TECHNICAL PAPERS
Dec 16, 2010

Testing and Modeling of a New Moment Connection of Concrete-Filled FRP Tubes to Footings under Monotonic and Cyclic Loadings

Publication: Journal of Composites for Construction
Volume 15, Issue 4

Abstract

This study explores a new moment connection of concrete-filled fiber-reinforced polymer (FRP) tube (CFFT) to concrete footing. The tube is tightly fitted and adhesively bonded to a short reinforced concrete stub protruding from the footing, which facilitates concrete filling of the tube without the need for shoring. To establish the critical stub length (Xcr), specimens with heavily steel-reinforced stubs varying in length from 0.5D to 2.0D, where D = diameter of the CFFT, were fabricated and tested in flexure by using a cantilever setup. The Xcr required to achieve flexural failure of the CFFT was 1.05D. Additional specimens with a sufficient stub length of 1.5D were then fabricated to examine the effect on strength and ductility of the steel reinforcement ratio (ρs) in the stub. The optimal ρs of the stub required for the CFFT to reach flexural failure was 3.2%. Finally, the effect of low-cycle reversed bending fatigue was studied with and without an axial compression load. Remarkable ductility associated with the formation of a plastic hinge was observed at ρs of 2%. An analytical model capable of predicting (1) moment capacity of the connection, (2) whether failure is governed by flexure or bond, and (3) Xcr was developed and validated. It was then used in a parametric study to explore the effects of CFFT mechanical and geometric properties on Xcr.

Get full access to this article

View all available purchase options and get full access to this article.

Acknowledgments

The authors wish to acknowledge the Natural Sciences Engineering Research Council of Canada (NSERC), the Canada Research Chairs program, the Early Researcher’s Award Program and MRI Postdoctoral Fellowship of the Ontario Government, and Queen’s University for the Chancellor’s Research Award. The authors are also grateful to Paul Thrasher and David Tryon from Queen’s University.

References

Fam, A. Z. (2000). “Concrete-filled fibre reinforced polymer tubes for axial and flexural structural members.” Ph.D. thesis, Dept. of Civil Engineering, Univ. of Manitoba, Winnipeg, Canada.
Fam, A., Flisak, B., and Rizkalla, S. (2003a). “Experimental and analytical modeling of concrete-filled fiber-reinforced polymer tubes subjected to combined bending and axial loads.” ACI Struct. J., 100(4), 499–509.
Fam, A., Greene, R., and Rizkalla, S. (2003b). “Field applications of concrete-filled FRP tubes for marine piles.” Field application of FRP reinforcement: Case studies, SP-215-9:161-180, American Concrete Institute, Detroit.
Fam, A., Pando, M., Filz, G., and Rizkalla, S. (2003c). “Precast piles for Route 40 bridge in Virginia using concrete filled FRP tubes.” PCI J., 48(3), 32–45.
Fam, A. Z., and Rizkalla, S. H. (2002). “Flexural behavior of concrete-filled fiber-reinforced polymer circular tubes.” J. Compos. Constr., 6(2), 123–132.
Fam, A., and Son, J. K. (2008). “Finite element modeling of hollow and concrete-filled fiber composite tubes in flexure: Optimization of partial filling and a design method for poles.” Eng. Struct., 30(10), 2667–2676.
Lai, Y. C. (2010). “Moment connections of concrete-filled fibre reinforced polymer tubes to reinforced concrete footings.” M.Sc. thesis, Queen’s Univ., Kingston, Ontario, Canada.
Mirmiran, A., and Shahawy, M. (1997). “Behavior of concrete columns confined by fiber composites.” J. Struct. Eng., 123(5), 583–590.
Nelson, M., Lai, Y. C., and Fam, A. (2008). “Moment connection of concrete-filled fiber reinforced polymer tubes by direct embedment into footings.” Adv. Struct. Eng., 11(5), 537–547.
Qasrawi, Y., and Fam, A. (2008). “Flexural load tests on new spun-cast concrete-filled fiber-reinforced polymer tubular poles.” ACI Struct. J., 105(6), 750–759.
Sadeghian, P., and Fam, A. (2010). “Bond-slip analytical formulation towards optimal embedment of concrete-filled circular FRP tubes into concrete footings.” J. Eng. Mech., 136(4), 524–533.
Sadeghian, P., and Fam, A. (2011). “Closed-form model and parametric study on connection of concrete-filled FRP tubes into concrete footings by direct embedment.” J. Eng. Mech., 137(5), 346–354.
Vecchio, F. J., and Collins, M. P. (1986). “The modified compression-field theory for reinforced concrete elements subjected to shear.” J. Am. Concr. Inst., 83(2), 219–231.
Zhu, Z., Ahmad, I., and Mirmiran, A. (2006). “Seismic performance of concrete-filled FRP tube columns for bridge substructure.” J. Bridge Eng., 11(3), 359–370.
Zhu, Z., Mirmiran, A., and Shahawy, M. (2004). “Stay-in-place fiber reinforced polymer forms for precast modular bridge pier system.” J. Compos. Constr., 8(6), 560–568.

