Optimizing Structural Response of Beams Strengthened with GFRP Plates
Publication: Journal of Composites for Construction
Volume 2, Issue 2
Abstract
This paper addresses the structural implications when a glass fiber reinforced plastic (GFRP) plate is bonded externally to a reinforced concrete (RC) beam for flexural strengthening. Full-scale beams were tested in the laboratory to identify the differences in behavior of a GFRP-plated RC beam from that of a steel-plated one, and then special design techniques were developed to enhance the utilization of the GFRP plate material. The design technique that was adopted improves the ultimate load capacity of the strengthened composite beam and enhances its ductility in terms of deflection at midspan, energy absorption capacity, and curvature in the pure bending region. Preservation of the plate-adhesive-concrete interface bond and strengthening the compression concrete by confinement through the use of bonded plates onto the beam web are two critical features of this design approach. Experimental observations indicate that there is a limiting thickness to the compression plate beyond which premature bond failure may occur. An analytical model to predict the failure load of the strengthened composite beam is presented that shows good agreement with the test results and confirms that plates effectively bonded to confine the compression concrete make an effective contribution to the composite beam strength, stiffness, and ductility.
Get full access to this article
View all available purchase options and get full access to this article.
References
1.
Bank, L. C., and Xi, Z. (1995). “Punching shear behavior of pultruded FRP grating reinforced concrete slabs.”Non-metallic (FRP) reinforcement for concrete structures, L. Taerwe, ed., RILEM Proceedings 29, E & FN Spon, London, 360–367.
2.
“Building code requirements for reinforced concrete (ACI 318-95).” (1995). ACI Committee 318, American Concrete Inst., Detroit, Mich.
3.
Bencardino, F., Spadea, G., and Swamy, R. N. (1996). “Use of non-metallic reinforcements for strengthening and rehabilitating new and deteriorating structures.”Int. Conf. on Mat. Engrg., Lecce, Italy, 1105–1192.
4.
“Design of concrete structures. part 1. general rules and rules for buildings.” (1992). Eurocode 2, British Standards Inst., DD ENV 1992-1-1.
5.
Hobbs, B., Swamy, R. N., and Roberts, M. (1996). “Corrosion performance of steel-plated reinforced concrete beams after long-term natural exposure.”ACI Publication, SP-165, American Concrete Inst., Detroit, Mich., 101–126.
6.
Mufti, A. A., Newhook, J. P., and Tadros, G. (1996). “Deformability versus ductility in concrete beams with FRP reinforcement.”Advanced composite materials in bridges and structures, M. El-Badry, ed., Canadian Society for Civil Engineering, 189–199.
7.
Naaman, A. E, and Jeong, S. M. (1995). “Structural ductility of concrete beams prestressed with FRP tendons.”Non-metallic (FRP) reinforcement for concrete structures, L. Taerwe, ed., RILEM Proceedings 29, E & FN Spon, London, 379–386.
8.
Nanni, A. (1992). “State-of-the-art report on FRP reinforcement in civil engineering concrete structures (highway bridges emphasis).” Florida Dept. of Transp., Tallahassee, Fla. March 12.
9.
Saadatmanesh, H., and Ehsani, M. R.(1991). “RC beams strengthened with GFRP plates. I: experimental study.”J. Struct. Engrg., 117(11), 3417–3433.
10.
Sharif, A., Al-Sulaimani, G. J., Basunbul, I. A., Baluch, M. H., and Ghaleb, B. N. (1994). “Strengthening of initially loaded reinforced concrete beams using FRP plates.”ACI Struct. J., March–April, 160–168.
11.
Spadea, G., Bencardino, F., and Swamy, R. N. (1997). “Strengthening and upgrading structures with bonded CFRP sheets—design aspects for structural integrity.”Non-metallic (FRP) reinforcement for concrete structures, Vol. 1, Japan Concrete Inst., 629–636.
12.
“Structural use of concrete: code of practice for design and construction.” (1985). BS 8110: Part 1, British Standards Inst., London, England.
13.
Swamy, R. N. (1996). “Adhesive bonding in construction technology.”Advanced technology for design and fabrication of composite materials and structures. Kluwer Academic Publishers Group, Boston, Mass., 15–30.
14.
Swamy, R. N., and Mukhopadhyaya, P. (1995b). “Role and effectiveness of non-metallic plates in strengthening and upgrading concrete structures.”Non-metallic (FRP) reinforcement for concrete structures, L. Taerwe, ed., RILEM Proceedings 29, E & FN Spon, London, 473–482.
15.
Swamy, R. N., Hobbs, B., and Roberts, M. (1995a). “Structural behavior of externally bonded steel plated reinforced concrete beams after long-term natural exposure.”The Struct. Engr., 73(16) Aug., 255– 261.
16.
Swamy, R. N., Jones, R., and Bloxham, J. W.(1987). “Structural behavior of reinforced concrete beams strengthened by epoxy-bonded steel plates.”The Struct. Engr., 65A(2), 1987, 59–68; also 65A (4), 1987, 150.
17.
Swamy, R. N., Lynsdale, C. J., and Mukhopadhyaya, P. (1996). “Effective strengthening with ductility: use of externally bonded plates of non-metallic composite materials.”Advanced composite materials in bridges and structures. M. El-Badry, ed., Canadian Society for Civil Engineering, 481–488.
18.
Swamy, R. N., Mukhopadhyaya, P., and Lynsdale, C. (1997). “Ductility considerations in using GFRP sheets to strengthen and upgrade structures.”Non-metallic (FRP) reinforcement for concrete structures, Vol. 1, Japan Concrete Inst., 637–644.
Information & Authors
Information
Published In
Copyright
Copyright © 1998 American Society of Civil Engineers.
History
Published online: May 1, 1998
Published in print: May 1998
Authors
Metrics & Citations
Metrics
Citations
Download citation
If you have the appropriate software installed, you can download article citation data to the citation manager of your choice. Simply select your manager software from the list below and click Download.