Failure Analysis of Transmission Line Towers
Publication: Journal of Performance of Constructed Facilities
Volume 25, Issue 3
Abstract
Transmission line towers, though designed per code provisions, may fail during mandatory testing required in many countries. Different types of premature failures that were observed during full-scale testing of transmission line towers at Tower Testing and Research Station, Structural Engineering Research Centre, Chennai (CSIR-SERC) are studied, and the results are discussed in detail. The failures are modeled using finite-element software, and the analytical results and the test results are compared with various code provisions. The nonlinear finite-element analysis program NE-Nastran was used to model the elastoplastic behavior of towers. Bracing members with slenderness ratios above 170 become ineffective, even though they have to carry insignificant forces. Importance of design assumptions and connection detailing in overall performance of towers were studied. Nonlinear finite-element analysis is useful in understanding the system behavior and for prediction of the failure pattern and ultimate load. Based on the test results, the importance of studying these failures is highlighted and significant conclusions were drawn.
Get full access to this article
View all available purchase options and get full access to this article.
References
Albermani, F., and Kitipornchai, S. (2009). “Failure analysis of transmission towers.” Eng. Failure Anal., 16(6), 1922–1928.
ASCE. (2000). “Design of latticed steel transmission structures.” ASCE 10-97, Reston, VA.
British Standards Institution (BSI). (1999). “Lattice towers and masts: Part 3 code of practice for strength assessment of members of lattice towers and masts.” BS:8100-3:1999, London.
Bureau of Indian Standards (IS) (1978). “Code of practice for use of structural steel in over head transmission line towers—Testing.” IS:802 (Part III), New Delhi, India.
Bureau of Indian Standards (IS) (1992). “Code of practice for use of structural steel in over head transmission line towers—Permissible stresses.” IS:802 (Part 1/Sec 2), New Delhi, India.
Kemp, A. R., and Behncke, R. H. (1998). “Behavior of cross bracing in latticed towers.” J. Struct. Eng., 124(4), 360–367.
Lee, P. S., and McClure, G. (2007). “Elastoplastic large deformation analysis of a lattice steel tower structure and comparison with full scale tests.” J. Constr. Steel Res., 63, 709–717.
Rao, N. P., and Kalyanaraman, V. (2001). “Nonlinear behavior of lattice panel of angle tower.” J. Constr. Steel Res., 57, 1337–1357.
Structural Engineering Research Centre (CSIR-SERC). (1997). “800 kV S/C, ‘B30’ type tower.” Rep. No. 1030 41, Chennai, India.
Structural Engineering Research Centre (CSIR-SERC). (2000). “400 kV D/C type-DE (30–60°) dead end tower.” Rep. No. 1051 41, Chennai, India.
Structural Engineering Research Centre (CSIR-SERC). (2004). “220 kV M/C ‘PC-30’ type tower.” Rep. No. 1098 41, Chennai, India.
Information & Authors
Information
Published In
Copyright
© 2011 American Society of Civil Engineers.
History
Received: Feb 4, 2010
Accepted: Jul 27, 2010
Published online: Jul 31, 2010
Published in print: Jun 1, 2011
Authors
Metrics & Citations
Metrics
Citations
Download citation
If you have the appropriate software installed, you can download article citation data to the citation manager of your choice. Simply select your manager software from the list below and click Download.