Punching Shear Strength of CFT Bridge Column to Reinforced Concrete Four-Pile Cap Connections
Publication: Journal of Bridge Engineering
Volume 22, Issue 8
Abstract
This paper presents experimental and analytical studies on the punching shear behavior of concrete-filled steel-tube (CFT) bridge column to pile-foundation connections. Five CFT bridge column to reinforced-concrete (RC) four-pile cap connections were constructed and tested under monotonic downward vertical loads to the columns, and the effects of the connection details, including embedment depths of CFT columns, shear studs, face annular rings, and headed shear reinforcement, on punching shear behavior were evaluated. Test results indicate that the connection details significantly affected the cracking patterns of pile caps and the failure modes of connections. The use of shear studs, face annular rings, headed shear reinforcement, and reduced embedment depths of CFT columns can substantially enhance the punching shear strength of CFT column to RC-pile cap connections. The tested specimen with a face annular ring welded onto the CFT column base showed the most favorable punching shear behavior with the highest loading capacity and the most ductile failure mode. On the basis of the experimental observations, the effective depths of pile caps for CFT columns under punching were proposed, and then the punching shear strength of the tested connections was predicted using current design codes for the design of RC footings. A modified empirical strength model was also developed on the basis of experimental and finite-element analysis results.
Get full access to this article
View all available purchase options and get full access to this article.
Acknowledgments
The authors gratefully acknowledge the funding provided by the National Natural Science Foundation of China (Grants 51478459 and 51323004), the China Postdoctoral Science Foundations (Grants 2013M540476 and 2015T80601), and Jiangsu Collaborative Innovation Center for Building Energy Saving and Construction Technology (Grant SJXTY1517). The experimental work described in this article was conducted at the Jiangsu Key Laboratory of Environmental Impact and Structural Safety in Civil Engineering in the China University of Mining and Technology, which is supported by a project funded by the Priority Academic Program Development of Jiangsu Higher Education Institutions (PAPD) [Project Suzhengbanfa (2014)–No.37]. The authors also extend thanks to the staffs and students at the laboratory for their help during test preparation and completion.
References
AASHTO. (2012). LRFD bridge design specifications, 6th Ed., Washington, DC.
Abaqus [Computer software]. SIMULIA, Providence, RI.
ACI (American Concrete Institute). (2014). Building code requirements for structural concrete (ACI 318-14) and commentary (318R-14), Farmington Hills, MI.
Adebar, P., Kuchma, D., and Collins, M. P. (1990). “Strut-and-tie models for the design of pile caps: an experimental study.” ACI Struct. J., 87(1), 81–92.
Cheng, C. T., Chan, C. F., and Chung, L. L. (2007). “Seismic behavior of steel beams and CFT column moment-resisting connections with floor slabs.” J. Constr. Steel Res., 63(11), 1479–1493.
Chou, C. C., and Chen, Y. C. (2006). “Cyclic tests of post-tensioned precast CFT segmental bridge columns with unbonded strands.” Earthquake Eng. Struct. Dyn., 35(2), 159–175.
Deng, Y., Tuan, C. Y., Zhou, Q., and Xiao, Y. (2011). “Flexural strength analysis of non-post-tensioned and post-tensioned concrete-filled circular steel tubes.” J. Constr. Steel Res., 67(2), 192–202.
Deng, Y., and Tuan, C. Y. (2013). “Design of concrete-filled circular steel tubes under lateral impact.” ACI Struct. J., 110(4), 691–702.
Han, L. H. (2007). Concrete-filled steel tubular structures: theory and practice, 2nd Ed., Science Press, Beijing (in Chinese).
Haraldsson, O. S., Janes, T. M., Eberhard, M. O., and Stanton, J. F. (2013). “Precast bent system for high seismic regions: Laboratory tests of column-to-footing socket connections.” Rep. No. FHWA-HIF-13-039, Federal Highway Administration, Washington, DC.
He, W. H., Xiao, Y., Guo, Y. R., and Fan, Y. L. (2013). “Pseudo-dynamic testing of hybrid frame with steel beams bolted to CFT columns.” J. Constr. Steel Res., 88(5), 123–133.
Hegger, J., Ricker, M., and Sherif, A. G. (2009). “Punching strength of reinforced concrete footings.” ACI Struct. J., 106(5), 706–716.
Hsu, H. L., and Lin, H. W. (2006). “Improving seismic performance of concrete-filled tube to base connections.” J. Constr. Steel Res., 62(12), 1333–1340.
Kim, J. W., Lee, C. H., and Kang, T. H. K. (2014). “Shear-head reinforcement for concrete slab to concrete-filled tube column connections.” ACI Struct. J., 111(3), 629–638.
Lee, C. H., Kim, J. W., and Song, J. G. (2008). “Punching shear strength and post-punching behavior of CFT column to RC flat plate connections.” J. Constr. Steel Res., 64(4), 418–428.
Lehman, D. E., and Roeder, C. W. (2012). “Foundation connections for circular concrete-filled tubes.” J. Constr. Steel Res., 78(Nov), 212–225.
Li, X., Xiao, Y., and Wu, Y. T. (2009). “Seismic behavior of exterior connections with steel beams bolted to CFT columns.” J. Constr. Steel Res., 65(7), 1438–1446.
MOHURD (Ministry of Housing and Urban-Rural Development of the People’s Republic of China). (2010). “Code for design of concrete structures.” GB50010-2010, China Industry Press, Beijing.
Sakino, K., Nakahara, H., Morino, S., and Nishiyama, I. (2004). “Behavior of centrally loaded concrete filled steel tube short columns.” J. Struct. Eng., 180–188.
Souza, R., Kuchma, D., Park, J. W., and Bittencourt, T. (2009). “Adaptable strut-and-tie model for design and verification of four-pile caps.” ACI Struct. J., 106(2), 142–150.
Stephens, M. T., Lehman, D. E., and Roeder, C. W. (2015). Concrete-filled tube bridge pier connections for accelerated bridge construction, National Technical Information Service, Springfield, VA.
Xiao, Y., Zhang, Z., Hu, J., Kunnath, S., and Guo, P. X. (2011). “Seismic behavior of CFT column and steel pile footings.” J. Bridge Eng., 575–586.
Xiao, Y., Priestley, M. J. N., and Seible, F. (1996). “Seismic assessment and retrofit of bridge column footings.” ACI Struct. J., 93(1), 79–94.
Information & Authors
Information
Published In
Copyright
© 2017 American Society of Civil Engineers.
History
Received: Jun 7, 2016
Accepted: Jan 27, 2017
Published online: May 17, 2017
Published in print: Aug 1, 2017
Discussion open until: Oct 17, 2017
Authors
Metrics & Citations
Metrics
Citations
Download citation
If you have the appropriate software installed, you can download article citation data to the citation manager of your choice. Simply select your manager software from the list below and click Download.