Structural Aspects and Seismic Performance of 1-Story Precast Buildings in Turkey
Publication: Journal of Performance of Constructed Facilities
Volume 27, Issue 4
Abstract
A large-scale seismic performance assessment study based on 98 precast buildings, constructed in the high seismicity region of western Turkey, was performed. Structural properties of buildings were obtained from the design projects and then verified by site investigations. Statistical evaluations of inventory buildings have shown that stiffness and ductility capacity of existing buildings are insufficient. This situation indicates that structural deficiencies emphasized in recent earthquakes are not site specific, but wider and common. Seismic performance of precast buildings was estimated using two different demand spectrums and two different calculation methods. Demand spectrums were constructed by considering site-specific properties of the target region and properties of weak soil sites. Seismic performance of buildings was estimated using the capacity spectrum method and the equal displacement approach. Results of these methods indicate that damage distributions are significantly amplified by the weak soil properties. Distribution of building damages showed that the ratio of extensively damaged and collapsed buildings ranged from 20 to 80%, depending on the site amplification. A considerable amount of moderately damaged buildings implies that monetary losses may also be critical.
Get full access to this article
View all available purchase options and get full access to this article.
Acknowledgments
The research reported in this paper was supported by the Scientific and Technological Research Council of Turkey (TUBITAK) under Project No. 110M255 and the Turkish Precast Concrete Association. The authors also wish to express their gratitude to the directorate of the Denizli organized industrial zone for providing design projects of precast buildings.
References
Applied Technology Council. (1996). “Seismic evaluation and retrofit of concrete buildings.” ATC-40, Applied Technology Council, Redwood City, CA.
Arslan, M. H., Korkmaz, H. H., and Gulay, F. G. (2006). “Damage and failure pattern of prefabricated structures after major earthquakes in Turkey and shortfalls of the Turkish Earthquake Code.” Eng. Fail. Anal., 13(4), 537–557.
Atakoy, H. (2000). “The August 17th earthquake and the prefabricated structures built by the members of the prefabric union.” Concrete Prefabrication, 52–53(3), 5–14 (in Turkish).
Cruz, A. M., and Steinberg, L. J. (2005). “Industry preparedness for earthquakes and earthquake-triggered hazmat accidents in the 1999 Kocaeli Earthquake.” Earthq. Spectra, 21(2), 285–304.
Ersoy, U., and Ozcebe, G. (2001). Reinforced concrete, Evrim, Istanbul, Turkey (in Turkish).
Ersoy, U., Ozcebe, G., and Tankut, T. (2000). “Observed precast building damages in 1999 Marmara and Duzce Earthquakes.” Proc., 10th Prefabrication Symp., Turkish Precast Concrete Association, Anarka, Turkey, 1–10 (in Turkish).
Ersoy, U., Tankut, T., and Ozcebe, G. (1995). Earthquake behavior of precast building connections, Scientific and and Technological Research Council of Turkey, Ankara, Turkey (in Turkish).
European Committee for Standardization (CEN). (1998). “Design provisions for earthquake resistance of structures.” Eurocode 8, Brussels, Belgium.
Fabbrocino, G., Magliulo, G., Manfredi, G., and Cosenza, E. (2003). “Critical issues in seismic assessment of existing precast structures.” Proc., Concr. Struct. Seismic Regions, Fib-fédération Internationale du Béton, Athens, Greece.
FEMA. (2003). “NEHRP recommended provisions for seismic regulations of new buildings and other structures, Part 1: Provisions.” FEMA 450, National Institute of Building Sciences, Washington, DC.
Fischinger, M., Kramar, M., and Isakovic, T. (2008). “Cyclic response of slender RC columns typical of precast industrial buildings.” Bull. Earthq. Eng., 6(3), 519–534.
Freeman, S. A. (1998). “Development and use of capacity spectrum method.” Proc., 6th US National Conf. Earthq. Eng., Earthquake Engineering Research Institute (EERI), Oakland.
International Conference of Building Officials (ICBO). (1997). Uniform building code, Whittier, CA.
Karaesmen, E. (2001). Prefabrication in Turkey: Facts and figures. Dept. of Civil Engineering, Middle East Technical Univ., Ankara, Turkey.
Kılıncarslan, N., and Kılıncarslan, E. (2008). Geological and geotechnical investigation of Denizli organized industrial zone, Zemin Muhendislik, Denizli, Turkey (in Turkish).
Pacific Earthquake Engineering Research (PEER). (2005). “Pacific Earthquake Engineering Research Center: NGA Database.” 〈http://peer.berkeley.edu/nga/〉 (Sep. 17, 2011).
Palanci, M. (2010). “Seismic performance estimation of existing industrial precast structures based on building inventories.” M.S. thesis, Pamukkale Univ., Denizli, Turkey (in Turkish).
Park, R., and Paulay, T. (1975). Reinforced concrete structures, Wiley, New York.
Park, R., Priestley, M. J. N., and Gill, W. D. (1982). “Ductility of square-confined concrete columns.” J. Struct. Div., 108(4), 929–950.
Posada, M., and Wood, S. L. (2002). “Seismic performance of precast industrial buildings in Turkey.” Proc., 7th National Conf. Earthq. Eng., Earthquake Engineering Research Institute (EERI), Boston, 2285–2294.
Priestley, M. J. N., Calvi, M. C., and Kowalsky, M. J. (2007). Displacement based seismic design of structures, IUSS Press, Pavia, Italy.
Priestley, M. J. N., Seible, F., and Calvi, G. M. S. (1996). Seismic design and retrofit of bridges, Wiley, New York.
Saatcioglu, M., et al. (2001). “The August 17, 1999 Kocaeli (Turkey) Earthquake—Damage to structures.” Can. J. Civ. Eng., 28(4), 715–737.
Senel, S. M., and Kayhan, A. H. (2010). “Fragility based damage assessment in existing precast industrial buildings: A case study for Turkey.” J. Struct. Eng. Mech, 34(1), 39–60.
Sezen, H., and Whittaker, A. S. (2006). “Seismic performance of industrial facilities affected by the 1999 Turkey earthquake.” J. Perform. Constr. Facil., 20(1), 28–36.
Tezcan, S. S., and Colakoglu, H. K. (2003). “Weak points of the TEC-98 precast building code provisions.” Proc., 5th National Conf. Earthq. Eng., Istanbul Technical University Press, Istanbul, Turkey, 149–158 (in Turkish).
Turkish Earthquake Code (TEC). (1975). “Specifications for structures to be built in disaster areas.” TEC-1975, Ministry of Public Works and Settlement, Ankara, Turkey.
Turkish Earthquake Code (TEC). (1998). “Specifications for structures to be built in disaster areas.” TEC-1998, Ministry of Public Works and Settlement, Ankara, Turkey.
Turkish Earthquake Code (TEC). (2007). “Specifications for structures to be built in seismic areas.” TEC-2007, Ministry of Public Works and Settlement, Ankara, Turkey.
Zorbozan, M., Barka, G., and Sarifakioglu, F. (1998). “Observed precast building damages in Ceyhan Earthquake, reasons and solutions.” Concret. Prefabr., 12(48), 12–16 (in Turkish).
Information & Authors
Information
Published In
Copyright
© 2013 American Society of Civil Engineers.
History
Received: May 3, 2011
Accepted: Nov 22, 2011
Published online: Nov 24, 2011
Published in print: Aug 1, 2013
Authors
Metrics & Citations
Metrics
Citations
Download citation
If you have the appropriate software installed, you can download article citation data to the citation manager of your choice. Simply select your manager software from the list below and click Download.