Behavior of FRP-Steel Confined Concrete Tubular Columns Made of Expansive Self-Consolidating Concrete under Axial Compression
Publication: Journal of Composites for Construction
Volume 21, Issue 5
Abstract
A total of 32 fiber-reinforced polymer (FRP) confined concrete columns are manufactured and tested under axial compression including 8 FRP-confined solid columns (FCSCs), 4 FRP-confined concrete-filled steel tube columns (CCFTs), and 20 hybrid FRP-concrete-steel double-skin tubular columns (DSTCs). Key parameters include FRP layers, diameter of steel tube, and presence or absence of an expansive agent and concrete filling for the steel tube. Due to the effect of the expansive agent, prestress in concrete is detected in all specimens with expansive self-consolidating concrete (ESCC). For FCSCs and CCFTs, the normalized intercept, inflection and ultimate load for ESCC specimens are higher than those of self-consolidating concrete (SCC) specimens. For DSTCs, when the inner steel tube is filled with concrete only normalized ultimate loads are improved by in ESCC specimens compared with SCC specimens. For hollow DSTCs, however, an expansive agent does not improve the axial behavior. The number of layers of FRP show a positive influence on the normalized intercept, inflection, and ultimate load of ESCC FCSC specimens. In addition, test results for hollow DSTCs indicate that normalized ultimate loads decrease with the increase of steel tube diameter. An existing model used to predict the compressive strength and ultimate axial strain of FCSCs shows good agreement.
Get full access to this article
View all available purchase options and get full access to this article.
Acknowledgments
The financial support provided by National Natural Science Foundation of China under the Grant Nos. 51208077 and 51421064 is greatly appreciated.
References
Albitar, M., Ozbakkaloglu, T., and Louk Fanggi, B. A. (2015). “Behavior of FRP-HSC-steel double-skin tubular columns under cyclic axial compression.” J. Compos. Constr., 04014041.
ASTM. (2008). “Standard test method for tensile properties of polymer matrix composite materials.” ASTM D3039/3039M, West Conshohocken, PA.
ASTM. (2009). “Standard test method for slump flow of self-consolidating concrete.” ASTM C1611/C1611M, West Conshohocken, PA.
ASTM. (2014). “Standard test method for passing ability of self-consolidating concrete by J-ring.” ASTM C1621/C1621M, West Conshohocken, PA.
Campione, G., Mendola, L. L., Monaco, A., Valenza, A., and Flore, V. (2015). “Behavior in compression of concrete cylinders externally wrapped with basalt fibers.” Compos. Part B: Eng., 69, 576–586.
Cao, Q., and Ma, Z. J. (2011). “Behavior of externally fiber-reinforced polymer reinforced shrinkage-compensating concrete beams.” ACI Struct J., 108(5), 592–600.
Chabib, H. E., Nehdi, M., and Naggar, M. H. E. (2005). “Behavior of SCC confined in short GFRP tubes.” Cem. Concr. Compos, 27(1), 55–64.
Dai, J. G., Bai, Y. L., and Teng, J. G. (2011). “Behavior and modeling of concrete confined with FRP composites of large deformability.” J. Compos. Constr., 963–973.
Deng, Z. C., and Qu, J. L. (2015). “The experimental studies on behavior of ultrahigh-performance concrete confined by hybrid fiber-reinforced polymer tubes.” Adv. in Mater. Sci. and Eng., 1–18.
EFNARC (European Federation of National Associations Representing Concrete). (2005). “The European guidelines for self-compacting concrete.” European Federation of Specialist Construction Chemicals and Concrete Systems, Farnham, U.K.
Fam, A. Z., and Rizkalla, S. H. (2001). “Behavior of axially loaded concrete-filled circular fiber-reinforced polymer tubes.” ACI Struct J., 98(3), 280–289.
Fanggi, B. A. L., and Ozbakkaloglu, T. (2013). “Compressive behavior of aramid FRP-HSC-steel double-skin tubular columns.” Constr. Build. Mater., 48, 554–565.
Han, L. H., Tao, Z., Liao, F. Y., and Xu, Y. (2010). “Tests on cyclic performance of FRP–concrete–steel double-skin tubular columns.” Thin-Walled Struct., 48(6), 430–439.
Idris, Y., and Ozbakkaloglu, T. (2015). “Flexural behavior of FRP-HSC-steel double skin tubular beams under reversed-cyclic loading.” Thin-Walled Struct., 87, 89–101.
Lam, L., and Teng, J. G. (2003). “Design-oriented stress-strain model for FRP-confined concrete.” Constr. Build. Mater., 17(6–7), 471–489.
Mirmiran, A., and Shahawy, M. (1997). “Behavior of concrete columns confined by fiber composites.” J. Struct. Eng., 583–590.
Mortazavi, A. A., Pilakoutas, K., and Son, K. S. (2003). “RC column strengthening by lateral pre-tensioning of FRP.” Constr. Build. Mater., 17(6–7), 491–497.
