Review of Transverse Reinforcement Requirements for Precast Load-Bearing Wall Panels with Large Openings under Compression
Publication: Journal of Architectural Engineering
Volume 20, Issue 2
Abstract
Precast concrete load-bearing wall panels have been used for decades with unparalleled success due to their architectural versatility, thermal insulation, ease of production and erection, and structural performance. According to the current building code, structural walls do not need transverse ties if the vertical reinforcement ratio is less than 1% or when vertical reinforcement is not required as compression reinforcement. Also, minimum reinforcement requirements do not apply to structural walls with an average effective prestress of 1,551 kPa (225 psi) or greater. Elimination of transverse ties in structural precast walls simplifies the production of the panels. The presence of large openings in precast walls is very common in the design of modern buildings. This results in a significant reduction of the panel cross section. Most designers tend to design the remaining portion of the panel cross section as a column and not a wall, which requires minimum transverse ties according to the current building code in the United States. The requirement could complicate wall detailing and reduce the efficiency and economy of panel fabrication. This paper summarizes the literature review conducted to determine when precast load-bearing walls should be designed as columns/walls with respect to transverse reinforcement. The requirements of transverse reinforcement in walls and columns in various building codes were studied, and design recommendations were made.
Get full access to this article
View all available purchase options and get full access to this article.
References
American Concrete Institute (ACI). (1999). “Details and detailing of concrete reinforcement.” ACI 315-99, Detroit.
American Concrete Institute (ACI). (2011). “Building code requirements for structural concrete and commentary and commentary.” ACI 318-11, Detroit.
Bresler, B., and Gilbert, P. H. (1961). “Tie requirements for reinforced concrete columns.” ACI J. Proc., 58(5), 555–570.
European Committee for Standardization (CEN). (2004). “Design of concrete structures, part 1.1.” Eurocode 2, Brussels, Belgium.
Hudson, F. M. (1966). “Reinforced concrete columns: Effects of lateral tie spacing on ultimate strength.” ACI Spec. Publ., 13, 235–244.
Japan Society of Civil Engineers (JSCE). (2010). “Standard specifications for concrete structures.” Guidelines for concrete No.15, Tokyo.
Pfister, J. F. (1964). “Influence of ties on the behavior of reinforced concrete columns.” ACI J. Proc., 61(32), 521–537.
Standards Australia International (SAI). (2001). “Australian standard—Concrete structures.” AS 3600-2001 (incorporating amendment No. 1 and amendment No. 2), Sydney, Australia.
Information & Authors
Information
Published In
Copyright
© 2013 American Society of Civil Engineers.
History
Received: Jan 16, 2013
Accepted: Oct 28, 2013
Published online: Oct 30, 2013
Discussion open until: May 31, 2014
Published in print: Jun 1, 2014
Authors
Metrics & Citations
Metrics
Citations
Download citation
If you have the appropriate software installed, you can download article citation data to the citation manager of your choice. Simply select your manager software from the list below and click Download.