Development of Mechanical Anchor for CFRP Tendons Using Integrated Sleeve
Publication: Journal of Composites for Construction
Volume 14, Issue 4
Abstract
A durable and very efficient external strengthening system is achieved if steel tendons for posttensioning applications can be replaced with carbon fiber-reinforced polymer (CFRP) tendons, and if reliable anchorage systems are developed. This paper presents a newly developed and simple-to-use, two-piece wedge anchorage for CFRP tendons with an integrated sleeve and a differential angle between barrel and wedge sections. Three longitudinal slits are cut into the one-piece wedge, with one slit open and the other two stopping 1 mm from the inner wedge hole. The integrated sleeve holds the wedge’s sections together during presetting and loading, resulting in a circumferential confined gripping of the CFRP tendon and optimized surface friction area. Therefore, the one-piece wedge differs from conventional wedge systems, where the wedges act separately with adjacent spaces, wedging the separate tendon sleeve in the longitudinal direction. Evaluation of the failure modes during testing was one of the main keys in achieving an increasingly better performance of the anchorage until the final anchorage was developed. The obtained failure modes are therefore described to enlighten the importance of addressing them when testing. The test setup used and measured behavior are described further together with the loading procedure. The anchorage reached the full capacity of the CFRP tendon and was seen to ensure a stable load of fracture.
Get full access to this article
View all available purchase options and get full access to this article.
Acknowledgments
The writers of this paper would like to express their appreciation for the financial support given by the Development Fund of the Swedish Construction Industry (SBUF) together with Skanska AB and COWI A/S. Furthermore, thanks to Guðjón Magnússon and Finnur Gíslason who have done a great job carrying out the experiments in cooperation with the writers of this paper.
References
Al-Mayah, A., Soudki, K., and Plumtree, A. (2005). “Effect of sandblasting on interfacial contact behavior of carbon-fiber-reinforced polymer-metal couples.” J. Compos. Constr., 9(4), 289–295.
Al-Mayah, A., Soudki, K., and Plumtree, A. (2006a). “Development and assessment of a new CFRP rod-anchor system for prestressed concrete.” Appl. Compos. Mater., 13, 321–334.
Al-Mayah, A., Soudki, K., and Plumtree, A. (2006b). “Effect of sleeve material on interfacial contact behavior of CFRP-metal couples.” J. Mater. Civ. Eng., 18(6), 825–830.
Al-Mayah, A., Soudki, K., and Plumtree, A. (2007). “Novel anchor system for CFRP rod: finite-element and mathematical models.” J. Compos. Constr., 11(5), 469–476.
Al-Mayah, A., Soudki, K., and Plumtree, A. (2008). “Effect of rod profile and strength on the contact behavior of CFRP-metal couples.” Compos. Struct., 82, 19–27.
American Concrete Institute (ACI). (2001). “Specification for unbonded single-strand tendons and commentary.” ACI 423.6-01, Farmington Hills, Mich.
Benmokrane, B., Xu, H., and Nishizaki, I. (1997). “Aramid and carbon fibre-reinforced plastic prestressed ground anchors and their field applications.” Can. J. Civ. Eng., 24, 968–985.
Benmokrane, B., Zhang, B., and Chennouf, A. (2000). “Tensile properties and pullout behaviour of AFRP and CFRP rods for grouted anchor applications.” Constr. Build. Mater., 14, 157–170.
Burtscher, S. L. (2006). “Wedge anchorage for loaded or prestressed FRP.” Proc., 3rd Int. Conf. on FRP Composites in Civil Engineering, IIFC, Miami, 483–486.
Czaderski, C., and Motavalli, M. (2007). “40-year-old full-scale concrete bridge girder strengthened with prestressed CFRP plates anchored using gradient method.” Composites, Part B, 38, 878–886.
El-Hacha, R., Green, M., and Wight, G. (2000). “Strengthening of concrete members with prestressed FRP sheets: Behaviour at room and low temperature.” Proc., Annual Conf. of the Canadian Society for Civil Engineering, CSCE, Montréal, 737–749.
El-Hacha, R., Green, M. F., and Wight, R. G. (2004a). “Flexural behaviour of concrete beams strengthened with prestressed carbon fibre reinforced polymer sheets subjected to sustained loading and low temperature.” Can. J. Civ. Eng., 31(2), 239–252.
El-Hacha, R., Wight, R. G., and Green, M. F. (2003). “Innovative system for prestressing fiber-reinforced polymer sheets.” ACI Struct. J., 100(3), 305–313.
El-Hacha, R., Wight, R. G., and Green, M. F. (2004b). “Prestressed carbon fiber reinforced polymer sheets for strengthening concrete beams at room and low temperatures.” J. Compos. Constr., 8(1), 3–13.
