Residual Behavior of Shear-Repaired Concrete Beams Using CFRP Sheets Subjected to Elevated High Temperatures
Publication: Journal of Composites for Construction
Volume 16, Issue 3
Abstract
This paper presents the residual behavior of unreinforced concrete beams repaired with carbon fiber-reinforced polymer (CFRP) sheets in shear subjected to elevated temperatures up to 200°C. An experimental program is conducted to examine the effects of high-temperature exposure on the response of constitutive materials, adhesive–concrete interface, and shear repaired beams. All test beams are notched to represent various levels of shear deficiency. A predictive modeling approach is proposed based on classical laminate theory. Elevated temperatures influence the capacity and interfacial characteristics of the repaired beams. Temperature effects, however, are not significantly correlated with the formation of diagonal tension cracks (shear crack) and their propagation rate. Shear resistance of the CFRP is found to be independent of high-temperature exposure because of the load-resisting mechanism associated with crack-plane strains and shear-failure angle.
Get full access to this article
View all available purchase options and get full access to this article.
Acknowledgments
The writers gratefully acknowledge the support of North Dakota State University.
References
American Concrete Institute (ACI). (2008a). “Building code requirements for structural concrete and commentary.” ACI-318, Farmington Hills, MI.
American Concrete Institute (ACI). (2008b). “Guide for the design and construction of externally bonded FRP systems for strengthening concrete structures.” ACI-440.2R-08, Farmington Hills, MI.
ASTM. (2005). “Standard test method for tensile properties of polymer matrix composite materials.” ASTM 3039, West Conshohocken, PA.
Bakis, C. E., et al. (2002). “Fiber-reinforced polymer composites for construction-state-of-the-art review.” J. Compos. Constr., 6(2), 73–87.JCCOF2
BASF. (2007). “MBrace CF130 unidirectional high strength carbon fiber fabric for the MBrace composite strengthening system.” BASF Construction Chemicals, Shakopee, MN.
Bisby, L. A., Green, M. F., and Kodur, V. K. R. (2005a). “Modeling the behavior of fiber reinforced polymer-confined concrete columns exposed to fire.” J. Compos. Constr., 9(1), 15–24.JCCOF2
Bisby, L. A., Green, M. F., and Kodur, V. K. R. (2005b). “Response to fire of concrete structures that incorporate FRP.” Prog. Struct. Eng. Mater., 7(3), 136–149.
Cao, S. Y., Chen, J. F., Pan, J. W., and Sun, N. (2007). “ESPI measurement of bond–slip relationships of FRP–concrete interface.” J. Compos. Constr., 11(2), 149–160.JCCOF2
Cao, S., Wu, Z., and Wang, X. (2009). “Tensile properties of CFRP and hybrid FRP composites at elevated temperatures.” J. Compos. Mater.JCOMBI, 43(4), 315–330.
Chajes, M. J., Finch, W. W., Januszka, T. F., and Thomson, T. A. (1996). “Bond and force transfer of composite material plates bonded to concrete.” ACI Struct. J., 93(2), 208–217.ASTJEG
Chen, J. F., and Teng, J. G. (2003). “Shear capacity of FRP-strengthened RC beams: FRP debonding.” Constr. Build. Mater., 17(1), 27–41.
Choi, K.-K., Meshgin, P., and Taha, M. M. R. (2007). “Shear creep of epoxy at the concrete-FRP interfaces.” Composites, Part BCPBEFF, 38(5-6), 772–780.
Da Silva, L. F. M., and Adams, R. D. (2007). “Adhesive joints at high and low temperatures using similar and dissimilar adherends and dual adhesives.” Int. J. Adhes. Adhes., 27(3), 216–226.IJAADK
Degussa. (2006). “MBrace Saturant composite strengthening system resin.” Shanghai Master Builders Co. Ltd., Shanghai, China.
Foster, S. K., and Bisby, L. A. (2005). “High temperature residual properties of externally-bonded FRP systems.” ACI-SP230, American Concrete Institute, Farmington Hills, MI, 1235–1252.
Foster, S. K., and Bisby, L. A. (2008). “Fire survivability of externally bonded FRP strengthening systems.” J. Compos. Constr., 12(5), 553–561.JCCOF2
Gamage, J. C. P. H., Al-Mahaidi, R., and Wong, M. B. (2006). “Bond characteristics of CFRP plated concrete members under elevated temperatures.”Compos. Struct., 75(1-4), 199–205.COMSE2
Gamage, J. C. P. H., Wong, M. B., and Al-Mahaidi, R. (2005). “Performance of CFRP strengthened concrete members under elevated temperatures.” Proc., Int. Symp. on Bond Behaviour of FRP in Structures (BBFS 2005), Int. Institute for FRP in Construction, Winnipeg, MB, Canada, 113–118.
Green, M. F., Bisby, L. A., Beaudoin, Y., and Labossiere, P. (2000). “Effect of freeze–thaw cycles on the bond durability between fibre reinforced polymer plate reinforcement and concrete.” Can. J. Civ. Eng., 27(5), 949–959.CJCEB8
Green, M. F., Benichou, N., Kodur, V., and Bisby, L. A. (2007). “Design guidelines for fire resistance of FRP-strengthened concrete structures.” 8th Int. Conf. on Fiber Reinforced Polymer for Concrete Structures (FRPRCS-8) (CD-ROM), Patras, Greece.
