Outdoor Test of a Prefabricated Column–Pile Cap–Pile System under Combined Vertical and Lateral Loads
Publication: Journal of Bridge Engineering
Volume 25, Issue 8
Abstract
An outdoor test was conducted on a prefabricated column–pile cap–pile system at a cohesive soil site. The half-scale test unit consisted of a precast bridge column, a precast pile cap, and eight steel piles. The components were connected utilizing socket connections that were preformed in the pile cap with corrugated steel pipes. To evaluate the system performance and the behavior of various connections, the test unit was subjected to combined vertical and lateral loads at service conditions as well as at conditions representing extreme events. The test unit remained undamaged under the loads representing the service conditions, and a plastic hinge was formed in the column under loading conditions representing a seismic event. The column connection and pile connections exhibited excellent behavior as they maintained fixity with the formation of a column plastic hinge. The outdoor test demonstrated that up to 40% of column top displacement was produced by foundation flexibility at the service conditions. The description of the outdoor test and key results are included in this paper.
Get full access to this article
View all available purchase options and get full access to this article.
Acknowledgments
This study was supported by the Iowa Highway Research Board (IHRB) and the Federal Highway Administration State Transportation Innovation Council (STIC). The authors would like to thank the members of the Technical Advisory Committee for their advice and suggestions.
References
AASHTO. 2016. Standard specification for steel sheet, zinc-coated (galvanized), for corrugated steel pipe. Rep. No. AASHTO M-218. Washington, DC: AASHTO.
AASHTO. 2017. LRFD bridge design specifications. 8th ed. Washington, DC: AASHTO.
Ameli, M. J., and C. P. Pantelides. 2017. “Seismic analysis of precast concrete bridge columns connected with grouted splice sleeve connectors.” J. Struct. Eng. 143 (2): 04016176. https://doi.org/10.1061/(ASCE)ST.1943-541X.0001678.
ASTM. 2014. Standard test methods and definitions for mechanical testing of steel products. ASTM A370/A370M-14. West Conshohocken, PA: ASTM.
ASTM. 2015. Standard specification for structural steel for bridges. ASTM A709/A709M-15. West Conshohocken, PA: ASTM.
ASTM. 2016. Standard test method for compressive strength of hydraulic cement mortars (using 2-in. or [50-mm] cube specimens). ASTM C109/C109M-16a. West Conshohocken, PA: ASTM.
ASTM. 2018. Standard test method for compressive strength of cylindrical concrete specimens. ASTM C39/C39M-18. West Conshohocken, PA: ASTM.
Cheng, Z., and S. Sritharan. 2019. “Side shear strength of preformed socket connections suitable for vertical precast members.” J. Bridge Eng. 24 (5): 04019025. https://doi.org/10.1061/(ASCE)BE.1943-5592.0001391.
Culmo, M. P. 2009. Connections details for prefabricated bridge elements and systems. Rep. No. FHWA-IF-09-010. Washington, DC: FHWA.
Culmo, M. P. 2011. Accelerated bridge construction—Experiences in design, fabrication and erection of prefabricated bridge elements and systems. Rep. No. FHWA-HIF-12-013. Washington, DC: FHWA.
Haber, Z. B., M. S. Saiidi, and D. H. Sanders. 2014. “Seismic performance of precast columns with mechanically spliced column-footing connections.” ACI Struct. J. 111 (3): 639–650. https://doi.org/10.14359/51686624.
Haraldsson, O. S., T. M. Janes, M. O. Eberhard, and J. F. Stanton. 2013. “Seismic resistance of socket connection between footing and precast column.” J. Bridge Eng. 18 (9): 910–919. https://doi.org/10.1061/(ASCE)BE.1943-5592.0000413.
Iowa DOT (Iowa Department of Transporatation). 2018. LRFD bridge design manual. Ames, IA: Iowa DOT.
Kavianipour, F., and M. S. Saiidi. 2013. Experimental and analytical seismic studies of a four-span bridge system with composite piers. CCEER-13-17. Reno, NV: Univ. of Nevada.
Marsh, L. M., M. Wernli, B. E. Garrett, J. F. Stanton, M. O. Eberhard, and M. D. Weinert. 2011. Application of accelerated bridge construction connections in moderate-to-high seismic regions. Rep. No. 698. Washington, DC: NCHRP.
Mehrsoroush, A., and M. S. Saiidi. 2016. “Cyclic response of precast bridge piers with novel column-base pipe pins and pocket cap beam connections.” J. Bridge Eng. 21 (4): 04015080. https://doi.org/10.1061/(ASCE)BE.1943-5592.0000833.
Mohebbi, A., M. S. Saiidi, and A. Itani. 2017. Development and seismic evaluation of pier system w/pocket connections, CFRP tendons, and ECC/UHPC columns. CCEER-17-02. Reno, NV: Univ. of Nevada.
Motaref, S., M. S. Saiidi, and D. Sanders. 2011. Seismic response of precast bridge columns with energy dissipating joints. CCEER-11-01. Reno, NV: Univ. of Nevada.
Priestley, M. J. N., F. Seible, and G. M. Calvi. 1996. Seismic design and retrofit of bridges. New York: John Wiley & Sons.
Restrepo, J. I., M. J. Tobolski, and E. E. Matsumoto. 2011. Development of a precast bent cap system for seismic regions. Rep. No. 681. Washington, DC: NCHRP.
Shafieifar, M., M. Farzad, and A. Azizinamini. 2018. “New connection detail to connect precast column to cap beam using ultra-high-performance concrete in accelerated bridge construction applications.” Transp. Res. Rec. 2672 (41): 207–220. https://doi.org/10.1177/0361198118792766.
Shama, A. A., J. B. Marder, and A. J. Aref. 2002. “Seismic performance and retrofit of steel pile to concrete cap connections.” ACI Struct. J. 99 (1): 51–61.
Sritharan, S., M. T. Suleiman, and D. J. White. 2007. “Effects of seasonal freezing on bridge column-foundation-soil interaction and their implications.” Earthquake Spectra 23 (1): 199–222. https://doi.org/10.1193/1.2423071.
UDOT (Utah Department of Transportation). 2017. Structural design and detail manual. Taylorsville, UT: UDOT.
Wipf, T. J., F. W. Klaiber, S. Hockerman, R. P. Bowers, and M. Becker. 2009. Precast concrete elements for accelerated bridge construction: Laboratory testing of precast substructure components, Boone County bridge, IHRB Project TR-561. Ames, IA: Center for Transportation Research and Education, Iowa State Univ.
Xiao, Y., H. Wu, T. T. Yaprak, G. R. Martin, and J. B. Mander. 2006. “Experimental studies on seismic behavior of steel pile-to-pile-cap connections.” J. Bridge Eng. 11 (2): 151–159. https://doi.org/10.1061/(ASCE)1084-0702(2006)11:2(151).
Information & Authors
Information
Published In
Copyright
© 2020 American Society of Civil Engineers.
History
Received: Oct 21, 2019
Accepted: Mar 13, 2020
Published online: Jun 3, 2020
Published in print: Aug 1, 2020
Discussion open until: Nov 3, 2020
Authors
Metrics & Citations
Metrics
Citations
Download citation
If you have the appropriate software installed, you can download article citation data to the citation manager of your choice. Simply select your manager software from the list below and click Download.