Advanced Strategies and Materials for Reinforcing Normal and Disturbed Regions in Brick Masonry Columns
Publication: Journal of Composites for Construction
Volume 20, Issue 4
Abstract
This work presents the results of an experimental investigation on the behavior of 42 solid clay brick masonry columns internally strengthened by fiber-reinforced polymer (FRP) fabrics or stainless steel grids placed in horizontal mortar joints. In some cases, every course, and in other cases, alternate courses were reinforced with steel grids, carbon, and basalt FRP fabrics. Monotonic compressive loading tests were carried out under concentric and eccentric loads. Eccentric tests were carried out by loading the specimens on a reduced area with respect to the entire cross section, producing a disturbed region (D-region). A detailed characterization of the constituent materials was made experimentally. The compression tests show the effectiveness of the proposed strengthening techniques to produce increases in strength and the energy required for collapse of brick columns under concentric loads. Under eccentric loads, the reduction in the load-carrying capacity owing to the reduced loaded area is attenuated by the presence of the transverse reinforcements. An analytical expression is proposed that gives the strength of clay brick masonry columns considering that the biaxial strength domain of the bricks is modified because of the tensile contribution provided by the presence of transverse reinforcements. Moreover, a strut-and-tie model was utilized to calculate the load-carrying capacity in the D-region and was verified against experimental data, with good agreement.
Get full access to this article
View all available purchase options and get full access to this article.
References
Aiello, M., Micelli, F., and Valente, L. (2009). “FRP confinement of square masonry columns.” J. Compos. Constr., 148–158.
Amato, G., Campione, G., Cavaleri, L., Minafò, G., and Miraglia, N. (2012). “The use of pumice lightweight concrete for masonry applications.” Mater. Struct., 45(5), 679–693.
Borri, A., Castori, G., and Corradi, M. (2011). “Masonry confined by steel fiber-composite fibers.” Materials, 4(12), 311–326.
Brencich, A., Corradi, C., and Gambarotta, L. (2008). “Eccentrically loaded brickwork: Theoretical and experimental results.” Eng. Struct., 30(12), 3629–3643.
Campione, G., Granata, M. F., and Cucchiara, C. (2014). “Strengthening of solid brick masonry columns with joints collared by steel wires.” J. Civ. Eng. Sci., 3(3), 171–179.
Cavaleri, L., Failla, A., La Mendola, L., and Papia, M. (2005). “ Experimental and analytical response of masonry elements under eccentric vertical loads.” Eng. Struct., 27(8), 1175–1184.
Cavaleri, L., Fossetti, M., and Papia, M. (2009). “Modeling of out-of-plane behavior of masonry walls.” J. Struct. Eng., 1522–1532.
CEN (European Committee for Standardization). (2005). “Eurocode 6: Design of masonry structures. Part 1-1: General rules for reinforced and unreinforced masonry structures.” Brussels, Belgium.
Corradi, M., Borri, A., and Grazini, A. (2007). “Confinement of brick masonry columns with CFRP materials.” Compos. Sci. Technol., 67(9), 1772–1783.
Corradi, M., Borri, A., and Vignoli, A. (2002). “Strengthening techniques tested on masonry structures struck by the Umbria-Marche earthquake of 1997–1998.” Constr. Build. Mater., 16(4), 229–239.
Di Ludovico, M., D’Ambra, C., Prota, A., and Manfredi, G. (2010). “FRP confinement of tuff and clay brick columns: Experimental study and assessment of analytical models.” J. Compos. Constr., 583–596.
Ewing, B. D., and Kowalsky, M. J. (2004). “ Compressive behavior of unconfined and confined clay brick masonry.” J. Struct. Eng., 650–661.
Jurina, L. (2009). “Collapse tests on masonry externally wrapped.” Proc., IF CRASC 09, Univ. of Napoli “Federico II”, Napoli, Italy.
Köksal, H., Aktan, S., and Kuruşçu, A. (2012). “Elastoplastic finite-element analysis of FRP-confined masonry columns.” J. Compos. Constr., 407–417.
Krevaikas, T. D., and Triantafillou, T. C. (2005). “Masonry confinement with fiber-reinforced polymers.” J. Compos. Constr., 128–135.
Lignola, G. P., Angiuli, R., Prota, A., and Aiello, M. A. (2014). “FRP confinement of masonry: Analytical modeling.” Mater. Struct., 47(12), 2101–2115.
Malek, M. H. (1987). “Compressive strength of brickwork masonry with special reference to concentrated load.” Ph.D. thesis, Dept. of Civil Engineering, Building Science, Univ. of Edinburgh, Edinburgh, Scotland.
McNary, W. S., and Abrams, D. P. (1985). “Mechanics of masonry in compression.” J. Struct. Eng., 857–870.
Priestley, M. J. N., and Bridgeman, D. O. (1974). “Seismic resistance of brick masonry walls.” Bull. New Zealand Nat. Soc. Earthquake Eng., 7(4), 167–187.
Priestley, M. J. N., and Elder, D. M. (1983). “Stress-strain curves for unconfined and confined masonry.” ACI J., 80(3), 192–201.
Rao, K., and Pavan, G. (2015). “FRP-confined clay brick masonry assemblages under axial compression: Experimental and analytical investigations.” J. Compos. Constr., 04014068.
TestXpert v.7.11 [Computer software]. Zwick, Ulm, Germany.
Yin, P., Huang, L., Yan, L. B., and Zhu, D. J. (2015). “Compressive behavior of concrete confined by CFRP and transverse spiral reinforcement. Part A: Experimental study.” Mater. Struct., 1–11.
Information & Authors
Information
Published In
Copyright
© 2016 American Society of Civil Engineers.
History
Received: Jun 14, 2015
Accepted: Oct 22, 2015
Published online: Jan 21, 2016
Discussion open until: Jun 21, 2016
Published in print: Aug 1, 2016
Authors
Metrics & Citations
Metrics
Citations
Download citation
If you have the appropriate software installed, you can download article citation data to the citation manager of your choice. Simply select your manager software from the list below and click Download.