Ruth, P., Marchand, K. A., and Williamson, E. B. (2006). “Static equivalency in progressive collapse alternate path analysis: Reducing conservatism while retaining structural integrity.” J. Perform. Constr. Facil., 349–364.
SAP2000 version 14.2 [Computer software]. Computers and Structures, Berkeley, CA.
Song, B. I., Giriunas, K. A., and Sezen, H. (2014). “Progressive collapse testing and analysis of a steel frame building.” J. Constr. Steel Res., 94, 76–83.
Stevens, D. J., Crowder, B., Hall, B., and Marchand, K. (2008). “Unified progressive collapse design requirements for DoD and GSA.” Proc., Structures Congress, ASCE, Reston, VA.
Tsai, M. H., and Lin, B. H. (2009). “Dynamic amplification factor for progressive collapse resistance analysis of an RC building.” Struct. Des. Tall Special Build., 18(5), 539–557.
UFC-DoD (United Facilities Criteria-Department of Defense). (2013). “Design of buildings to resist progressive collapse.”, Washington, DC.
Information & Authors
Information
Published In
Copyright
©2017 American Society of Civil Engineers.
History
Received: Feb 15, 2017
Accepted: Jun 15, 2017
Published online: Oct 5, 2017
Published in print: Dec 1, 2017
Discussion open until: Mar 5, 2018
Authors
Metrics & Citations
Metrics
Citations
Download citation
If you have the appropriate software installed, you can download article citation data to the citation manager of your choice. Simply select your manager software from the list below and click Download.