CFRP Composite Connector for Concrete Members
Publication: Journal of Composites for Construction
Volume 7, Issue 1
Abstract
Steel plate connections are frequently used in tilt-up and precast concrete building construction to tie adjacent wall panels together for shear and overturning effects, and to provide continuous diaphragm chord connections for wind and seismic loading. These welded connectors perform poorly in regions of high seismicity and are vulnerable to corrosion. Until now, retrofit and repair strategies for in-plane shear transfer strengthening were limited to attaching steel sections across panel edges. In the present paper, an experimental program is described that utilizes carbon fiber reinforced plastic (CFRP) composites to develop a viable retrofit scheme for precast concrete shear walls and diaphragms. Nine full-scale precast wall panel assemblies with CFRP composite connectors have been tested. The results show that the CFRP composite connection is an effective solution for the seismic retrofit and repair of precast concrete wall assemblies and other precast concrete elements, such as horizontal diaphragms, that require in-plane shear transfer strengthening.
Get full access to this article
View all available purchase options and get full access to this article.
References
American Concrete Institute (ACI). (1991). “State-of-the-art report on anchorage to concrete.” Rep. No. ACI 355.1R-91, Detroit.
American Concrete Institute (ACI). (1992). “Tilt-up concrete structures.” Rep. No. ACI 551R-92, Detroit.
American Concrete Institute (ACI). (1993). “Guide for precast concrete wall panels.” Rep. No. ACI 533R-93, Detroit.
American Society of Civil Engineers (ASCE). (2000). “FEMA 356 prestandard and commentary for the scientific rehabilitation of buildings.” Rep., Federal Emergency Management Agency, Washington, D.C.
ASTM. (1995). “Annual book of ASTM standards.” D 3039/D 3039M-95a, Vol. 14.02, West Conshohocken, Pa.
Building Seismic Safety Council. (1997). “FEMA 273 NEHRP guidelines for the seismic rehabilitation of buildings.” Rep., Federal Emergency Management Agency, Washington, D.C.
Chajes, M. J., Finch, W. W., Januszka, T. F., and Thomson, T. A.(1996). “Bond and force transfer of composite material plates bonded to concrete.” ACI Struct. J., 93(2), 208–217.
Chakrabarti, S. C., Nayak, G. C., and Paul, D. K.(1988). “Shear characteristics of cast-in-place vertical joints in story high precast wall assembly.” ACI J., 85(1), 30–45.
Dolan, C. W., Stanton, J. F., and Anderson, R. G.(1987). “Moment resistant connections and simple connections.” PCI J., 32(2), 62–74.
Englekirk, R. E.(1986). “Overview of PCI workshop on the effective use of precast concrete for seismic resistance.” PCI J., 31(6), 48–58.
Fintel, M.(1995). “Performance of buildings with shear walls in earthquakes of the last thirty years.” PCI J., 40(3), 62–80.
Gergely, I., and Pantelides, C. P. (1998). “Design aid for shear strengthening of reinforced concrete T-joints using carbon fiber reinforcedplastic composites.” Research Rep. UUCE 98-02, NTIS No. PB98-158504, Univ. of Utah, Salt Lake City.
Hamburger, R. O., McCormick, D. L., and Hom, S.(1988). “The Whittier Narrows, California earthquake of October 1, 1987—Performance of tilt-up buildings.” Earthquake Spectra, 4(2), 219–254.
Hofheins, G. L., Reaveley, L. D., and Pantelides, C. P.(2002). “Behavior of welded plate connections in precast concrete panels under simulated seismic loads.” PCI J., 47(4), 122–133.
McMullin, P. W. (2000). “Connection of precast shear wall panels using carbon fiber composites and adhesive anchor bolts.” MS thesis, Univ. of Utah, Salt Lake City.
Oliva, M. G., and Shahrooz, B. M. (1984). “Shaking table tests of wet jointed precast wall panels.” Proc., 8th World Conf. on Earthquake Engineering, Vol. VI, 717–724.
Pall, A. S., Marsh, C., and Fazio, P.(1980). “Friction joints for seismic control of large panel structures.” PCI J., 25(6), 38–61.
Pantelides, C. P., Volnyy, V. A., Gergely, J., and Reaveley, L. D. (2002). “Retrofit of precast concrete panel connections with carbon fiber composites.” PCI J., in press.
PCI handbook, 5th Ed. (1999). Precast Concrete Institute, Chicago.
Pincheira, J. G., Oliva, M. G., and Kusumo-Rahardjo, F. I. (1998). “Tests on double tee flange connectors subjected to monotonic and cyclic loading.” PCI J., 43(3), 82–96.
Precast Concrete Institute (PCI) Ad Hoc Committee on Precast Walls. (1997). “Design for lateral force resistance with precast concrete shear walls.” PCI J., 42(5), 44–63.
Precast Concrete Institute (PCI) Committee on Building Code and PCI Technical Activities Committee. (1986). “Proposed design requirements for precast concrete.” PCI J., 31(6), 32–47.
Soudki, K. A., Rizkalla, S. H., and Daikiw, R. W.(1995). “Horizontal connections for precast concrete shear walls subjected to cyclic deformations. Part 2: Prestressed connections.” PCI J., 40(5), 82–96.
Soudki, K. A., West, J. S., Rizkalla, S. H., and Blackett, B.(1996). “Horizontal connections for precast concrete shear wall panels under cyclic shear loading.” PCI J., 41(3), 64–80.
Tilt-up load-bearing walls, 3rd Ed. (1994). Portland Cement Association, Skokie, Ill.
Velkov, M., Ivkovish, M., and Perishich, Z. (1984). “Experimental and analytical investigation of prefabricated large panel systems to be constructed in seismic regions.” Proc., 8th World Conf. on Earthquake Engineering, Vol. VI, 737–780.
Volnyy, V. A., and Pantelides, C. P.(1999). “Bond length of CFRP composites attached to precast concrete walls.” J. Compos. Constr., 3(4), 168–176.
Information & Authors
Information
Published In
Copyright
Copyright © 2003 American Society of Civil Engineers.
History
Received: Apr 24, 2001
Accepted: Feb 13, 2002
Published online: Jan 15, 2003
Published in print: Feb 2003
Authors
Metrics & Citations
Metrics
Citations
Download citation
If you have the appropriate software installed, you can download article citation data to the citation manager of your choice. Simply select your manager software from the list below and click Download.