Ozbakkaloglu, T., and Fanggi, B. L. (2014). “Axial compressive behavior of FRP-concrete-steel double-skin tubular columns made of normal- and high-strength concrete.” J. Compos. Constr., 04013027.
Ozbakkaloglu, T., and Idris, Y. (2014). “Seismic behavior of FRP-high strength concrete-steel double skin tubular columns.” J. Struct. Eng., 04014019.
Ozbakkaloglu, T., and Lim, J. C. (2013). “Axial compressive behavior of FRP-confined concrete: Experimental test data base and a new design-oriented model.” Compos. Part B: Eng., 55, 607–634.
Ozbakkaloglu, T., Lim, J. C., and Vincent, T. (2013). “FRP-confined concrete in circular sections: Review and assessment of stress-strain models.” Eng. Struct., 49, 1068–1088.
Ozbakkaloglu, T., and Vincent, T. (2014). “Axial compressive behavior of high-strength concrete-filled FRP tubes.” J. Compos. Constr., 04013037.
Rochette, P., and Labossiere, P. (2000). “Axial testing of rectangular column models confined with composites.” J. Compos. Constr, 129–136.
Samaan, M., Mirmiran, A., and Shahawy, M. (1998). “Model of concrete confined by fiber composites.” J. Struct. Eng., 1025–1031.
Teng, J. G., Huang, Y. L., Lam, L., and Ye, L. (2007a). “Theoretical model for fiber-reinforced polymer-confined concrete.” J. Compos. Constr., 201–210.
Teng, J. G., Jiang, T., Lam, L., and Luo, Y. Z. (2009). “Refinement of a design-oriented stress-strain model for FRP-confined concrete.” J. Compos. Constr., 269–278.
Teng, J. G., Yu, T., and Wong, Y. L. (2004). “Behaviour of hybrid FRP-concrete-steel double-skin tubular columns.” 2nd Int. Conf. on FRP Composites in Civil Engineering-CICE 2004, A. A. Balkema, Leiden, Netherlands, 811–818.
Teng, J. G., Yu, T., Wong, Y. L., and Dong, S. L. (2007b). “Hybrid FRP concrete-steel tubular columns: Concept and behavior.” Constr. Build. Mater., 21(4), 846–854.
Valdmanis, V., Lorenzis, L. D., Rousakis, T. C., and Tepfers, R. (2007). “Behaviour and capacity of CFRP-confined concrete cylinders subjected to monotonic and cyclic axial compressive load.” Struct. Concr., 8(4), 187–200.
Vincent, T., and Ozbakkaloglu, T. (2015). “Compressive behavior of prestressed high-strength concrete-filled aramid frp tube columns: Experimental observations.” J. Compos. Constr., 04015003.
Wang, R., Han, L. H., and Tao, Z. (2015). “Behavior of FRP-concrete–steel double skin tubular members under lateral impact: Experimental study.” Thin-Walled Struct., 95, 363–373.
Wong, Y. L., Yu, T., Teng, J. G., and Dong, S. L. (2008). “Behavior of FRP confined concrete in annular section columns.” Compos. Part B: Eng., 39(3), 451–466.
Xiao, Y., and Wu, H. (2000). “Compressive behavior of concrete confined by carbon fiber composite jackets.” J. Mater. Civ. Eng., 139–146.
Yan, Z., and Pantelides, C. P. (2011). “Concrete column shape modification with FRP shells and expansive cement concrete.” Constr. Build. Mater., 25(1), 396–405.
Yu, T., Fang, X. L., and Teng, J. G. (2014). “FRP-confined self-compacting concrete under axial compression.” J. Mater. Civ. Eng., 26(11), 1–8.
Yu, T., and Teng, J. G. (2013). “Behavior of hybrid FRP-concrete-steel double-skin tubular columns with a square outer tube and a circular inner tube subjected to axial compression.” J. Compos. Constr., 271–279.
Yu, T., Wong, Y. L., and Teng, J. G. (2010). “Behavior of hybrid FRP-concrete-steel double-skin tubular columns subjected to eccentric compression.” Adv. Struct. Eng., 13(5), 961–974.
Yu, T., Wong, Y. L., Teng, J. G., Dong, S. L., and Lam, E. S. (2006). “Flexural behaviour of hybrid FRP-concrete-steel double skin tubular members.” J. Compos. Constr., 443–452.
Yu, T., Zhang, B., Cao, Y. B., and Teng, J. G. (2012). “Behavior of hybrid FRP-concrete-steel double-skin tubular columns subjected to cyclic axial compression.” Thin-Walled Struct., 61, 196–203.
Information & Authors
Information
Published In
Copyright
©2017 American Society of Civil Engineers.
History
Received: Aug 16, 2016
Accepted: Feb 13, 2017
Published online: May 5, 2017
Published in print: Oct 1, 2017
Discussion open until: Oct 5, 2017
Authors
Metrics & Citations
Metrics
Citations
Download citation
If you have the appropriate software installed, you can download article citation data to the citation manager of your choice. Simply select your manager software from the list below and click Download.