A state of the practice summary is presented with regard to the design of architectural glazing to resist earthquakes. Highlighted are new model building code provisions that have been adopted recently by a number of code bodies including the 2003 International Building Code and the 2002 NFPA 5000 Building Code. These model building codes reference seismic design provisions for architectural glazing in ASCE 7-02 and industry-accepted seismic test methods for architectural glazing developed and published by the American Architectural Manufacturers Association. Designers, specifiers, building owners, and glazing system manufacturers need to be aware of these significant changes in the way architectural glazing components are to be designed and tested for earthquake resistance.

Get full access to this article

View all available purchase options and get full access to this article.

Acknowledgments

The writer is grateful to Dr. Ali Memari and Mr. Paul Kremer from the Architectural Engineering Department at The Pennsylvania State University for their able contributions during the preparation of this paper.

References

American Architectural Manufacturers Association (AAMA). (2001a). “Recommended static test method for evaluating curtain wall and storefront systems subjected to seismic and wind induced interstory drifts.” Publication No. AAMA 501.4-01.
American Architectural Manufacturers Association (AAMA). (2001b). “Recommended dynamic test method for determining the seismic drift causing glass fallout from a wall system.” Publication No. AAMA 501. 6-01.
ASCE. (2002). “Minimum design loads for buildings and other structures.” ASCE 7-02, Reston, Va.
Behr, R. A. (1998). “Seismic performance of architectural glass in mid-rise curtain wall.” J. Archit. Eng., 4(3), 94–98.
Behr, R. A., Belarbi, A., and Brown, A. T. (1995a). “Seismic performance of architectural glass in storefront wall system.” Earthquake Spectra, 11(3), 367–391.
Behr, R. A., Belarbi, A., and Culp, J. H. (1995b). “Dynamic racking tests of curtain wall glass elements with in-plane and out-of-plane motions.” Earthquake Eng. Struct. Dyn., 24(1), 1–14.
Brueggeman, J. L., Behr, R. A., Wulfert, H., Memari, A. M., and Kremer, P. A. (2000). “Dynamic racking performance of an earthquake-isolated curtain wall system.” Earthquake Spectra, 16(4), 735–756.
Building Seismic Safety Council (BSSC). (2001). “2000 NEHRP recommended provisions for seismic regulations for new buildings and other structures, Part 1: Provisions.” FEMA 368, Building Seismic Safety Council, Washington, D.C.
Deschenes, J. P., Behr, R. A., Pantelides, C. P., and Minor, J. E. (1991). “Dynamic racking performance of curtain wall elements.” Technical Rep. Prepared for Monsanto Chemical Company, Saflex Division, and Robertson/Cupples Company of St. Louis, Mo. NTIS Accession No. PB92-140631, St. Louis.
Earthquake Engineering Research Institute (EERI). (1990). “Loma Prieta Earthquake reconnaissance report.” Earthquake Spectra, Rep. Supplement to Volume 6, Oakland, Calif.
Earthquake Engineering Research Institute (EERI). (1995a). ”Northridge Earthquake reconnaissance report.” Earthquake Spectra, Rep. Supplement to Volume 11, Oakland, Calif.
Earthquake Engineering Research Institute (EERI). (1995b). “The Hyogo-Ken Nanbu Earthquake January 17, 1995.” Preliminary Reconnaissance Rep. No. 95-04, Oakland, Calif.
Earthquake Engineering Research Institute (EERI). (2001). “The Nisqually, Washington Earthquake February 28, 2001.” Preliminary Reconnaissance Rep. No. EERI 2001-01, Oakland, Calif.
Evans, D., Kennett, E., Holmes, W. T., and Ramirez, F. J. L. (1998). “Glass damage in the September 19, 1985 Mexico City Earthquake.” Rep. No. CES-861093 Prepared for NSF, Washington, D.C.
International Code Council (ICC). (2002). International building code (IBC) 2003, Country Club Hills, Ill.
Memari, A., Behr, R. A., and Kremer, P. A. (2003). “Seismic behavior of curtain walls containing insulating glass units.” J. Archit. Eng., 9(2), 70–85.
Memari, A., Behr, R. A., and Kremer, P. A. (2004). “Dynamic racking crescendo tests on architectural glass fitted with anchored pet film.” J. Archit. Eng., 10(1), 5–14.
Memari, A., Kremer, P. A., and Behr, R. A. (2006). “Architectural glass panels with rounded corners to mitigate earthquake damage.” Earthquake Spectra, in press.
National Fire Protection Association (NFPA). (2002). NFPA 5000 building code, Quincy, Mass.
Pantelides, C. P., and Behr, R. A. (1994). “Dynamic in-plane racking tests of curtain wall glass elements.” Earthquake Eng. Struct. Dyn., 23, 211–228.
Sakamoto, I. (1978). “Seismic performance of nonstructural and secondary structural elements.” Rep. No. EERC-78/10, Univ. of California, Berkeley, Calif.
Sakamoto, I., Itoh, H., and Ohashi, Y. (1984). “Proposals for aseismic design method on nonstructural elements.” Proc., 8th World Conf. on Earthquake Engineering, Vol. 5, San Francisco, 1093–1100.
Thurston, S. J., and King, A. B. (1992). “Two-directional cyclic racking of corner curtain wall glass elements.” Study Rep. No. 44, Building Research Association of New Zealand (BRANZ), New Zealand.
Wang, M. L., Sakamoto, I., and Bassler, B. L. (1992). “Design of cladding for earthquakes.” Cladding, Chap. 4, Council on Tall Buildings and Urban Habitat, McGraw-Hill, New York, 82–84.
Zarghamee, M. S., Schwartz, T. A., and Gladstone, M. (1996). “Seismic behavior of structural silicone glazing.” Science and technology of building seals, sealants, glazing and waterproofing, ASTM STP 1286, J. C. Myers, ed., Vol. 6, American Society for Testing and Materials, Philadelphia, 46–59.