Information & Authors

Information

Published In

Go to Journal of Composites for Construction
Journal of Composites for Construction
Volume 15Issue 4August 2011
Pages: 653 - 662

History

Received: Aug 22, 2010
Accepted: Dec 14, 2010
Published online: Dec 16, 2010
Published in print: Aug 1, 2011

Permissions

Request permissions for this article.

Authors

Affiliations

Pedram Sadeghian, M.ASCE [email protected]
Postdoctoral Fellow, Dept. of Civil Engineering, Queen’s Univ., Kingston, ON, K7L 3N6 Canada. E-mail: [email protected]
Yu Ching Lai [email protected]
Formerly, Master’s Student, Dept. of Civil Engineering, Queen’s Univ., Kingston, ON, K7L 3N6 Canada. E-mail: [email protected]
Amir Fam, M.ASCE [email protected]
Professor and Canada Research Chair in Innovative and Retrofitted Structures, Dept. of Civil Engineering, Queen’s Univ., Kingston, ON, K7L 3N6 Canada (corresponding author). E-mail: [email protected]

Metrics & Citations

Metrics

Citations

Download citation

If you have the appropriate software installed, you can download article citation data to the citation manager of your choice. Simply select your manager software from the list below and click Download.

Cited by

View Options

Get Access

Access content

Please select your options to get access

Log in/Register Log in via your institution (Shibboleth)
ASCE Members: Please log in to see member pricing

Purchase

Save for later Information on ASCE Library Cards
ASCE Library Cards let you download journal articles, proceedings papers, and available book chapters across the entire ASCE Library platform. ASCE Library Cards remain active for 24 months or until all downloads are used. Note: This content will be debited as one download at time of checkout.

Terms of Use: ASCE Library Cards are for individual, personal use only. Reselling, republishing, or forwarding the materials to libraries or reading rooms is prohibited.
ASCE Library Card (5 downloads)
$105.00
Add to cart
ASCE Library Card (20 downloads)
$280.00
Add to cart
Buy Single Article
$35.00
Add to cart

Get Access

Access content

Please select your options to get access

Log in/Register Log in via your institution (Shibboleth)
ASCE Members: Please log in to see member pricing

Purchase

Save for later Information on ASCE Library Cards
ASCE Library Cards let you download journal articles, proceedings papers, and available book chapters across the entire ASCE Library platform. ASCE Library Cards remain active for 24 months or until all downloads are used. Note: This content will be debited as one download at time of checkout.

Terms of Use: ASCE Library Cards are for individual, personal use only. Reselling, republishing, or forwarding the materials to libraries or reading rooms is prohibited.
ASCE Library Card (5 downloads)
$105.00
Add to cart
ASCE Library Card (20 downloads)
$280.00
Add to cart
Buy Single Article
$35.00
Add to cart

Media

Figures

Other

Tables

Share

Share

Copy the content Link

Share with email

Email a colleague

Share