Seismic Performance of Multisimple-Span Bridges Retrofitted with Link Slabs
Publication: Journal of Bridge Engineering
Volume 7, Issue 2
Abstract
During earthquakes multisimple-span bridges are vulnerable to span separation at their expansion joints. A common way of preventing unseating of spans is to have cable or rod restrainers that provide connections between adjacent spans. Alternatively, dislocation of the girders can be controlled with a link slab that is the continuous portion of the bridge deck between simple spans. Seismic retrofit with link slab should be more cost-effective than the existing methods when it is performed during redecking or removal of expansion joints. Maintenance cost associated with expansion joints could also be reduced. This paper discusses the use of link slabs for retrofit of seismically deficient multisimple-span bridges with precast, prestressed concrete girders. The concept is equally applicable to bridges with steel girders. Analytical studies for typical overpasses were performed to investigate the effectiveness of the proposed link slab application. A simple preliminary design procedure was also developed.
Get full access to this article
View all available purchase options and get full access to this article.
References
AASHTO. (1996). Standard bridge specifications for highway bridges, 16th. Ed., Washington, DC.
AASHTO. (1998). LRFD bridge design specifications, 2nd Ed., Washington, D.C., 5–40.
AASHTO. (2000). Guide specifications for seismic isolation design, Washington, D.C.
American Concrete Institute (ACI) Committee 544. (1996). “Fiber reinforced concrete.” ACI 544.1R-96 Farmington Hills, Mich.
Caner, A. (1996). “Analysis and design of jointless bridge decks supported by simple span girders.” PhD dissertation, North Carolina State Univ., Raleigh, N.C.
Caner, A., and Zia, P.(1998). “Behavior and design of link slabs for jointless bridge decks,” PCI J., 43(3), 68–80.
Chen, W. F., and Duan, L. (2000). “Earthquake damage to bridges.” Bridge engineering handbook, J. P. Moehle and M. O. Eberhard, eds., CRC, Boca Raton, Fla., 34/1–34/33.
Cooper, J. D., and Buckle, I.(1995). “Lessons from the Kobe Quake,” Public Roads, 59(2), 28–37.
Cooper, J. D., Friedland, I. M., Buckle, I. G., Nimis, R. G., and Bobb, N. M.(1994). “The Northridge earthquake: Progress made, lessons learned in seismic resistant bridge design,” Public Roads, 58(1), 40–48.
Dogan, E., Hill, H., and Krstulovic-Opara, N. (2000). “Suggested design guidelines for seismic retrofit with SIMCON and SIFCON.” High performance fiber-reinforced concrete in infrastructural repair and retrofit, SP-185, American Concrete Institute, Farmington Hills, Mich., 207–248.
El-Safty, A. K. (1994). “Analysis of jointless bridge decks with partially debonded simple span beams.” PhD dissertation, North Carolina State Univ., Raleigh, N.C.
Federal Highway Administration (FHWA). (1995). “Seismic retrofitting manual for highway bridges.” Report No. FHWA-RD-94-052, McLean, Va.
Feng, M. Q., Kim, J. M., Shinozuka, M., and Purasinghe, R.(2000). “Viscoelastic dampers at expansion joints for seismic protection of bridges,” J. Bridge Eng., 1(5), 67–74.
Gastal, F. (1986). “Instantaneous and time-dependent response and strength of jointless bridge beams.” PhD dissertation, North Carolina State Univ., Raleigh, N.C.
Ghasemi, H., Otsuka, H., Cooper, J. D., and Nakajima, H.(1996). “Aftermath of the Kobe earthquake,” Public Roads, 60(2), 17–22.
Iverson, J. K., and Pfeifer, D. W. (1986). “New PCI bearing pad design recommendations.” Joint sealing and bearing systems for concrete structures, SP-94, 1, American Concrete Institute, Farmington Hills, Mich., 233–246.
Krstulovic-Opara, N., LaFave, J. M., Dogan, E., and Uang, C.-M. (2000). “Seismic retrofit with discontinuous slurry infiltrated mat concrete (SIMCON) jackets.” High performance fiber-reinforced concrete in infrastructural repair and retrofit, SP-185, American Concrete Institute, Farmington Hills, Mich., 141–185.
LARSA user’s manual; version 4.1. (1991). Larsa Inc., New York.
Osterle, R. G., Glikin, J. D., and Larson, S. C. (1989). “Design of precast, prestressed bridge girder made continuous.” NCHRP Report 322, National Research Council, Washington, D.C.
Priestley, M. J. N., Seible, F., and Calvi, G. M. (1996). Seismic design and retrofit of bridges, Wiley, New York.
Selna, L. G., Malvar, L. J., and Zelinski, R. J.(1989). “Bridge retrofit testing: Hinge cable restrainers,” J. Bridge Eng., 115(4), 920–934.
Todd, D., et al. (1994). “1994 Northridge earthquake performance of structures, lifelines, and fire protection systems,” NIST Special Publication 862, ICSSC TR14, Washington, D.C.
Yashinsky, M.(1998). “Performance of bridge seismic retrofits during Northridge earthquake,” J. Bridge Eng., 3(1), 1–14.
Youd, L. T., Bardet, J. P., and Bray, J. D. (2000). “Kocaeli, Turkey, earthquake of August 17, 1999 reconnaissance report,” Earthquake Spectra, 2000-03, Earthquake Engineering Research Institute, Oakland, Calif.
Zia, P., Caner, A., and El-Safty, A, K. (1995). “Jointless bridge decks.” Research Report No. FHWA/NC/95-006, Center for Transportation Engineering Studies, North Carolina State Univ., Raleigh, N.C.
Information & Authors
Information
Published In
Copyright
Copyright © 2002 American Society of Civil Engineers.
History
Received: Nov 14, 2000
Accepted: Jun 29, 2001
Published online: Mar 1, 2002
Published in print: Mar 2002
Authors
Metrics & Citations
Metrics
Citations
Download citation
If you have the appropriate software installed, you can download article citation data to the citation manager of your choice. Simply select your manager software from the list below and click Download.