IFC BIM-Based Facility Management Approach to Optimize Data Collection for Corrective Maintenance
Publication: Journal of Performance of Constructed Facilities
Volume 31, Issue 1
Abstract
Facility managers are required to collect high-quality data to achieve corrective maintenance actions. Current facility management (FM) information systems are complex and provide high-quality data. However, they lack interoperability and visualization capabilities. The goal of this study is to improve the quality of data collected that is required for corrective maintenance by utilizing visualization and interoperability capabilities of building information modeling (BIM). To achieve that, an approach that implements industry foundation classes (IFC) BIM to link and present alarms reported by FM systems, such as building energy management systems (BEMS) and building automation systems (BAS), with related data from computerized maintenance management systems (CMMS) was developed and validated on a typical university building. The results showed an efficiency increase in high-quality maintenance data collection. The proposed approach supplements the existing body of knowledge in the FM domain by providing a schema that integrates corrective maintenance data in a three-dimensional (3D) IFC-BIM environment. Moreover, it provides a process to minimize the corrective maintenance lead-time and link equipment failures to the related maintenance information. FM practitioners can use this approach to decrease the lead-time needed corrective maintenance responses and focus their resources on productive maintenance tasks.
Get full access to this article
View all available purchase options and get full access to this article.
References
Accruent LLC. (2015). 〈http://www.accruent.com/products/famis〉 (Apr. 17, 2015).
Agle, E., and Galbraith, S. (1991). Building air quality: A guide for building owners and facility managers, ERIC, Austin, TX.
Akcamete, A. (2011). “A formal approach for managing facility change information and capturing change history as part of building information models (BIMs).” Carnegie Mellon Univ., Pittsburgh.
Aljumaili, M., Tretten, P., Karim, R., and Kumar, U. (2012). “Study of aspects of data quality in e-maintenance.” Int. J. Condition Monitor. Diagn. Eng. Manage., 15(4), 3.
Al-Shalabi, F., and Turkan, Y. (2015). “A novel framework for BIM enabled facility energy management: A concept paper.” Int. Construction Specialty Conf. (ICSC 15), Univ. of British Columbia, Vancouver, BC, Canada.
Archibus. (2015). “Facilities and real estate applications for every challenge.” 〈http://www.archibus.com/Applications〉 (Oct. 13, 2015).
ASHRAE (2008). Systems and equipment, New York.
Aspurez, V., and Lewis, P. (2013). “Case study 3: USC school of cinematic arts.” BIM for facility managers, Wiley, New York, 185–232.
Azhar, S. (2011). “Building information modeling (BIM): Trends, benefits, risks, and challenges for the AEC industry.” Leadersh. Manage. Eng., 241–252.
Becerik-Gerber, B., Jazizadeh, F., Li, N., and Calis, G. (2012). “Application areas and data requirements for BIM-enabled facilities management.” J. Constr. Eng. Manage., 431–442.
BuildingSMART. (2013). “Industry foundation classes (IFC4).” 〈http://www.buildingsmart.com/bim〉.” (Nov. 20, 2015).
BuildingSMART. (2015). “COBIE.” http://www.nibs.org/?page=bsa_infoexchange.〉 (Oct. 15, 2015).
Chen, H.-M., Hou, C.-C., and Wang, Y.-H. (2013). “A 3D visualized expert system for maintenance and management of existing building facilities using reliability-based method.” Exp. Syst. Appl., 40(1), 287–299.
Dong, B., O’Neill, Z., and Li, Z. (2014). “A BIM-enabled information infrastructure for building energy fault detection and diagnostics.” Autom. Constr., 44, 197–211.
Doty, S., and Turner, W. C. (2009). Energy management handbook, Fairmont Press, Lilburn, GA.
Doty, S., and Turner, W. C. (2012). Energy management handbook, Fairmont Press, Lilburn, GA.
East, B., and Carrasquillo-Mangual, M. (2012). “The COBie guide.” 〈http://buildingsmartalliance.org/index.php/projects/cobieguide/〉 (Jan. 23, 2013).
East, E. W. (2007). “Construction operations building information exchange (COBie): Requirements definition and pilot implementation standard.” No. ERDC/CERL TR-07-30, Engineer Research and Development Center, Construction Engineering Research Lab, Champaign, IL.
Eastman, C., Teicholz, P., Sacks, R., and Liston, K. (2011). BIM handbook: A guide to building information modeling for owners, managers, designers, engineers and contractors, Wiley, Hoboken, NJ.
EcoDomus. (2013). “EcoDomus Portfolio.” 〈http://www.ecodomus.com/index.php/portfolio/clients/〉 (Mar. 16, 2015 ).
EcoDomus. (2015). “Digitizing the world’s capital assets.” 〈http://www.ecodomus.com/〉 (Oct. 13, 2015 ).