El-Hacha, R., Wright, G., and Green, M. F. (1999). “Anchors for prestressing FRP sheets.” Proc., Annual Conf. of the Canadian Society for Civil Engineering, CSCE, Regina, Canada, 235–244.
Enka, B. (1986). “Arapree—The Twaron resin prestressing element for concrete.” Corporate Rep., Arnhem, The Netherlands.
European Organisation for Technical Approval (EOTA). (2002). Guideline for European technical approval of post-tensioning kits for prestressing of structures, Brussels, Belgium.
Lees, J. M., Gruffydd-Jones, B., and Burgoyne, C. J. (1995). “Expansive cement couplers: A means of pretensioning fibre-reinforced plastic tendons.” Constr. Build. Mater., 9(6), 413–423.
Marceau, D., Fafard, M., and Bastien, J. (2003). “Constitutive law for wedge-tendon gripping interface in anchorage device—Numerical modelling and parameters identification.” Struct. Eng. Mech., 15(6), 609–628.
Monti, G., and Liotta, M. A. (2007). “Pretensioning of externally bonded FRP fabrics for flexural reinforcement of RC Beams: Method and design equations” Asia-Pacific Conf. on FRP in Structures, APFIS, Hong Kong, 379–392.
Nanni, A., Bakis, E. C., Edward, F. O., Dixon, T. O. (1996). “Performance of FRP tendon-anchor systems for prestressed concrete structures.” PCI J., 34–44.
Noisternig, J. E., and Jungwirth, D. (1996). “Design and analysis of anchoring systems for a carbon fiber composite cable.” Proc., Advanced Composite Materials in Bridges and Structures, CSCE, Montréal, 935–942.
Nordin, H., and Taljsten, B. (2006). “Concrete beams strengthened with prestressed near surface mounted CFRP.” J. Compos. Constr., 10(1), 60–68.
Post-Tensioning Institute (PTI). (1998). Acceptance standards for post-tensioning systems, 1st Ed., Phoenix.
Post-Tensioning Institute (PTI). (2006). Post-tensioning manual, 6th Ed., Phoenix.
Reda Taha, M. M., and Shrive, N. G. (2003). “New concrete anchors for carbon fiber-reinforced polymer post-tensioning tendons—Part 2: Development/experimental investigation.” ACI Struct. J., 100(1), 96–104.
Rostásy, F. S. (1998). “Draft guidelines for the acceptance testing of FRP post-tensioning tendons.” J. Compos. Constr., 2(1), 2–6.
Said, H., and Wu, Z. (2008). “Evaluating and proposing models of predicting IC debonding failure.” J. Compos. Constr., 12(3), 284–299.
Sayed-Ahmed, E. Y. (2002). “Single- and multi-strand steel anchorage systems for CFRP tendons/stays.” Proc., Structural Speciality Conf., CSCE, Montréal, 1381–1390.
Sayed-Ahmed, E. Y., and Shrive, N. G. (1998). “New steel anchorage system for post-tensioning applications using carbon fibre reinforced plastic tendons.” Can. J. Civ. Eng., 25(1), 113–127.
Schön, J. (2004a). “Coefficient of friction for aluminum in contact with a carbon fiber epoxy composite.” Tribol. Int., 37(5), 395–404.
Schön, J. (2004b). “Coefficient of friction and wear of a carbon fiber epoxy matrix composite.” Wear, 257(3-4), 395–407.
Stöcklin, I., and Meier, U. (2001). “Strengthening of concrete structures with pre-stressed gradually anchored CFRP strips.” Proc., Fiber-Reinforced Polymer Reinforcement for Concrete Structures, FRPRCS-R Conference, Cambridge, U.K., 291–296.
Täljsten, B. (1997). “Strengthening of beams by plate bonding.” J. Mater. Civ. Eng., 9(4), 206–212.
Wu, Z. (2007). “Integrated strengthening of structures with bonded pre-stressed FRP reinforcement.” Proc., Fiber Reinforced Polymers in Structures, Asia-Pacific Conference on FRP in Structures—APFIS, Hong Kong, 43–52.
Zhang, B., Benmokrane, B., Chennouf, A., Mukhopadhyaya, P., and El-Safty, A. (2001). “Tensile behavior of FRP tendons for prestressed ground anchors.” J. Compos. Constr., 5(2), 85–93.
Information & Authors
Information
Published In
Copyright
© 2010 ASCE.
History
Received: Jun 2, 2009
Accepted: Dec 3, 2009
Published online: Feb 3, 2010
Published in print: Aug 2010
Authors
Metrics & Citations
Metrics
Citations
Download citation
If you have the appropriate software installed, you can download article citation data to the citation manager of your choice. Simply select your manager software from the list below and click Download.