Thermal Cracking of the Cylindrical Tank under Construction. I: Case Study
Publication: Journal of Performance of Constructed Facilities
Volume 29, Issue 4
Abstract
The authors present their own experimental studies, which include research on a reinforced-concrete cylindrical tank with a nominal unit capacity of , located in the sewage treatment plant in Krakow, Poland. The wall is monolithically connected to the foundation ring and was concreted in two stages: every second segment. This tank is classified among semimassive structures, which, owing to its volume and geometry, has an ability to store up a greater amount of released heat during the hardening process. At the stage of tank erection, because of cracks, numerous cases of leakage through the tank wall appeared. The measurement of longitudinal concrete deformation and crack development, together with the crack widths in selected segments, are presented. Moreover, the measurement of strains and crack-width propagation in vertical construction joints among three selected segments are discussed. The research presented provides information about the real behavior of such a structure under construction. In the subsequent paper (Part II), the results from experimental studies will be compared with the results obtained from an advanced numerical model.
Get full access to this article
View all available purchase options and get full access to this article.
References
Al Rawi, R. S., and Kheder, G. F. (1990). “Control of cracking due to volume change in base-restrained concrete members.” ACI Struct. J., 87(4), 397–405.
American Concrete Institute (ACI). (1990). “Cement and concrete terminology.” Detroit.
American Concrete Institute (ACI). (1992). “Prediction of creep, shrinkage and temperature effects in concrete structures.”, Detroit, 47.
American Concrete Institute (ACI). (2007). “Report on thermal and volume change effects on cracking of mass concrete.”, Detroit, 28.
Carlson, R. W., Donald, L. H., and Polivka, M. (1979). “Causes and control of cracking in unreinforced mass concrete.” ACI J. Proc., 76(7), 821–837.
Eberhardt, M., Lokhorst, S. J., and Breugel, K. V. (1994). “On the reliability of temperature differentials as a criterion for the risk of early-age thermal cracking.”, Münich, Germany, 353–360.
Emborg, M. (1989). “Thermal stresses in concrete structures at early ages.” Doctoral thesis, Division of Structural Engineering, Lulea Univ. of Technology, Lulea, Sweden, 280.
European Committee for Standardization (CEN). (2004). “Design of concrete structures—Part 1-1: General rules and rules for buildings.”, Brussels.
European Committee for Standardization (CEN). (2006). “PN-EN 1992–3. Design of concrete structures—Part 3: Liquid retaining and containment structures.”, Brussels.
European Committee for Standardization (CEN). (2012). “Cement—Part 1: Composition, specifications and conformity criteria for common cements.” EN 197-1, Brussels.
Ivanyi, G. (1995). “Bemerkungen zu Mindestbewehrung in Wänden.” Beton- und Stahlbetonbau, 90(11), 283–289.
Kheder, G. F., Ai-Rawi, R. S., and Ai-Dhahi, J. K. (1994). “A study behavior of volume change cracking in base restrained concrete walls.” Mater. Struct., 27(7), 383–392.
Lokhorst, S. J., and Van Breugel, K. (1995). “Prediction of thermal cracking in hardening concrete structures: Effects of various degrees of restraint.” FIP-CIA, Queensland Cement Limited, Brisbane, 273–280.
Nilsson, M. (2003). “Restraint factors and partial coefficients for crack risk analyses of early age concrete structures.” Doctoral thesis, Lulea Univ. of Technology, Lulea, Sweden, 170.
Paas, U. (1998). Mindestbewehrung für verformungsbehinderte Betonbauteile im jungen Alter, Deutscher Ausschuss für Stahlbeton, Berlin.
Pettersson, D., Alemo, J., and Thelandersson, S. (2002). “Influence on crack development in concrete structures from imposed strains and varying boundary conditions.” Constr. Build. Mater., 16(4), 207–213.
Pettersson, D., and Thelandersson, S. (2001). “Crack development in concrete structures due to imposed strains. Part I: Modelling.” Mater. Struct., 34(1), 7–13.
Rostásy, F. S., and Henning, W. (1989). “Zwang in Stahlbetonwänden auf Fundamenten.” Beton- und Stahlbetonbau, 84(8), 208–214.
Stoffers, H. (1978). Cracking due to shrinkage and temperature variation in walls, 3rd Ed., Delft Univ. of Technology and I.B.B.C., Delft, 68.
Tam, K. S. S., and Scanlon, A. (1986). “Analysis of cracking due to restrained volume change in reinforced concrete members.” J. Am. Concr. Inst., 83(4), 658–667.
Information & Authors
Information
Published In
Copyright
© 2014 American Society of Civil Engineers.
History
Received: Jul 4, 2013
Accepted: Jan 9, 2014
Published online: Jan 11, 2014
Discussion open until: Jan 26, 2015
Published in print: Aug 1, 2015
Authors
Metrics & Citations
Metrics
Citations
Download citation
If you have the appropriate software installed, you can download article citation data to the citation manager of your choice. Simply select your manager software from the list below and click Download.