Fallon, K. K., and Palmer, M. E. (2007). NISTIR 7417 general buildings information handover guide: Principles, methodology and case studies an industry sector, National Institute of Standards and Technology (NIST), Gaithersburg, MD.
FM:Systems. (2015). 〈https://www.fmsystems.com/〉 (Oct. 13, 2015).
Gallaher, M., O’Connor, A., Dettbarn, J. Jr., and Gilday, L. (2004). “Cost analysis of inadequate interoperability in the US capital facilities industry.”, National Institute of Standards and Technology (NIST), Gaithersburg, MD.
Granderson, J., et al. (2011). “Energy information handbook: Applications for energy-efficient building operations.”, Lawrence Berkeley National Laboratory, Berkeley, CA.
Hu, Z., and Zhang, J. (2011). “BIM-and 4D-based integrated solution of analysis and management for conflicts and structural safety problems during construction: 2. Development and site trials.” Autom. Constr., 20(2), 167–180.
IFMA (International Facility Management Association). (2009). “Temperaturewars.” 〈http://www.ifma.org/docs/surveys/hvacsurvey2009.pdf?sfvrsn=2〉 (Nov. 25, 2015).
Jeong, S. K., and Ban, Y. U. (2011). “Computational algorithms to evaluate design solutions using space syntax.” Comput.-Aided Des., 43(6), 664–676.
Johnson-Controls. (2015). “Metasys.” 〈http://www.johnsoncontrols.com/content/us/en/products/building_efficiency/products-and-systems/building_management/metasys.html〉 (Sep. 9, 2015).
Jordani, D. A. (2010). “BIM and FM: The portal to lifecycle facility management.” J. Build. Inform. Model., 6, 13–16.
Kaiser, H. H., and Davis, J. S. (1996). A foundation to uphold: A study of facilities conditions at US colleges and universities, ERIC, Alexandria, VA.
Karim, R. (2008). “A service-oriented approach to e-maintenance of complex technical systems.” Division of Operation and Maintenance Engineering, Luleå Univ. of Technology, Luleå, Sweden.
Kelly, G., Serginson, M., Lockley, S., Dawood, N., and Kassem, M. (2013). “BIM for Facility management: A review and a case study investigating the value and challenges.” Proc., 13th Int. Conf. on Construction Applications of Virtual Reality, Teesside Univ., Middlesbrough, U.K.
Kensek, K. (2015). “BIM guidelines inform facilities management databases: A case study over time.” Buildings, 5(3), 899–916.
Khemlani, L. (2011). “BIM for facilities management.” 〈http://www.aecbytes.com/feature/2011/BIMforFM.html〉 (Oct. 13, 2015).
Kullolli, I. (2008). “Selecting a computerized maintenance management system.” Biomed. Instrum. Technol., 42(4), 276–278.
Kumar, U., Parida, A., Tretten, P., and Karim, R. (2014). “Enhancing the usability of maintenance data management systems.” J. Qual. Maintenance Eng., 20(3), 290–303.
Labib, A. W. (2004). “A decision analysis model for maintenance policy selection using a CMMS.” J. Qual. Maintenance Eng., 10(3), 191–202.
Laine, T., Hänninen, R., and Karola, A. (2007). “Benefits of BIM in the thermal performance management.” Proc., Building Simulation Conf., International Building Performance Simulation Association, Beijing.
Lee, S., and Akin, Ö. (2011). “Augmented reality-based computational fieldwork support for equipment operations and maintenance.” Autom. Constr., 20(4), 338–352.
Lin, Y.-C., and Su, Y.-C. (2013). “Developing mobile-and BIM-based integrated visual facility maintenance management system.” Sci. World J., 10.
Lin, Y.-C., Su, Y.-C., and Chen, Y.-P. (2012). “Mobile 2D barcode/bim-based facilities maintaining management system.” Int. Proc. Econ. Dev. Res., 43, 52–56.
Lin, Y.-H., Liu, Y.-S., Gao, G., Han, X.-G., Lai, C.-Y., and Gu, M. (2013). “The IFC-based path planning for 3D indoor spaces.” Adv. Eng. Inf., 27(2), 189–205.
Liu, X., Akinci, B., Garrett, J., and Bergés, M. (2011). “Requirements and development of a computerized approach for analyzing functional relationships among HVAC components using building information models.” Proc., CIB W78-W102, International Council for Building/International Council for Research and Innovation in Building and Construction (CIB), Delft, Netherlands.
Lucas, J., Bulbul, T., Thabet, W., and Anumba, C. (2013). “Case analysis to identify information links between facility management and healthcare delivery information in a hospital setting.” J. Archit. Eng., 134–145.
Markeset, T., and Kumar, U. (2003). “Design and development of product support and maintenance concepts for industrial systems.” J. Qual. Maintenance Eng., 9(4), 376–392.
McDowall, R. (2006). Fundamentals of HVAC systems, Academic Press, Atlanta.