Hognestad, E. (1951). “A study of combined bending and axial load in reinforced concrete members.” Bulletin 399, Univ. of Illinois Engineering Experiment Station, Urbana, IL.
Hyer, M. W. (1998). Stress analysis of fiber-reinforced composite materials, McGraw Hill, Boston.
Karbhari, V. M., et al. (2003). “Durability gap analysis for fiber-reinforced composites in civil infrastructure.” J. Compos. Constr., 7(3), 238–247.JCCOF2
Khoury, G. A. (2000). “Effect of fire on concrete and concrete structures.” Prog. Struct. Eng. Mater., 2(4), 429–447.
Kim, Y. J., Wight, R. G., and Green, M. F. (2008a). “Flexural strengthening of RC beams with prestressed CFRP sheets: development of non-metallic anchor systems.” J. Compos. Constr., 12(1), 35–43.JCCOF2
Kim, Y. J., Wight, R. G., and Green, M. F. (2008b). “Flexural strengthening of RC beams with prestressed CFRP sheets: Using nonmetallic anchor systems.” J. Compos. Constr., 12(1), 44–52.JCCOF2
Knaack, A. M., Kurama, Y. C., and Kirkner, D. J. (2009). “Stress–strain properties of concrete at elevated temperatures.” Structural Engineering Research Rep. NDSE-09-01, Univ. of Notre Dame, Notre Dame, IN.
Kodur, V. K. R., Bisby, L. A., and Green, M. F. (2007). “Guidance for the design of FRP-strengthened concrete members exposed to fire.” J. Fire Protect. Eng.JFPEEN, 17(5), 5–26.
Leone, M., Aiello, M. A., and Matthys, S. (2006). “The influence of service temperature on bond between FRP reinforcement and concrete.” Proc., 2nd FIB Congress (CD-ROM), FIB, EPFL, Lausanne, Switzerland.
Malek, A. M., and Saadatmanesh, H. (1998). “Ultimate shear capacity of reinforced concrete beams strengthened with web-bonded fiber-reinforced plastic.” ACI Struct. J., 95(4), 343–352ASTJEG.
Master Builders, Inc. (1998). MBrace TM composite strengthening system: Engineering design guidelines, 2nd Ed., Cleveland.
Matana, M., Nanni, A., Dharani, L., Silva, P., and Tunis, G. (2005). “Bond performance of steel reinforced polymer and steel reinforced grout.” Proc., Int. Symp. on Bond Behaviour of FRP in Structures (BBFS 2005) (CD-ROM), Int. Institute for FRP in Construction, Winnipeg, MB, Canada.
Nawy, E. G. (2008). Reinforced concrete: A fundamental approach, 6th Ed., Prentice Hall, Upper Saddle River, NJ.
Ren, H. T. (2003). “Study on basic theories and long time behavior of concrete structures strengthened by fiber reinforced polymers.” Ph.D. thesis, Dalian Univ. of Technology, Dalian City, China.
Saafi, M. (2002). “Effect of fire on FRP reinforced concrete members.” Compos. Struct., 58(1), 11–20.COMSE2
Shaat, A., and Fam, A. (2008). “Repair of cracked steel girders connected to concrete slabs using carbon-fiber-reinforced polymer sheets.” J. Compos. Constr., 12(6), 650–659.JCCOF2
Tan, Z. (2002). “Experimental research for RC beams strengthened with GFRP.” Master’s thesis, Tsinghua Univ., Beijing.
Teng, J. G., Chen, J. F., Smith, T., and Lam, L. (2002). FRP-strengthened RC structures, Wiley, West Sussex, UK.
Teng, J. G., Chen, J. F., Smith, T., and Lam, L. (2003). “Behavior and strength of FRP-strengthened RC structures: A state-of-the-art review.” Proc., ICE, Struct. Build.SDTBEH, 156(1), 51–62.
Triantafillou, T. C. (1998). “Shear strengthening of reinforced concrete beams using epoxy-bonded FRP composites.” ACI Struct. J., 95(2), 107–115.ASTJEG
Williams, B. K., Bisby, L., Kodur, K., Green, M., and Chowdhury, E. (2006). “Fire insulation schemes for FRP-strengthened concrete slabs.” Composites Part ACASMFJ, 37(8), 1151–1160.
Yao, J., Teng, J. G., and Chen, J. F. (2005). “Experimental study on FRP-to-concrete bonded joints.” Composites Part BCPBEFF, 36(2), 99–113.
Youssef, M. A., and Moftah, M. (2007). “General stress-strain relationship for concrete at elevated temperatures.” Eng. Struct., 29(10), 2618–2634.ENSTDF
Zhao, H. D., Zhang, Y., and Zhao, M. (2000). “Research on the bond performance between CFRP plate and concrete.” Proc., 1st Conf. on FRP–Concrete Structures of China, 247–253.
Information & Authors
Information
Published In
Copyright
© 2012. American Society of Civil Engineers.
History
Received: Feb 17, 2011
Accepted: Aug 1, 2011
Published online: Aug 3, 2011
Published in print: Jun 1, 2012
Authors
Metrics & Citations
Metrics
Citations
Download citation
If you have the appropriate software installed, you can download article citation data to the citation manager of your choice. Simply select your manager software from the list below and click Download.