Information & Authors

Information

Published In

Go to Journal of Architectural Engineering
Journal of Architectural Engineering
Volume 12Issue 3September 2006
Pages: 122 - 128

History

Received: May 6, 2004
Accepted: Jul 21, 2004
Published online: Sep 1, 2006
Published in print: Sep 2006

Permissions

Request permissions for this article.

Authors

Affiliations

Richard A. Behr, F.ASCE
P.E.
Professor and Head, Architectural Engineering Dept., The Pennsylvania State Univ., 104 Engineering Unit A, University Park, PA 16802. E-mail: [email protected]

Metrics & Citations

Metrics

Citations

Download citation

If you have the appropriate software installed, you can download article citation data to the citation manager of your choice. Simply select your manager software from the list below and click Download.

Cited by

View Options

Get Access

Access content

Please select your options to get access

Log in/Register Log in via your institution (Shibboleth)
ASCE Members: Please log in to see member pricing

Purchase

Save for later Information on ASCE Library Cards
ASCE Library Cards let you download journal articles, proceedings papers, and available book chapters across the entire ASCE Library platform. ASCE Library Cards remain active for 24 months or until all downloads are used. Note: This content will be debited as one download at time of checkout.

Terms of Use: ASCE Library Cards are for individual, personal use only. Reselling, republishing, or forwarding the materials to libraries or reading rooms is prohibited.
ASCE Library Card (5 downloads)
$105.00
Add to cart
ASCE Library Card (20 downloads)
$280.00
Add to cart
Buy Single Article
$35.00
Add to cart

Get Access

Access content

Please select your options to get access

Log in/Register Log in via your institution (Shibboleth)
ASCE Members: Please log in to see member pricing

Purchase

Save for later Information on ASCE Library Cards
ASCE Library Cards let you download journal articles, proceedings papers, and available book chapters across the entire ASCE Library platform. ASCE Library Cards remain active for 24 months or until all downloads are used. Note: This content will be debited as one download at time of checkout.

Terms of Use: ASCE Library Cards are for individual, personal use only. Reselling, republishing, or forwarding the materials to libraries or reading rooms is prohibited.
ASCE Library Card (5 downloads)
$105.00
Add to cart
ASCE Library Card (20 downloads)
$280.00
Add to cart
Buy Single Article
$35.00
Add to cart

Media

Figures

Other

Tables

Share

Share

Copy the content Link

Share with email

Email a colleague

Share