Motamedi, A., Hammad, A., and Asen, Y. (2014). “Knowledge-assisted BIM-based visual analytics for failure root cause detection in facilities management.” Autom. Constr., 43, 73–83.
Motawa, I., and Almarshad, A. (2013). “A knowledge-based BIM system for building maintenance.” Autom. Constr., 29, 173–182.
Nisbet, N. (2008). “COBIE data import/export interoperability with the MAXIMO computerized maintenance management system.”, U.S. Army Corps of Engineers, Berkshire, U.K.
Nummelin, J., Sulankivi, K., Kiviniemi, M., and Koppinen, T. (2011). “Managing Building Information and client requirements in construction supply chain—Contractor’s view.” Proc., CIB W078-W102 Joint Conf., International Council for Building/International Council for Research and Innovation in Building and Construction (CIB), Delft, Netherlands.
Onuma. (2015). “Building informed environments.” 〈https://www.onuma.com〉 (Mar. 3, 2016).
Parsanezhad, P., and Dimyadi, J. (2014). “Effective facility management and operations via a BIM-based integrated information system.” Proc., Joint CIB W070, W111 & W118 Conf., Technical Univ. of Denmark, Copenhagen, 442–453.
Pietruschka, D., Biesinger, A., Trinkle, A., and Eicker, U. (2010). “Energy efficient operation of existing buildings through simulation based control optimisation.” Proc., IEECB, European Commission Joint Research Centre, Institute for Energy and Transport, Brussels, Belgium.
Qin, J., and Wang, S. (2005). “A fault detection and diagnosis strategy of VAV air-conditioning systems for improved energy and control performances.” Energy Build., 37(10), 1035–1048.
Roper, K. O., and Payant, R. P. (2014). The facility management handbook, AMACOM Division American Management Association, Broadway, New York.
Sallans, B., Bruckner, D., and Russ, G. (2006). “Statistical detection of alarm conditions in building automation systems.” Proc., 2006 IEEE Int. Conf. on Industrial Informatics, IEEE, Piscataway, NJ, 257–262.
Schein, J., Bushby, S. T., Castro, N. S., and House, J. M. (2006). “A rule-based fault detection method for air handling units.” Energy Build., 38(12), 1485–1492.
Tashakkori, H., Rajabifard, A., and Kalantari, M. (2015). “A new 3D indoor/outdoor spatial model for indoor emergency response facilitation.” Build. Environ., 89, 170–182.
Teicholz, P. (2013). BIM for facility managers, Wiley, Hoboken, NJ.
Tekla. (2013). “Tekla BIMsight.” 〈http://www.tekla.com/〉 (May. 1, 2015).
Tretten, P., Karim, R., and Kumar, U. (2011). “Usability-based eMaintenance for effective performance measurement.” Proc., Conf. on MPMM 2011: Maintenance Performance Measurement and Management, Luleå Tekniska Universitet, Luleå, 53–59.
Vanlande, R., Nicolle, C., and Cruz, C. (2008). “IFC and building lifecycle management.” Autom. Constr., 18(1), 70–78.
Wang, S., and Xiao, F. (2006). “Sensor fault detection and diagnosis of air-handling units using a condition-based adaptive statistical method.” HVAC&R Res., 12(1), 127–150.
Wang, Y., Wang, X., Wang, J., Yung, P., and Jun, G. (2013). “Engagement of facilities management in design stage through BIM: Framework and a case study.” Adv. Civ. Eng., 2013, 8.
William East, E., Nisbet, N., and Liebich, T. (2013). “Facility management handover model view.” J. Comput. Civ. Eng., 61–67.
Xiao, F. (2004). “Sensor fault detection and diagnosis of air handling units.” Ph.D. dissertation, Hong Kong Polytechnic Univ., Hong Kong.
Yang, X., and Ergan, S. (2015). “Leveraging BIM to provide automated support for efficient troubleshooting of HVAC-related problems.” J. Comput. Civ. Eng., 04015023.
Yao, R. (2013). Design and management of sustainable built environments, Springer, Berlin.
Zhang, J., and Hu, Z. (2011). “BIM-and 4D-based integrated solution of analysis and management for conflicts and structural safety problems during construction. 1: Principles and methodologies.” Autom. Constr., 20(2), 155–166.
Zhiliang, M., Zhenhua, W., Wu, S., and Zhe, L. (2011). “Application and extension of the IFC standard in construction cost estimating for tendering in China.” Autom. Constr., 20(2), 196–204.
Information & Authors
Information
Published In
Copyright
© 2016 American Society of Civil Engineers.
History
Received: Jan 22, 2016
Accepted: May 18, 2016
Published online: Jul 15, 2016
Discussion open until: Dec 15, 2016
Published in print: Feb 1, 2017
Authors
Metrics & Citations
Metrics
Citations
Download citation
If you have the appropriate software installed, you can download article citation data to the citation manager of your choice. Simply select your manager software from the list below and click Download.